MAINTENANCE
MAINTENANCE SAFETY
Turn off the gas to the main burner and allow the fireplace to cool for 30 minutes before
servicing.
Service and repair should be done by a qualified service person. The appliance should be inspected
before use and at least annually by a qualified service technician. It is important that the access door
compartment and burner be kept clean to provide for adequate combustion and ventilation airflow.
Do not substitute materials or use components other than factory supplied.
RECOMMENDED SERVICE
Visually check the burner flame occasionally.
Have the appliance inspected annually by a professional service technician.
Clean the appliance regularly.
BURNER CLEANING
Periodic cleaning is necessary for proper operation.
Remove the orifice, and check that the burner orifice is clean. If the orifice is plugged, disassembly
may be required to remove any foreign material from the orifice or tubing.
Visually inspect the burner before each use of the appliance. Inspect the burner Brush or blow away
any dust, glass, or foreign debris from burner holes. If the burner is found to be corroded or
damaged, the burner must be replaced prior to the appliance being put into operation. (see page 6)
.
.