10-5/8 HYDRAULIC BACKUP
Model 02F10E
© AUGUST 20, 2013
PAGE 12
9.0 MAINTANCE
9.1 LUBRICATION
Ensuring to lubricate the Backup Unit can greatly extend its life. The following serves as a simple guide
that should be followed on a regular basis:
FIGURE 9.11: GREASING LOCATIONS
RECOMMENDED GREASE GUIDE:
LOC. DESCRIPTION
GREASE
TYPE
APPLICATION
FREQUENCY
1
Jaws & Pins
ESSO
Unirex
EP2
Manually
As required
during job
2
Arm Pins
Grease Gun
(1 - 2 pumps)
Daily during job
3
Hydraulic Cylinder Block
Manually
As required
NOTES:
1) Grease Type is Factory Default and covers operation between -30 to +40 °C (-22 to 104 °F). For
other environments, consult a lubrication specialist.
9.2 HYDRAULICS
After every job the hydraulic fitting and hoses connecting the unit to the Tong as well as in the back of
the Backup should be checked if tight as well as for leaks, wear, and any damage. Components that
have excessive wear or are damaged should be replaced.
Ensure the oil filter used on the hydraulic power unit is kept clean. Dirty hydraulic oil will reduce the life
of the hydraulic cylinder seals.
3
2
2
1
2