background image

Connect the security floodlight
only to 110-120 volt, 60 Hertz
electrical power. There is
sufficient voltage and current to
harm you if you come into contact
with the 110-120 volt, 60 Hertz
electrical power.

1. Turn off all electrical power to the old

floodlight as follows:

WARNING

Ensure that the 110-120 volt, 60
Hertz electrical power to the old
floodlight is OFF. There is
sufficient voltage and current to
harm you if you come into contact
with the 110-120 volt, 60 Hertz
electrical power.

A. Turn the old floodlight ON.

Observe the floodlight and make
sure the floodlight is lit.

B. At your circuit breaker or fuse

box, set circuit breakers to OFF
or remove fuses until you
observe that the old floodlight is
no longer lit.

C. The safest procedure is to set

the 

MAIN

 circuit breaker or

power switch to OFF. When the
old floodlight is off, proceed to
step 2.

2. Remove flood lamps from old

floodlight.

3. While holding the old floodlight,

remove two screws holding the old
floodlight to an electrical box. Save the
screws for now.

4. While holding the old floodlight,

observe the wires: white, black or
green (if supplied).

5. Remove wire connectors from the old

wiring. Remove the floodlight.

6. Observe the electrical box. All

standard electrical boxes can be used
for installation of the new security
floodlight.

Installation of the Security
Floodlight

Install the new security floodlight as follows:

WARNING

Ensure that the 110-120 volt, 60
Hertz electrical power is OFF.
There is sufficient voltage and
current to harm you if you come
into contact with 110-120 volt, 60
Hertz electrical power.

1. While holding the security floodlight near

the electrical box, twist (clockwise) the
white wire from the electrical cable and the
white wire from the security floodlight
together. Then screw (clockwise) a wire
connector onto the wires. Pull the wire
connector to ensure tightness.

2. Twist (clockwise) the black wire from the

electrical cable and the black wire from the
security floodlight together. Then screw
(clockwise) a wire connector onto the wires.
Pull on the wire connected to ensure
tightness.

3. If green wire is supplied, attach the bare

wire from the electrical cable and the green
wire from the security floodlight together
with a wire connector. Pull on the wire
connector to ensure tightness.

BARE WIRE

WHITE

BLACK

Содержание LITEAIDE HE-100B

Страница 1: ...OWNER S MANUAL PREASSEMBLEDAUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS LiteAide HE 100B HE 100BW HE 112 HE 112W HE 117 HE 117W HE 117 2B ...

Страница 2: ...ogen flood lamps if you are replacing an old floodlight installation save the flood lamps If you are making a new installation obtain two flood lamps from your local hardware store or home center ELECTRICAL POWER CIRCUIT AND WALL SWITCH INSTALLATION If you are not replacing an existing floodlight or another outdoor light at least 8 feet 2 4 meters high or if you do not have a wall switch and would...

Страница 3: ...HT TEST ON control fully counterclockwise Rotate TIME Time Delay control fully counterclockwise 4 Place all wires of the security floodlight through the gasket Locate the gasket against the back side of the cover The security floodlight is ready for outdoor installation Removing an Old Floodlight Assembly if there is one Remove an old floodlight assembly as follows WARNING The old floodlight shoul...

Страница 4: ...loodlight observe the wires white black or green if supplied 5 Remove wire connectors from the old wiring Remove the floodlight 6 Observe the electrical box All standard electrical boxes can be used for installation of the new security floodlight Installation of the Security Floodlight Install the new security floodlight as follows WARNING Ensure that the 110 120 volt 60 Hertz electrical power is ...

Страница 5: ...the sensor above the horizon because it may be damaged from direct sunlight For Wall Eave Mounting 1 Loosen the sensor head locknut and loosen the elbow joint screw 2 Position the sensor horizontally controls facing downward towards the desired target area 4 With the gasket in place against the cover place two mounting screws through the security floodlight cover and through the gasket 5 Tuck wire...

Страница 6: ...s variable from 5 seconds to approximately 18 minutes Set the on time as follows 1 Turn the TIME control clockwise to the desired setting The mid setting is 9 minutes approx The further it is turned clockwise the longer the security floodlight remains on when triggered 2 Let the security floodlight turn off Walk into the sensor area and observe the time when the floodlight comes on Note the time w...

Страница 7: ...s controlled by the solid state circuits in the sensor The security floodlight will only come on in darkness when it detects something in the pattern and it will shut off at the end of the time period NOTE By using the existing circuit breaker the security light can be operated in a manual mode much the same as in the manual mode when a wall switch is installed Set the circuit breaker controlling ...

Страница 8: ...urnpostageandhandling Youmustincludeaproofofpurchase receipt along with the returned product UNIVERSAL DOES NOT WARRANT AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREATED BY STATE LAW SHALL EXTEND BEYOND THE TERM OF THIS WARRANTY UNLESS SUCH LAW OTHERWISE PROVIDE...

Отзывы: