Section 3 – Battery Operation
Charging the Battery
Only use the charger provided in the tool kit to charge the battery for the
ProPEX 200 Battery Expander Tool. Charge the battery before initial operation.
1. Remove the charger from the case.
2. Plug the charger into a standard outlet.
3. Ensure the vent slots in the top and bottom of the charger are
not obstructed.
4. Insert the battery into the charger (+ pole to + pole) with
minimum force.
5. A flashing red light on the battery charger indicates the battery
is charging.
6. Recharge time takes about one hour (the red indicator light on the
charger stops flashing and remains on when the charge is complete).
Note:
Battery temperature increases during and shortly after use. Batteries may
not accept a full charge if they are charged immediately after use. Allow the
battery pack to cool to room temperature before charging.
Caution:
Do not use the charger at ambient temperatures of less than
50°F (10°C) or greater than 104°F (40°C).
Battery Handling
The ProPEX 200 Battery Expander Tool uses rechargeable batteries containing
nickel metal hydride (NiMH) cells. To effectively and properly use the batteries,
keep the following in mind.
• Recharge cool batteries only.
• The battery can recharge 1,000 times, and reaches full capacity after
several charges.
• Store batteries at temperatures greater than 50°F (10°C), but less
than 104°F (40°C), to optimize battery life.
• Only recharge the battery after it is completely drained of power.
• Do not use the charger if dropped or damaged.
• Do not connect two chargers together.
• Keep the battery in a frost-free, dry place.
• Do not allow metal objects (e.g., screws, cutlery, nails) to come in
contact with the battery contacts.
• Use only the provided charger to charge the batteries.
Using any other charger will void the warranty.
• Use only the batteries provided. Using any other battery will
void the warranty.
3