"uart2:" is a DB25 female connector.
"uart3:" is a DB25 male connector.
The mounting holes are connected to chassis ground.
Connector Configuration
Pin
"uart2:"
"uart3:"
Used for:
Remarks
DB25 female
DB25 male
"uart2:"
"uart3:"
1
GNDC
GNDC
RS 232C
RS 232C
Cable shield
2
TXDA
TXDB
RS 232C
RS 232C
Transmitted data from printer
3
RXDA
RXDB
RS 232C
RS 232C
Received data to printer
4
RTSA
RTSB
RS 232C
RS 232C
RTS from printer
5
CTSA
CTSB
RS 232C
RS 232C
CTS to printer
6
DSRA
DSRB
RS 232C
RS 232C
DSR to printer
7
GNDI
GNDI
RS 232 C
RS 232C
Signal ground
8
–
–
–
–
not used
9
–
+20M1
–
Current loop + 20 mA
10
–
–20M1
–
Current loop - 20 mA
11
–
+TXD
–
Current loop TXD +
12
–
–TXD
–
Current loop TXD –
13
–
+20M2
–
Current loop + 20 mA *
14
–
–20M2
–
Current loop – 20 mA *
15
–
–
–
–
not used
16
–
+5VEXT
–
RS 232C/CL
+ 5V max 200 mA. (if strap fitted on P-6)
17
–
–
–
–
not used
18
–
+RXD
–
Current loop RXD +
19
–
–
–
–
not used
20
DTRA
DTRB
RS 232C
RS 232C
DTR permanently high
21
–
–
–
–
not used
22
–
–
–
–
not used
23
–
–
–
–
not used
24
–
–
–
–
not used
25
–
–RXD
–
Current loop RXD –
*/. In case of printer being active receiver.