The

 

specific

 

size

 

of

 

cylinder(s)

 

to

 

be

 

used

 

with

 

this

 

gas

 

fireplace

 

is

 

recommended

 

not

 

to

 

be

 

below

 

or

 

exceed

 

20

 

lbs.

 

(9

 

kg)

 

capacity.

  

Ensure

 

cylinder

 

is

 

secured,

 

upright,

 

on

 

a

 

level

 

non

combustible

 

base.

 

 

If

 

a

 

larger

 

TC

 

or

 

DOT

 

cylinder

 

is

 

to

 

be

 

used.

  

Ensure

 

that

 

the

 

cylinder

 

is

 

safely

 

secured,

 

upright

 

on

 

a

 

non

combustible

 

base,

 

located

 

a

 

minimum

 

of

 

10ft

 

from

 

the

 

fireplace

 

and

 

in

 

a

 

ventilated

 

space.

  

 

Do

 

not

 

place

 

a

 

propane

 

cylinder

 

for

 

use

 

with

 

this

 

appliance

 

on

 

a

 

non

combustible

 

base

 ‐ 

even

 

snow.

  

Snow

 

around

 

the

 

base

 

of

 

the

 

cylinder

 

foot

 

ring

 

could

 

melt

 

and

 

the

 

cylinder

 

could

 

fall

 

over

 

delivering

 

liquid

 

propane

 

to

 

the

 

unit.

 

 

Do

 

not

 

connect,

 

activate

 

or

 

disconnect

 

this

 

fireplace

 

to

 

a

 

propane

 

cylinder

 

anytime

 

while

 

consuming

 

alcohol.

  

Failure

 

to

 

do

 

so

 

could

 

result

 

in

 

fire

 

causing

 

bodily harm or loss of life.

Inspect

 

the

 

hose

 

assembly

 

for

 

damage

 

prior

 

to

 

each

 

use.

 

If

 

the

 

hose

 

is

 

damaged

 

or

 

there

 

are

 

signs

 

of

 

excessive

 

abrasion

 

or

 

wear

 

replace

 

the

 

hose.

 

 

Use

 

only

 

the

 

pressure

 

regulator

 

and

 

hose

 

assembly

 

supplied

 

with

 

the

 

appliance.

 

Replace

 

the

 

regulator

 

hose

 

assembly

 

only

 

with

 

part

 

number

 

UFP

 

LP12

08

 

these

 

are

 

available

 

only

 

from

 

approved

 

dealer

 ‐

OR

Urban

 

Fire.

  

Содержание 2

Страница 1: ... the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier URBAN FIRE 2 Propane Natural Gas Outdoor Gas Fireplace Installation and Operating Instructions WARNING Improper installation adjustment alteration service or maintenance can cause injury or property da...

Страница 2: ...8 Leak Testing 9 INSTALLATION Installation Safety Notes 10 Initial Firing 11 Minimum Clearances 11 Installation and Tank Assembly 12 Glass Placement 13 Natural Gas Conversion 14 15 MAINTENANCE Maintenance Safety 16 Recommended Service 16 Burner Cleaning 16 Trouble Shooting 17 Replacement Parts 18 Warranty 19 20 Urban Fire Corp 103 South Belair Drive Woodbridge Ontario L4H 2N4 Canada 1 888 337 4989...

Страница 3: ...u hr 8 79 kW MAXIMUM GAS INLET SUPPLY PRESSURE Minimum LPG 11 w c 2 74 kPa Minimum NG 7 w c 1 744 kPa AIR SHUTTER SETTING Adjustable from fully closed to fully open ORIFICE SIZE 0 2000 42 DMS LPG 34 DMS NG Clearances to combustibles Sides Floor Ceiling 36 91 44 cm 0 72 183 cm Urban Fire 2 can be placed on a combustible base ...

Страница 4: ...led by a licensed plumber or a licensed gas fitter Failure to comply will void the warranty 36 W x 36 L x 16 H The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psi 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual...

Страница 5: ...e the hose may be subjected to accidental damage Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition Young children should be carefully supervised when they are in the area of the appliance Keep cover of the fireplace secured on the appliance when not it use to prevent children from playing touching or eating the...

