background image

E

n

g

li

sh

En

g

li

sh

  - M

an

u

al

 c

od

e: 

11

9

G

9

1

4

1

11

9

G

9

1

4

1

 ve

r.

 

33

  0

2

/2

0

15   © U

R

B

A

C

O

 S

.A

. - T

h

e d

ata a

n

d i

nf

or

m

ati

on r

ep

orte

d i

n th

is

 in

sta

lla

tio

n m

an

u

al

 a

re s

u

sc

ep

tib

le to c

h

an

g

e at a

ny ti

m

e a

n

d w

ith

ou

t o

b

lig

ati

on

 o

n U

R

B

A

C

O

 s.a. to n

otify u

se

rs.

URBACO SA

ZA du Couquiou
84320 ENTRAIGUES -FRANCE
www.urbaco.com

Содержание Luxor CC6U200PR

Страница 1: ...Luxor Luxor Technical Centre Technical Centre Installation Use Maintenance Installation Use Maintenance English EN ...

Страница 2: ...echnical centre Pneumatic performances Pag 5 5 Control panel Pag 6 5 1 Summary table of accessories power demands Pag 7 5 2 Electrical connections Pag 8 5 3 Release discharge the system from inside the centre Pag 8 6 Technical centre installation Pag 10 6 1 Preliminary checks Pag 10 6 2 Fastening to the floor with reinforcement optional Pag 11 7 Connecting additional devices Pag 12 7 1 Cooling fan...

Страница 3: ...an be used only for purposes indicated in this manual The use of this product for purposes other than those described above and installation executed in a manner other than as in structed in this technical manual are prohibited Urbaco has no responsibility for any improper use of the system 2 1 Intended use Do not allow children to play or loiter within the movement area of the bollard Keep transm...

Страница 4: ... to change at any time and without obligation on URBACO S A to notify users English EN 1 Compressor group unit 2 Control panel 3 Magnetic loops optional 4 Hot Cold thermostats optional 5 Cooling fans optional 6 Heating unit optional 7 Automatic purge optional with timer 8 Floor mounting basement optional 9 Air joints for bollards Ø 10 10 Air circuit discharge 11 Pressure regulator manometer 4 2 Te...

Страница 5: ...e values if T 25 C and compressor duty cycle of up to 40 The no of manoeuvres should be evenly distributed over time The conduit length has influence on the max no of manoeuvres per hour For intensive use manoeuvres the use the aeration kit is required Minimal interval between two subsequent manoeuvres s No of bollards Ø 200 Ø 270 Ø 320 h 600 h 800 h 600 h 800 h 600 h 800 1 35 50 35 50 35 50 2 80 ...

Страница 6: ...bled DIP n 4 Programming see table below DIP n 5 Table of fuses Fuse for accessories 5A Fuse for main line 630 mA Fuse for control board 1A Fuse for compressor 8A T Switch Button Led Option N 4 N 5 CH1 CH2 After 5 ON ON ON It enables the bistable solenoid valve ON ON OFF It enables the monostable solenoid valve ON ON ON It enables the acoustic signaller and the flashing of the red traffic light ON...

Страница 7: ... valve Total power W if with bistable solenoid valve Monostable solenoid valve 8 6 48 Bistable solenoid valve 3 8 24 Duty cycle 3 6 18 8 24 Flashing light 25 2 50 50 Traffic light 11 4 44 44 Magnetic loop 2 5 6 15 15 Total W 131 125 113 117 U200 control panel two U201 boards to control 3 separated access ways Type of accessory Single accessory power W Max no of connectable accessories and bollards...

Страница 8: ...S A to notify users English EN 5 2 Electrical connections Line voltage 230V 50 60Hz Magnetic sensor photocells max power supply see tab in chap 5 1 Flashing light output voltage 24V 25W Red traffic light and illuminated ring see tab in chap 5 1 Yellow traffic light see tab in chap 5 1 Solenoid valve for the upward movement max voltage 24V AC see tab in chap 5 1 Solenoid valve for the downward move...

Страница 9: ... Endstop opening SMA N C contact Closing button 5 3 Release discharge the system from inside the centre To discharge air from the system and consequently move down the bollards you can open the tap nearby the pressure switch we recommend you to do it when the compressor is shut down in order to avoid that it starts automatically to compensate the pres sure fall To put the system into operation aga...

Страница 10: ...netic loops positioning has influence on the access correct functioning In fact we recommend you to chose first the loops position then the bollards one and then that for the technical centre Position the technical centre in a way to protect it from accidental hurting Provide for a conduit to pass connections through it When necessary you need to install optical and sound signalization to minimize...

Страница 11: ...39 securing screws for inspection flange Flange for inspection on both sides 4 square holes for the M8 locked nuts Conduits connecting area Check that the fastening point is resistant and protected against hurting The fastening should be carried out with suitable screws plugs etc not included depending on the surface typology 1 hook the M8 cage nuts as shown in picture n 1 2 then anchor the reinfo...

Страница 12: ...by using the supplied cables NOTE face the electrical connections d see pict n 2 toward the inside of the technical centre The connecting cables should not come into contact with heated zones i e heating unit compressor head 7 Connection of additional devices 7 Connection of additional devices a Upper cover b Dustproof filter c Carter for motor fastening d Electrical connections including earthing...

Страница 13: ...sate drain optional code COPURA LUX 1 The timed condensate drain must be secured to the compressor support base using the threaded holes provided 2 Disconnect mains power Disconnect the cable between the pressure switch and the motor and insert the timed drain cable 3 Pass the standard drain pipe behind the compressor and cut to size to connect it at the condensate drain inlet 4 Use the remaining ...

Страница 14: ... 6 8 bars The compressor works too frequently Air leak Check the flexible air tube and the couplings if needed use foam spray to detect leaks Air leak at the solenoid valve release Purge the circuit and clean or replace the electrovalve foreign objects in the air circuit The pressure is too high Check that pressure switch 6 8 bar when working Before performing any maintenance procedures cut off th...

Страница 15: ...___________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ________________________________________________________...

Страница 16: ..._____________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ _...

Страница 17: ...e National Law related to the following European Directives and to the applicable parts of the following Standards DIRECTIVES 98 37 CE 98 79 CE MACHINERY DIRECTIVE 2004 108 CE ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 2006 95 CE LOW VOLTAGE DIRECTIVE 87 404 CEE SIMPLE PRESSURE VESSELS DIRECTIVE 97 37 CE PRESSURE EQUIPMENT DIRECTIVE STANDARDS EN 60204 1 EN 1050 EN 60529 EN 60068 2 EN 61000 6 2 EN 610...

Страница 18: ...1 ver 3 3 02 2015 URBACO S A The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO s a to notify users URBACO SA ZA du Couquiou 84320 ENTRAIGUES FRANCE www urbaco com ...

Отзывы: