64
Information for the installer
MODEL
9k/12k
18k/24k
Tube length with standard load
5 m
5 m
Max. distance between indoor and outdoor unit
25 m
25 m
Additional Gas Charge (Starts at 5m)
15 g/m
25 g/m
Max. level difference between indoor and outdoor
unit
10 m
10 m
Type of gas
R32
R32
Tightening screws
Pipe
Tightening
screw (N x m)
Corresponding
pressure
Tightening bolt
( N x m)
"¼” (ø 6)
15-20
Wrist strength Port Nut
7-9
3/8” (ø 9.52)
31-35
Arm strength
Protective
covers
25-30
"½” (ø 12)
35-45
Arm strength
5/8” (ø 15.88)
75-80
Arm strength
Wiring diagram
For different models, the wiring diagram may be different. Refer to the wiring diagrams
glued to the unit on the inside and outside of the unit, respectively.
In the indoor unit, the wiring diagram is glued under the front panel;
On the outdoor unit, the wiring diagram is glued to the back of the outer handle cover.