When you use OT-PLC602, please follow the below tips as a reference, in order to reduce the fault in the process of
using and the inspection work.
1. The device supports auto-negotiation allocation master and slave. It also can be set master-slave side and grouped
by software. Each group (one point to multi-point communications group) only allows one Master, others are Slaves.
Otherwise, the network data won't be able to transmit. And Master unit should be installed in the local side.
2. Signal transmission cable must be the copper cable. Other material cables will cause the decrease of signal
transmission quality and distance.
3. Long distance cable connection must be formal connection methods, such as welding or using connectors.
4. Coaxial cable, twisted-pair cable, telephone line and power line all can be used to transmit network data signal in
projects. A variety of cables arbitrary mixed connection also can reduce the quality of signal.
5. Please choose matching power supply
(12VDC / 1A).
6. If need to transmit power at the same time, you should install power filter in the front of each device to make sure
signal stability.
7. There is no waterproof design for this product, please make sure it is used in dry environment.
8. If device fails, do not disassemble or repair it by yourself. Please contact us timely.
: Specifications are subject to change without notice. Thank you for choosing us.