Страница 6: ...be removed when burner is in operation This appliance is equipped with a piezo electric ignition device Be aware and look for proof of ignition spark If there is not ignition spark replace piezo ignitor device OR light pilot manually ...

Страница 7: ...ble base even snow Snow around the base of the cylinder foot ring could melt and the cylinder could fall over delivering liquid propane to the unit Do not connect activate or disconnect this fireplace to a propane cylinder anytime while consuming alcohol Failure to do so could result in fire causing bodily harm or loss of life Inspect the hose assembly for damage prior to each use If the hose is d...

Страница 8: ...ecting and removing the gas cylinder from the appliance always be sure to adhere to the following items Check that the gas control valve on the appliance as well as on the cylinder are turned off before disconnecting the gas line from the cylinder Never smoke or have an open flame in the vicinity of the gas appliance or gas cylinder When connection a new gas supply cylinder be sure to tighten all ...

Страница 9: ...the solution to the gas line and to each connection If bubbles form this means that there is a leak is present Tighten any connections that may be loose and leak test again If no more leaks are found use the appliance If leaks persist and cannot be stopped turn off the gas supply and contact your distributor or local gas service technician for assistance To check for leaks on the hose soak cloth w...

Страница 10: ...allation This outdoor fireplace and its components are tested and safe when installed in accordance with this installation manual UNPACKING Please check the appliance carefully for any damaged or missing components Report any problems to your dealer within 30 days of purchase MINIMUM CLEARANCES The minimum clearance to combustibles for the sides and the top is 36 914 mm This outdoor fireplace is s...

Страница 11: ...th your appliance Loosen the screw which holds the aeration adjustment shutter in place and rotate the adjustment shutter to increase or decrease primary air see below and tighten the screw Increasing the primary air will cause the flame to appear more transparent and blue Decreasing the primary air will cause the flames to appear more yellow or orange Evaluate the aeration only after the unit has...

Страница 12: ...ION k all the item outside in fi t of clearan on a level b pane place c ABOVE Tan safety gas hose and e hose to cy TA ms from the inal position nce from the ase cylinder upri nk should be d tank is pos ylinder ANK A e box Urban n There mus e side of the ight inside t secure and sitioned awa ASSE n Fire come st be a mini e table to an he tank hold pressed int ay from foot EMBL s fully mum of ny der...

Страница 13: ...Page 13 of 22 ...

Страница 14: ...rger opening orifice tip 6 Reattach converted orifice to supporting bracket with nut Leak check with a soap and water solution 1 Using two adjustable wrenches disconnect propane hose 3 8 flare fitting and propane pilot regulator as shown above Using gas pipe compound attach Natural Gas pilot regulator and 3 8 flare fitting ...

Страница 15: ...he top side of the pilot assembly This will allow you to access the pilot assembly Take an adjustable wrench and loosen the pilot flame counter clockwise This will allow you access to the pilots orifice 8 Slide tab to Natural Gas position slightly larger hole Re fasten pilot flame with wrench clockwise Soap check ...

Страница 16: ...y supplied RECOMMENDED SERVICE Visually check the burner flame occasionally Have the appliance inspected annually by a professional service technician Clean the appliance regularly BURNER CLEANING Periodic cleaning is necessary for proper operation Remove the orifice and check that the burner orifice is clean If the orifice is plugged disassembly may be required to remove any foreign material from...

Страница 17: ...fective igniter 5 Replace igniter 6 Poor grounding of igniter 6 Tighten igniter line to igniter 7 Whistle noise from pilot 7 Ensure pilot is converted to correct gas 8 Whistle noise from burner tube 8 Point burner tube below burner outlet holes B No gas or low gas pressure 1 Gas line shut off 1 Turn on shut off valves 2 Air in gas lines 2 Purge gas lines 3 Gas lines may not be connected 3 Connect ...

Страница 18: ...t Parts When requesting service or replacement parts for your unit please provide model name and serial number All parts listed above may be ordered from an authorized dealer or by calling Urban Fire customer service at 1 888 337 4989 x 3 ...

Страница 19: ...Page 19 of 22 Please register your product immediately at www urbanfire ca or call 1 888 337 4989 x 3 ...

Страница 20: ...Page 20 of 22 ...