English
BakerTop
™
ChefTop
™
7
The display 1 (STEP) must show number 3.
Attention!
To acces the firmware update mode it is neccesary that all the connected appliances (ovens, holding
cabinets, provers, blast chillers) are switched on but not working.
Ensure the USB memory is in the special connector of the bridge.
Hold the “SELECT” button until the display no. 3 show the net-address where the user needs to update
the firmware. For instance if the user needs to update the blast chiller firmware, at the net-adress no. 5,
it is necessary to press the button “SELECT” until the display no. 3 shows the no. 5.
Slide the firmware in the USB memory with the button “+”. The display no. 3 will show just the
firmware compatible with the appliance selected.
Attention!
Reprogramming the display board firmware the oven looses the user and the adaptive clima programs
memorized. It is necessary to save those kind of programs in the USB memory before the reprogramming.
To start the update, hold the button “M” for 5 seconds: the oven will beep for confirmation. The update
process could last up to 7 minutes.
If the display board firmware has been updated, it is necessary to follow also this procedure before to
use the oven:
• Ensure all the connected appliances (ovens, holding cabinets, provers, blast chilers) are switched on but
not working.
• Push the button “SELEZIONE APPARECCHI” and select the appliance no.1
• Hold at the same time the buttons “+” and “-“ for 5 seconds to enter in the hidden menu.
• Push the button “SELEZIONE APPARECCHI” until on the display 2 appears no. 10.
• Pusch the button SELECT until the display no. 3 shows “LMP”.
• Hold at the same time buttons “STEP” and “START/STOP” for 5 seconds: on the display 4 appear “WAIT”
for at most 30 seconds.
• When the message disappears remove and restore the power to the ovens and the connected appliances.
Firmware update mode