DEFECTS AND POSSIBLE SOLUTIONS
DEFECT FOUND
POSSIBLE CAUSE
POSSIBLE SOLUTION
The three front LEDs flash
and the buzzer emits 1
beep / minute
The +12 V input voltage is too
low or too high
Check the external power supply or the alarm unit
The buzzer emits 2 beeps
/ minute
Low battery but still can shoot
Replace batteries - See paragraph 14
The buzzer emits 3 beeps
/ minute
Low battery power can not shoot Replace batteries - See paragraph 14
The buzzer emits 10
consecutive beeps every
minute
Batteries absent
Insert batteries
False contact battery case
Move the batteries, turn them
Connector not correct inserted Remove and reinsert the connector
In any case it is useful to use a tester to verify the presence of voltage on the battery case
The machine is armed
(BLUE LED ON)
but does not shoot
The front red LED is on
Has not been made the reset of the cylinders
Reset as described in paragraph 13
The cylinders are empty – Change the cylinders
as described in paragraph 13
The front green LED flashes
The heat exchanger has not yet reached the minimum
temperature of
shooting
, wait for stop flashing
(standard time of heating 60 min)
The machine does not shoot
immediately after arming
For security reasons and to avoid false fog emissions in
power, when the machine is armed, it becomes
operative only after 20". After this time, the emission is
instantaneous.
Wiring error
Verify that the alarm once activated has a tension on
connectors of at least 12V
the buzzer sounds
continuously and the LED
flashes blue
Error reading thermocouples
Disconnect electrical power from the machine for a few
minutes.
If this happens again contact technical support
Not try to repair
Can not arm,
BLUE LED doesn not
become on
Wiring error
Test the terminal that there is a minimum voltage of
between 11V - GND (5) + ARM (3), when the anti-theft
system is activated
When you press the
reset cylinder button can
not hear the sound of the
buzzer, the all front leds
flash but the red LED
does not reset
The Jumper P3 stands in the
"SET" position
CAUTION in this case the shooting time
is reset
Reset cylinders - Paragraph 13
Set shooting time - Paragraph 12
The cylinder does not
enter
The plate is raised
Follow the instructions at paragraph 14
The cylinder does not exit
The cylinder is stuck in the
valvebody
Pressure down and then pull
Setting the shooting time,
the buzzer does not
sound and the LEDs do
not flash
The jumper P3 stands in the
“RESET” position
See the setting mode of the shooting time at paragraph
12