9
6.Universal DMX controller control
Connection
1. In order to reduce signal errors and avoid signal attenuation and interference during transmission,
a 90-
120Ω (0.25W) resistor can be added between the 2-core and 3-core of the DMX output of
the last machine.,
2.
Connect the fixture with XLR signal cable, one end is connected to the output port of the fixture,
and the other end is connected to the input port of the next fixture. XLR signal lines can only be
used in series, not in parallel. DMX512 signal transmission speed is very fast. Damaged signal wires,
weak soldering, poor contact, etc., will affect signal transmission and cause the system to shut down.
3.
When the machine power supply of a unit is disconnected, the connection of DMX output and
input is bypassed in order to maintain the connection of the DMX line.
4.
Each lamp must have an address code, which can receive the information sent by the console,
and the range is 0-511 (usually 0&1 and 1 are the same).
5.
The terminal of the DMX512 system needs to be equipped with a terminal to reduce errors in
signal transmission.
6.
3-pin XLR connector:3 core XLR: PIN 1: GND, PIN 2: negative signal, PIN 3: positive signal.
Channel settings
Press the ENTER button to enter the menu mode, select the operating mode → select channel
mode,
press the ENTER button to confirm, the current channel mode will flash on the display, use the UP
and
DOWN buttons to select the full mode 24 (CH), press the ENTER button to save. Press the MENU
button to return to the previous menu or wait 30 seconds and automatically exit the menu mode.
Address code setting
When using a general DMX controller to control fixture, you need to set the starting address (1-512)
for the fixture so that the machine can receive DMX signals.
Press the ENTER button to enter the menu mode, select the DMX function, press the ENTER button