TIC600 Engineering survey installation
instruction
Zhejiang Uniview Technologies Co., Ltd.
All rights reserved
Document version V1.0 Release date 2020-03-28
Страница 1: ...TIC600 Engineering survey installation instruction Zhejiang Uniview Technologies Co Ltd All rights reserved Document version V1 0 Release date 2020 03 28 ...
Страница 2: ...un direct laser beam or reflection under any circumstances whether the system is turned on or off otherwise it will cause permanent damage to uncooled infrared thermal system This product is a precision electronic instrument so please handle it carefully in the process of use storage and transportation to prevent the equipment from being collided by external force or falling from high place and ot...
Страница 3: ... 3 1 Computer host requirements 6 3 2 Computer network configuration 6 3 3 Temperature measurement software installation and device connection 7 3 4 Software version of equipment 10 3 5 Client software configuration 10 3 6 Visible camera software configuration 14 3 7 Common questions 14 4 Appendix 15 4 1 Equipment components 15 4 2 Equipment assembly instructions 16 4 3 Methods of software install...
Страница 4: ...t and screening system belongs to precision temperature measurement and imaging equipment it has the following requirements for engineering exploration application 2 1 Scenario requirements The ambient temperature should be kept relatively constant to avoid obvious changes in the body surface temperature of the tested personnel When the ambient temperature is within 16 32 the equipment supports ac...
Страница 5: ...ible camera lens needs to be adjusted to the maximum to ensure that it is consistent with the infrared thermal camera s field of view Refer to the Appendix for equipment components and assembly instructions Installation diagram 2 3 Temperature measurement and screening system instructions 2 3 1 Temperature measurement instructions In order to ensure the accuracy of software temperature measurement...
Страница 6: ... the medical temperature measurement instrument If you want to simulate the test of fever personnel you can choose more than 2 normal temperature personnel to test together and one of them can hold a 38 40 warm mineral water bottle and put it on the forehead to test 3 Debugging guidance 3 1 Computer host requirements system win7 or win10 processor i5 9600 and above hard disk 1T above Monitor 17 in...
Страница 7: ...oftware installation and device connection 3 3 1 Software installation 1 First Click Install package Inspection System version V X X X X 2 Second Click Browse button to select software installation path as shown in the figure below ...
Страница 8: ...3 Click Next and Install button to install 4 After installation wait for the system to configure itself then press any key to continue ...
Страница 9: ...y you can see Inspection System software on the desktop Run the software as administrator 3 3 2 Device connection After opening the software with the administrator s permission wait for the device to connect by itself The interface displays the live show which means that the device connection is completed ...
Страница 10: ...ppendix Methods of software installation and upgrade for upgrading The computer client system version needs to be upgraded to V1 0 0 0 or later The version of infrared thermal camera system needs to be upgraded to IR V3 03 20200328 or later The version of visible camera system needs to be upgraded to IPC_Q6301 B0003P22D1907B07 or later 3 5 Client software configuration 3 5 1 Position calibration E...
Страница 11: ...ust be close to the diagonal of the screen 3 If the equipment position does not move after one calibration it is not necessary to calibrate again 3 5 2 Blackbody configuration Enter System para Blackbody configuration interface First select the location of the blackbody and include the whole round target of the blackbody in the blackbody box Then right click the blackbody box to turn on the blackb...
Страница 12: ...ill in the average indoor ambient temperature usually 25 in the Environment Click Apply to complete the setting Attention 1 The ambient temperature compensation function is used to compensate the temperature of the body surface such as forehead according to the ambient temperature so as to avoid inaccurate temperature measurement due to too large difference between the actual ambient temperature a...
Страница 13: ...rm threshold according to the actual needs 37 3 is recommended Confirm that Enable Alarm is selected Click Apply to complete the setting 3 5 5 Alarm record query In the menu bar you can query the alarm record the login password is admin you can see the picture record on the left page ...
Страница 14: ...dify the configuration Change the Server IP to the computer IP address 192 168 1 100 and change the Server Port to 54000 then select the Platform Communication Type as UV V2 3 7 Common questions 3 7 1 There is no image when opening the client software 1 Please check whether the device is powered on whether the power supply is loose and whether the network cable is connected 2 Please check whether ...
Страница 15: ...eck whether the device moves and whether the blackbody temperature source can be seen in the infrared image If not you need to adjust the angle of the device to ensure that the blackbody is seen and then select the blackbody in the software 2 Check whether the external blackbody is powered on It needs to be more than 15 minutes stable after power on 3 Check whether the position calibration is accu...
Страница 16: ...ctions 4 2 1 Equipment installation 1 Open the tripod packing box and take out the tripod and tripod accessories 2 Take off the fixed base of tripod then fix the base on the camera directly finally install the camera to tripod as shown in the figure 3 The installation in blackbody is the same as above ...
Страница 17: ...gure 5 The distance between camera and blackbody is about 2 5M 4 2 2 Line connection 1 Connect the two ends of the output cable to the camera and DC12V power adapter 2 Plug the two ends of the into the output cable and the network port of the computer ...
Страница 18: ...nt related programs are running 2 Open a new client software and run it as an administrator 4 3 2 Visible camera software upgrade 1 Open IE browser log in IP of 192 168 1 13 then log in user name of admin when the password is 123456 switch to Setup System Maintenance point to upgrade package and click upgrade 2 After the upgrade it is recommended to restore the default configuration of visible cam...
Страница 19: ...4 3 3 Infrared thermal camera upgrated ...