background image

3. After the correct position has been

established, tighten the elbow joint screw
and the sensor head locknut at the end of
the elbow (near the cover).

Screw the lamps into the sockets.

Walk Test

Testing can be performed during daylight.

Testing includes applying electrical power,
walking into the sensing area to determine if
the sensor head is aimed properly and
readjustment of the sensor position, if
necessary. Be sure all controls are set as shown
on Page 3.

1. Turn the wall switch (if installed) to on.

2. Perform the following applicable

procedure(s). Place the circuit breaker to
ON or replace the removed fuse. Observe
that the circuit breaker remains ON (or that
the fuse does not "blow").

3. Walk into the sensing area. The security

floodlight should come on, then go off in
about 5 seconds. If the floodlight does not
come on, refer to 

TROUBLESHOOTING

.

Otherwise, go to Step 4.

4. Walk around the outside of the sensing area

and observe the reaction of the floodlights
as you move into the sensing area.
Determine the protected area. If the
protected area is not satisfactory to you,
redirect the sensor toward the desired
target area.

5. When the sensing area is satisfactory,

tighten the screw and the locknut on the
sensor arm.

Timing Adjustment

The floodlight on-time is variable from 5
seconds to approximately 18 minutes. Set the
on-time as follows:

1. Turn the TIME control clockwise to the

desired setting. The mid-setting is 9 minutes
(approx.). The further it is turned clockwise,
the longer the security floodlight remains
on when triggered.

2. Let the security floodlight turn off. Walk into

the sensor area and observe the time when
the floodlight comes on. Note the time when
the floodlight goes off. Readjust the TIME
control, as necessary, to set the desired
on-time.

Sensitivity (SENS/RANGE)
Adjustment

The sensitivity adjustment was set earlier to
the most sensitive setting. This setting may be
changed to prevent accidental triggering by
family pets or other interference. Turn the
SENS/RANGE control counterclockwise to
make it less sensitive.

NOTE

Your security floodlight is
highly responsive; therefore,
it may occasionally activate
due to rapid environmental
changes.

Test Adjustment

During installation, the DAYLIGHT/TEST-ON
control has been set fully counterclockwise to
let you make adjustments in the daylight. Turn
the DAYLIGHT/TEST-ON control fully clockwise
to prevent operation in daylight. This completes
adjustment.

OPERATION WHERE A WALL
SWITCH IS INSTALLED

If a wall switch is installed, your security
floodlight operates in two modes: automatic and
manual. In automatic mode, the solid-state
circuits are enabled at dusk or dark. When the
infrared sensor detects something in the field,
the security floodlight comes on.

Содержание LITEAIDE HE-100B

Страница 1: ...OWNER S MANUAL PREASSEMBLEDAUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS LiteAide HE 100B HE 100BW HE 112 HE 112W HE 117 HE 117W HE 117 2B ...

Страница 2: ...ogen flood lamps if you are replacing an old floodlight installation save the flood lamps If you are making a new installation obtain two flood lamps from your local hardware store or home center ELECTRICAL POWER CIRCUIT AND WALL SWITCH INSTALLATION If you are not replacing an existing floodlight or another outdoor light at least 8 feet 2 4 meters high or if you do not have a wall switch and would...

Страница 3: ...HT TEST ON control fully counterclockwise Rotate TIME Time Delay control fully counterclockwise 4 Place all wires of the security floodlight through the gasket Locate the gasket against the back side of the cover The security floodlight is ready for outdoor installation Removing an Old Floodlight Assembly if there is one Remove an old floodlight assembly as follows WARNING The old floodlight shoul...

Страница 4: ...loodlight observe the wires white black or green if supplied 5 Remove wire connectors from the old wiring Remove the floodlight 6 Observe the electrical box All standard electrical boxes can be used for installation of the new security floodlight Installation of the Security Floodlight Install the new security floodlight as follows WARNING Ensure that the 110 120 volt 60 Hertz electrical power is ...

Страница 5: ...the sensor above the horizon because it may be damaged from direct sunlight For Wall Eave Mounting 1 Loosen the sensor head locknut and loosen the elbow joint screw 2 Position the sensor horizontally controls facing downward towards the desired target area 4 With the gasket in place against the cover place two mounting screws through the security floodlight cover and through the gasket 5 Tuck wire...

Страница 6: ...s variable from 5 seconds to approximately 18 minutes Set the on time as follows 1 Turn the TIME control clockwise to the desired setting The mid setting is 9 minutes approx The further it is turned clockwise the longer the security floodlight remains on when triggered 2 Let the security floodlight turn off Walk into the sensor area and observe the time when the floodlight comes on Note the time w...

Страница 7: ...s controlled by the solid state circuits in the sensor The security floodlight will only come on in darkness when it detects something in the pattern and it will shut off at the end of the time period NOTE By using the existing circuit breaker the security light can be operated in a manual mode much the same as in the manual mode when a wall switch is installed Set the circuit breaker controlling ...

Страница 8: ...urnpostageandhandling Youmustincludeaproofofpurchase receipt along with the returned product UNIVERSAL DOES NOT WARRANT AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREATED BY STATE LAW SHALL EXTEND BEYOND THE TERM OF THIS WARRANTY UNLESS SUCH LAW OTHERWISE PROVIDE...

Отзывы: