CONTENTS

GENERAL  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2

FURNACE CONVERSION   . . . . . . . . . . . . . . . . . . . . . . .  2

TESTS AND ADJUSTMENTS   . . . . . . . . . . . . . . . . . . . .  2

INSTALLATION 
INSTRUCTIONS

CAUTION:

READ ALL SAFETY GUIDES BEFORE  YOU 
BEGIN INSTALLATION.

SAVE THIS MANUAL

NATURAL GAS

HIGH ALTITUDE CONVERSION

ACCESSORY

MODEL 1HA0409

FOR 240 THROUGH 400 MBH 

GAS-FIRED CENTRAL HEATING FURNACES 

WITH 15, 17.5, 20 AND 25 TON 

(MECHANICAL) COOLING

This conversion kit requires installation by a quali-
fied service agency in accordance with the manu-
facturer instructions and all applicable codes and
requirements of the authority having jurisdiction. If
the information in these instructions is not followed
exactly, a fire, explosion, or production of carbon
monoxide may result causing property damage,
personal injury, or loss of life. The qualified agency
performing this work assumes responsibility for the
proper conversion of this appliance with this kit.

For U.S. units, installation must comply with the
National Fuel Gas Code, ANSI Z223.1 - latest edi-
tion, unless superseded by local codes. For Cana-
dian installations, the conversion must comply with
the requirements of the Provincial authorities hav-
ing jurisdiction and in accordance with the CSA
B149.1 installation codes.

WARNING

WARNING

10757-UAI-B-1204

ISO 9001

Certified Quality

Management System

Содержание 1HA0409

Страница 1: ...aving jurisdiction If the information in these instructions is not followed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified agency performing this work assumes responsibility for the proper conversion of this appliance with this kit For U S units installation must comply with the National Fuel Gas Code ANSI ...

Страница 2: ...as were disconnected in Step 2 and 3 or refer to the unit wiring diagram 14 Mark the appropriate data burner orifice size manifold pressure and heat exchanger input capacity on the conversion labels provided and install them adjacent to the unit data plate 15 Refer to the Gas Heat section of the unit installation instructions for proper installation and start up proce dures TESTS AND ADJUSTMENTS A...

Страница 3: ...er orifices where they thread into the manifold Repair any leaks found and recheck DO NOT CHECK WITH OPEN FLAME 11 With main burners off disconnect the manometer and replace the manifold plug Check for gas leaks at this plug 12 Remove jumpers and replace all access panels Manifold pressure for the respective BTU HR input or out put must be adjusted to the IWG as specified on the ori fice label 035...

Страница 4: ...ge without notice Printed in U S A 10757 UAI B 1204 Copyright by Unitary Products Group 2004 All rights reserved Supersedes 10757 UAI A 0602 035 13073 001 A 0602 Unitary 5005 Norman Products York OK Group Drive 73069 ...

Отзывы: