Overview 

The Uponor Heat-only Thermostat (A3100101) is designed 

for precise temperature control of hydronic radiant heating 

applications. The thermostat includes an option to add a floor 

sensor (A9010599) to measure floor temperature for enhanced 

comfort and to protect the surface from overheating.

Additional features

• Operative temperature sensing
• Two-wire power sharing (easier installation)
• Capacitive touchscreen
• Color-enhanced display
• Slim, aesthetic design

Getting started

It is the installer’s responsibility to ensure this thermostat is 

safely installed in accordance with all applicable codes and 

standards. Uponor is not responsible for damages resulting 

from improper installation and/or maintenance.

To avoid personal injury and damage to the 

equipment:

• Read the manuals and documentation to familiarize yourself 

with the product.

• Leave the manuals in an accessible location for the user’s 

reference. (

Note:

 Replacement manuals and documentation 

on this product are available on 

uponorpro.com

.)

• Turn off power to zone boards and other devices prior to 

connecting the thermostat.

• Follow proper installation and operation practices for this 

thermostat. Improper installation or use of the thermostat could 

result in damage to the equipment.

• Do not open the thermostat. There are no serviceable parts 

inside the thermostat and opening it will void the warranty.

This thermostat works effortlessly with other Uponor components. 

However, some commonly used third-party devices (e.g., 

relays, zone valves, etc.) may have compatibility issues with 

this thermostat. If connecting the thermostat to a third-party 

control device, refer to that device’s installation instructions for 

specific information regarding operation with a power-sharing 

thermostat. A 10K Ohm, 0.25 Watt resistor is included in the 

packaging when compatibility issues arise.

Refer to the wiring examples on 

page 7

 for the most 

common wiring applications. For additional information, 

contact Uponor Technical Services at 800.321.4739 (U.S.) 

or 888.994.7726 (Canada).

Tools required

• 

Small, flathead screwdriver

• Phillips screwdriver (mounting hardware)
• Wire stripper and cutter
• 

Volt meter (floor sensor installations)

• Digital thermometer 
• Multimeter

Installation overview

Prior to installing the Uponor thermostat, follow the instructions 
below. (

Note:

 Only experienced and trained professionals familiar 

with low-voltage wiring should attempt to install the thermostat.)

1.  Thoroughly read this manual to understand the proper 

procedures for installation and operation. Failure to do so 
could result in damage to the thermostat or its connected 
equipment, creating a safety hazard. 

2.  Ensure the function and rating of the thermostat is suitable for 

the application. 

3.  Uponor recommends installers use 18 AWG LVT wiring 

for all low-voltage connections (as regulated by local 
building codes).

Placing the thermostat

Where you place the thermostat is extremely important. Install 

the thermostat approximately 5 ft. (1.5m) above the floor on 
a smooth, flat surface. 

Avoid mounting the thermostat in the 

following locations.

• On outside walls
• On interior walls susceptible to solar gains
• On interior walls where the wall is unconditioned
• On a return-air chase
• Near windows
• 

Near fireplaces

• Near stoves, lamps, televisions or other electronics and 

appliances

• In the corner of a room
• In damp areas
• Behind doors
• In areas where the temperature inside the wall differs from the 

room temperature

Installing the thermostat

The thermostat can mount to a wall surface or a standard 
electrical wall box using suitable hardware. The thermostat is 
composed of two parts: the back plate and the controller. Refer 
to the steps below to complete the installation.

1.  Remove the back plate from the thermostat by pulling the 

bottom of the plate away from the controller. The back plate is 
hinged at the top of the controller. 

2.  Locate the back plate on the wall so the connection wires 

are run through the rectangular wiring opening. The wiring 
opening is right next to the wiring terminals.

3.  Align the holes of the back plate with the holes in the electrical 

wall box. Attach the plate with screws. If mounting directly on 
sheetrock, use wall anchors and screws.

Содержание Heat-only Thermostat

Страница 1: ...Uponor Heat only Thermostat with Touchscreen Installation and operation manual...

Страница 2: ...800 321 4739 U S or 888 994 7726 Canada Tools required Small flathead screwdriver Phillips screwdriver mounting hardware Wire stripper and cutter Volt meter floor sensor installations Digital thermom...

Страница 3: ...rete lightweight applications If installing a floor sensor in a lightweight application make sure the sensor is installed within a conduit without splices for easy removal and replacement should the s...

Страница 4: ...y combining the effects of air temperature air speed and thermal radiation This provides superior control of a radiant heating system while maximizing comfort and efficiency The design of the thermost...

Страница 5: ...essed and changed by a qualified installer Improper adjustment of these settings can result in incorrect operation of the heating system Changing the temperature units The thermostat is set to display...

Страница 6: ...sensor operation and the floor sensor fails ERROR will appear on the display The thermostat will ignore any slab setpoint temperature and set the air temperature for 65 F 18 C When the thermostat is s...

Страница 7: ...ES 2 3 4 R1 R2 Y1 Y2 A3100101 Uponor Thermostat with Floor Sensor A3100101 Uponor Thermostat with Floor Sensor A3100101 Uponor Thermostat with Floor Sensor A9010599 Floor Sensor Optional A9010599 Floo...

Страница 8: ...TVG technician for help Setpoint limits settings Minimum range 38 F 3 C to maximum limit setting 50 F 10 C default Maximum range Minimum limit setting to 99 F 37 C 86 F 30 C default Floor sensor 10K...

Отзывы: