Universal SS-901-LR Скачать руководство пользователя страница 3

FALSE ALARMS

The smoke alarm is designed to minimize false alarms. Smoking will not normally set
off the alarm unless smoke is blown directly into the smoke alarm. Combustion particles
from cooking may set off the alarm if the smoke alarm is located close  to the kitchen
cooking surface. Large quantities of combustion particles are generated from spills or
broiling.

If the smoke alarm does alarm, check for fires first. If a fire is discovered, get out and
call the fire department. If no fire is present, check to see if one of the reasons listed
above may have caused the alarm.

TAMPER LOCKING PIN

To make your smoke alarm somewhat tamper resistant, a locking pin has been
provided. Using this pin will deter children and others from removing the alarm from
the mounting ring. To use the pin, insert it into the hole in the side of the alarm after it
has been installed on the mounting ring. Note that the tamper pin will have to be
removed in order to change the battery, which can be done easily with a pair of long
nose pliers. Using the long nose pliers, pull the pin out of the hole. It is now possible
to remove the smoke alarm from the mounting ring.

INSTALLATION

Your smoke alarm is designed for easy mounting on wall or ceiling. A complete
mounting kit is included with the smoke alarm. First, attach the mounting ring on the
wall or ceiling with the screws provided. Second, push and turn the  smoke alarm
clockwise onto the mounting ring. (Note: Your smoke alarm is equipped with a safety
device which prevents mounting unless a battery is installed. If your smoke alarm will
not lock into the mounting ring, check to make sure a battery is installed.)

Page 3

AVOID THESE LOCATIONS

• the garage – products of combustion are present when you start your automobile.
• near appliances or areas where normal combustion regularly occurs (kitchens, near

furnaces, gas hot water heaters). Use smoke alarms with Silence Control for these
areas.

• in areas with high humidity, like bathrooms or areas near dishwashers or washing

machines. Install at least 3 feet (0.9 meters) away from these areas.

• in areas of turbulent air such as air returns or heating and cooling supply vents,

smoke alarms shall not be located where airflow prevents operation of the alarms.

• in extremely dusty, dirty or insect-infested areas. Loose particles interfere with

smoke alarm operation.

• in areas where temperature may fall below 40

0

F (4.4

0

C) or rise above 100

0

F (37.8

0

C).

• closer than 1 foot (0.3m) from fluorescent lights, electrical "noise" and flickering

may affect the alarm's operation.

• closer than 3 feet (0.9m) horizontal path from the tip of the blade of a ceiling

suspended (paddle) fan.

• on a poorly insulated ceiling or exterior wall (mount smoke alarm on an inside wall).

THIS SMOKE ALARM WILL NOT OPERATE WITHOUT A BATTERY INSTALLED.
PROPER  BATTERY MUST BE INSTALLED IMMEDIATELY WHEN LOW
BATTERY SIGNAL IS GIVEN OR THE UNIT WILL FAIL. TEST WEEKLY. READ
AND FOLLOW ALL INSTRUCTIONS OR UNIT WILL NOT OPERATE PROPERLY.

Содержание SS-901-LR

Страница 1: ...continue to insure their lives and properties SMOKE ALARMS CANNOT WORK WITHOUT POWER Battery operated units cannot work if the batteries are missing disconnected or dead if the wrong type of batteries are used or if the batteries are not installed correctly AC only powered units cannot work if the AC power is cut off for any reason If you are concerned about the limitations of battery or AC power ...

Страница 2: ... mounting on an inside partition is preferred to avoid the thermal barrier that may form at the ceiling When mounting smoke alarm on the ceiling locate it a minimum of 4 10cm from a side wall or corner see Diagram A When mounting smoke alarm on a wall if local codes allow use an inside wall with the top edge of the smoke alarm a minimum of 4 10cm and a maximum of 12 30 5cm below the ceiling wall i...

Страница 3: ... and turn the smoke alarm clockwise onto the mounting ring Note Your smoke alarm is equipped with a safety device which prevents mounting unless a battery is installed If your smoke alarm will not lock into the mounting ring check to make sure a battery is installed Page 3 AVOID THESE LOCATIONS the garage products of combustion are present when you start your automobile near appliances or areas wh...

Страница 4: ...allways attics furnace rooms closets utility storage rooms basements and attached garages Test the smoke alarm weekly to assure proper operation Page 4 NEVER use an open flame of any kind to test this unit You might accidentally damage or set fire to the unit or to your home The built in test switch accurately tests the unit s operation as required by Underwriters Laboratories Inc UL If you choose...

Страница 5: ...is all right to do so NATIONAL FIRE PROTECTION ASSOCIATION REQUIRED PROTECTION For your information the National Fire Protection Association s Standard 72 reads as follows 11 5 1 One and Two Family Dwelling Units 11 5 1 1 Smoke Detection Where required by applicable laws codes or standards for the specified occupancy approved single and multiple station smoke alarms shall be installed as follows 1...

Страница 6: ...al Security Instruments Inc at 7 A Gwynns Mills Court Owings Mills Maryland 21117 postage prepaid with a payment of 4 00 to cover the costs of return postage and handling You must include a proof of purchase receipt along with the returned product UNIVERSALDOESNOTWARRANTANDSPECIFICALLYDISCLAIMSANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTA...