OPERATION, TESTING & MAINTENANCE

OPERATION:

 The smoke alarm is operating once the battery is connected. When

products of combustion are sensed, the unit sounds a loud alarm which continues
until the air is cleared.

This alarm incorporates the internationally recognized "temporal tone" horn signal for
evacuation. During alarm mode, the horn produces three short beeps followed by a
two second pause and then repeats.

STANDBY CONDITION:

 The red LED flashes once every 40-60 seconds to indicate

the unit is properly functioning.

LOCAL ALARM CONDITION:

 The red LED flashes rapidly and the unit emits a loud,

pulsating alarm sound.

TESTING:

 Test by pushing the test button on the smoke alarm cover until the alarm

sounds, then release. The alarm sounds if all electronic circuitry, horn and battery are
working. The alarm may continue to sound for up to 10 seconds after the button is
released. If no alarm sounds, the unit may have a defective battery or other failure.
Test the smoke alarm weekly to assure proper operation.

Early warning fire detection is best achieved by the installation of fire detection
equipment in all rooms and areas of the household as follows: A smoke alarm
installed in each separate sleeping area (in the vicinity of, but outside of, the
bedrooms) and heat or smoke alarms in living rooms, dining rooms, kitchens,
hallways, attics, furnace rooms, closets, utility storage rooms, basements and
attached garages. Test the smoke alarm weekly to assure proper operation.

Page 4

NEVER use an open flame of any kind to test this unit. You might accidentally
damage or set fire to the unit or to your home. The built-in test switch accurately
tests the unit's operation as required by Underwriters Laboratories Inc. (UL).

If you choose to use an aerosol smoke product to test the smoke alarm, be
certain to use one that has been Listed to Underwriters Laboratories, Inc. Safety
Standards and use it only as directed. Use of non-UL Listed products or improper
use of UL Listed products may affect the smoke alarm's sensitivity.

MAINTENANCE:

 The smoke alarm is virtually maintenance free. However, under

dusty conditions, a vacuum hose may be used to clear the sensing chamber of dust.

BATTERY REPLACEMENT

The smoke alarm uses a 9 Volt carbon-zinc battery. The battery should last for at
least one year under normal operating conditions. The smoke alarm has a low battery
indicator, an audible "beep." It will operate at 30-40 second intervals for a minimum of
7 days. When this indication occurs, replace the battery with an Alkaline type (Eveready
Energizer #522, Duracell #MN1604), Carbon-Zinc type (Gold Peak #1604P, Eveready
#216).

REPAIRS AND SERVICES

If the smoke alarm is defective in any way, do not tamper with the unit. Return the unit
for servicing. (See warranty for instructions or in-warranty returns.) There will be a
service charge for repairing out of warranty units.

Содержание SS-901-LR

Страница 1: ...continue to insure their lives and properties SMOKE ALARMS CANNOT WORK WITHOUT POWER Battery operated units cannot work if the batteries are missing disconnected or dead if the wrong type of batteries are used or if the batteries are not installed correctly AC only powered units cannot work if the AC power is cut off for any reason If you are concerned about the limitations of battery or AC power ...

Страница 2: ... mounting on an inside partition is preferred to avoid the thermal barrier that may form at the ceiling When mounting smoke alarm on the ceiling locate it a minimum of 4 10cm from a side wall or corner see Diagram A When mounting smoke alarm on a wall if local codes allow use an inside wall with the top edge of the smoke alarm a minimum of 4 10cm and a maximum of 12 30 5cm below the ceiling wall i...

Страница 3: ... and turn the smoke alarm clockwise onto the mounting ring Note Your smoke alarm is equipped with a safety device which prevents mounting unless a battery is installed If your smoke alarm will not lock into the mounting ring check to make sure a battery is installed Page 3 AVOID THESE LOCATIONS the garage products of combustion are present when you start your automobile near appliances or areas wh...

Страница 4: ...allways attics furnace rooms closets utility storage rooms basements and attached garages Test the smoke alarm weekly to assure proper operation Page 4 NEVER use an open flame of any kind to test this unit You might accidentally damage or set fire to the unit or to your home The built in test switch accurately tests the unit s operation as required by Underwriters Laboratories Inc UL If you choose...

Страница 5: ...is all right to do so NATIONAL FIRE PROTECTION ASSOCIATION REQUIRED PROTECTION For your information the National Fire Protection Association s Standard 72 reads as follows 11 5 1 One and Two Family Dwelling Units 11 5 1 1 Smoke Detection Where required by applicable laws codes or standards for the specified occupancy approved single and multiple station smoke alarms shall be installed as follows 1...

Страница 6: ...al Security Instruments Inc at 7 A Gwynns Mills Court Owings Mills Maryland 21117 postage prepaid with a payment of 4 00 to cover the costs of return postage and handling You must include a proof of purchase receipt along with the returned product UNIVERSALDOESNOTWARRANTANDSPECIFICALLYDISCLAIMSANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTA...

Отзывы: