Uponor A3800165 Скачать руководство пользователя страница 2

2  |  uponorpro.com

Contents

Overview    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .3

  Safety symbols   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 
  Safety measures  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
 Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
  Technical constraints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 
  Limitations for radio transmission  . . . . . . . . . . . . . . . . . . . . .3 
 Compliance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
  Proper disposal  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Installation   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .4

  System components   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 
  System example   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

  Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5  
  Thermostat operating instructions  . . . . . . . . . . . . . . . . . . . . .5 
  System setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
  Register thermostat and/or system device to a controller. . .7
    Enter registration mode  . . . . . . . . . . . . . . . . . . . . . . . . . . .9
    Exit registration mode   . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
  Unregister one channel  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
  Unregister all channels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
  Actuator autobalancing  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

Technical data   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .10

Foreword

Uponor has prepared this document and all the content  
included solely for information purposes. The contents of this 
document (including graphics, logos, icons, text, and images) 
are copyrighted and protected by worldwide copyright laws  
and treaty provisions. Modification or use of any of the  
contents of the document for any other purpose is a violation  
of Uponor's copyright, trademark and other proprietary rights.
The presumption for the document is all safety measures have 
been fully complied with and, further, that the Climate Control 
Zoning System II, including any components that are part of 
such system, covered by the manual:

• Is selected, planned and installed and put into operation by  

a licensed and trained installer in compliance with current  
(at the time of installation) installation instructions provided by 
Uponor as well as in compliance with all applicable building 
and plumbing codes and other requirements and guidelines;

• Has not been (temporarily or continuously) exposed to 

temperatures, pressure and/or voltages that exceed the  
limits printed on the products or stated in any instructions 
supplied by Uponor;

• Remain in its originally installed condition and is not  

repaired, replaced or interfered with, without prior written 
consent of Uponor;

• Is connected to potable-water supplies or compatible  

plumbing, heating and/or cooling products approved or 
specified by Uponor;

• Is not connected to or used with non-Uponor products,  

parts or components except for those approved or  
specified by Uponor; and

• Does not show evidence of tampering, mishandling, insufficient 

maintenance, improper storage, neglect or accidental damage  
before installation and being put into operation.

While Uponor has made efforts to ensure the document is 
accurate, Uponor does not guarantee or warrant the accuracy 
of the information contained herein. Uponor reserves the right 
to modify the specifications and features described herein, or 
discontinue manufacture of the Climate Control Zoning System 
II described at any time without prior notice or obligation. The 
manual is provided "as is" without warranties of any kind, either 
expressed or implied. The information should be independently 
verified before using it in any manner.

To the fullest extent permissible, Uponor disclaims all 

warranties, expressed or implied, including, but not limited 

to, the implied warranties of merchantability, fitness for 

particular purpose and non-infringement .

This disclaimer applies to, but is not limited to, the accuracy, 
reliability or correctness of the manual.

Under no circumstances shall Uponor be liable for any 

indirect, special, incidental or consequential damages 

or loss that result from the use of or the inability to use 

the materials or information in the manual, or any claim 

attributable to errors, omission or other inaccuracies in  

the manual, even if Uponor has been advised of the 

possibility of such damages .
This disclaimer and any provisions in this document do not 

limit any statutory rights of consumers .

Содержание A3800165

Страница 1: ...Climate Control Zoning System II instruction sheet A3800165 A3801160 A3800167 A3801165...

Страница 2: ...riginally installed condition and is not repaired replaced or interfered with without prior written consent of Uponor Is connected to potable water supplies or compatible plumbing heating and or cooli...

Страница 3: ...s subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired opera...

Страница 4: ...ample Installation System components Part no Description A3800165 Wireless Dial Thermostat T 165 A3800167 Wireless Digital Thermostat T 167 A3801165 Wireless Base Unit 6 zones X 165 A3801160 Wireless...

Страница 5: ...s a reminder for experienced installers Uponor strongly recommends using the full installation and operation manual for complete installation details Pump relay Boiler heat source 24 VAC 24 VAC 15 75...

Страница 6: ...norpro com A3801165 A3801160 A3800167 A3800165 A3800167 A3801165 A3800167 A3801165 A3800167 A3801165 A3801160 1 2 3 1 2 3 4 5 6 7 8 9 10 2 4 V A C 6 0 H z a b 3 s e c o n d s b d c a 24 VAC 1 2 3 4 ON...

Страница 7: ...e controller using the supplied antenna cable 3 Connect the actuators 4 Insert batteries into the thermostats 5 Connect optional external sensor A3800167 only 6 Set the desired DIP switch setting A380...

Страница 8: ...8 uponorpro com 1 3 4 2a 2b 2c 2a 2b A3800167 A3800165 2 3 5 5 s e c o n d s 5 s e c o n d s 3 s e c o n d s 3 s e c o n d s...

Страница 9: ...3 until all available thermostats are registered Exit registration mode 5 Press and hold the OK button on the controller for about 3 seconds until the green LEDs turn off This will end registration mo...

Страница 10: ...2 1 EMC electromagnetic compatibility requirements tests EN 60730 1 and EN 301 489 3 ERM electromagnetic compatibility and radio spectrum matters tests EN 300 220 3 Power supply 24 VAC 10 15 60 Hz VA...

Страница 11: ...Climate Control Zoning System II instruction sheet l 11...

Страница 12: ...124 USA T 800 321 4739 F 952 891 2008 Uponor Ltd 2000 Argentia Rd Plaza 1 Ste 200 Mississauga ON L5N 1W1 CANADA T 888 994 7726 F 800 638 9517 CCZII_InstructionSheet_69569_1216 Copyright 2016 Uponor Pr...

Отзывы: