background image

Universal

 

Walk-In Bathtubs

 

5701 NW 35 Avenue Miami, FL 33142 PHONE: 877-360-4454 FAX: 866-560-1060 www.universaltubs.com

Page 11

OPERATING INSTRUCTIONS

OPERA

TING

  INSTRUCTIONS

Universal

 

Walk-In Bathtubs

 

5701 NW 35 Avenue Miami, FL 33142 PHONE: 877-360-4454 FAX: 866-560-1060 www.universaltubs.com

Page 10

OPERATING INSTRUCTIONS

OPERA
TING

  INSTRUCTIONS

Universal

 

Tubs

tm

Universal

 

Tubs

tm

DraIn connectIon

To ensure safe transit for your walk-in tub, the overflow drain components are 

not connected to the unit during the process of production. The following in-

structions are provided for installation purposes: Your walk-in tub is supplied 

with a 1 ½” drain pipe overflow. The open and close valve with the turn knob 

should be attached to the unit at the 1 ½” pre-drilled opening in the wall of the 

unit from the outside. The opposite end of the overflow should be attached to 

the 1 ½” pre-drilled opening in the foot well of the unit from the underside. The 

chrome turn knob and the drain cover should be attached to the appropriate ends

of the overflow drain from the inside of the unit. Place the chrome cap with stem into 

the floor drain to close off the opening. The cable attached to the turn knob of the overflow is also connected to a lever inside the floor drain 

which allows the drain to be opened or closed. Once the components of the overflow are secured into place, turn the overflow knob to the 

open and closed position to ensure proper function. The cap and stem will move up and down, opening and closing the drain  (

Figure 1

).

Your walk-in tub also has a door drain to remove excess water from the door after 

each use. From the underside of the unit, a hose is connected to the door drain with 

a check valve. This hose and valve is to provide a one-way flow from the door drain 

to the main drain pipe. The check valve will constrict the water flow away from the 

door. Insert the opposite end of the hose into the port on the main drain. Be sure the 

port is open before attaching the hose. Secure the hose with clamps or ties. Once 

the hose is in place, close the door on the unit, place the handle in the locked posi-

tion, and fill tub with at least 12” of water to test the connection. Once the completion 

of the drain components are installed and have been tested for proper function, the unit can be leveled and give a final water test 

before installation of unit (

Figure 2

).

1 1/2” Door Drain Pipe supplied 

7 1/2”

FIgure 1

Floor Drain

Incorrect

Flow

Door Drain

Correct

Check Valve

Flo

w

FIgure 2

connectIng tHe autoDraIn

HIgH-speeD autoDraIn For soaKIng tuB anD/or aIr sYsteM

• 

Drain System requires the connection to a minimum 1 ½ sanitary drain line.

• 

Use UPC Approved PvC Glue, primer, and Schedule 40 1 ½ ’ pipe.

• 

Do not change or modify the location and or piping of the Back Flow Preventer.

• 

The sanitary tee is installed directly above the drain tee with clearance not greater than 1’’.

• 

Dry fit the drain overflow assembly to the sanitary drainage pipe and check for proper fit.

• 

Glue the High-Speed Autodrain Fittings, pipe and drain overflow assembly to the sanitary drainage pipe.

note: Water tIgHt InstallatIon oF tHe Waste/ overFloW Is tHe Installer’s responsIBIlItY. DraIn leaKage Is 

excluDeD FroM tHe unIversal tuBs WarrantY oF tHIs proDuct.

note: We Have taKen responsIBle precautIons to ensure tHe HIgH-speeD autoDraIn Is suItaBle For 

resIDentIal pluMBIng. It Is responsIBIlItY oF tHe Installer to Insure tHe sanItarY sYsteM Is acceptaBle 

For tHe use oF tHe HIgH-speeD autoDraIn. We Do not accept responsIBIlItY For DaMage arIsIng FroM tHe 

use oF tHe HIgH- speeD autoDraIn.*

*-Ensure compliance with local plumbing codes.

110Vt-60hz pump (15 Amp Circuit)

overflow

drain cable

drain cable

drain 

drain shoe 

sanitary tee

drain tee

90° Elbow

reducer 1 1/2-1”

air button (on/off)

back flow preventer

air button (on/off)

diverter valve

jets

overflow

drain cable

drain cable

drain 

drain shoe 

sanitary tee

drain tee

90° Elbow

reducer 1 1/2-1”

back flow preventer

110Vt-60hz pump (15 Amp Circuit)

soaKer & aIr autoDraIn connectIon

HYDro & Dual autoDraIn connectIon

Содержание 2646

Страница 1: ...X 866 560 1060 www universaltubs com Universal Tubs tm Installation operating instructions Installation OPERATING INSTRUCTIONS 2646 Universal WALK IN BATHTUBS 5701 NW 35 Avenue Miami FL 33142 Phone 877 360 4454 Fax 866 560 1060 info universaltubs com http www universaltubs com MODEL ...

Страница 2: ...gistration 3 Savethismanual 4 UNPACKINGTHEUNIT 5 PRE INSTALLATION 6 INSTALLATIONPREPARATION 7 ElectricalPREPARATION 8 INSTALLATIONPROCEDURES 9 DRAINCONNECTION 10 ConnectingtheAutodrain 11 Installationandextensionpanels 12 Faucetinstallation 13 operatingsafetyinstructions 14 operatinginstructions 16 tubcontrols 18 CLEANINGANDMAINTENANCE 19 warranty 20 RETURNPOLICY 22 productregistrationcard 23 Tabl...

Страница 3: ...NW 35 Avenue Miami FL 33142 Phone 877 360 4454 Fax 866 560 1060 info universaltubs com http www universaltubs com Thank you contact Product registration Product registration ProductRegistration ToensurethatyourwarrantyisregisteredwithUniversalWalk InBathtubs complete signandreturnthisregistrationcardwithin30daysofthepurchase NOTE Yourwarrantywillnotberecognized by UniversalWalk In Bathtubs unless ...

Страница 4: ...AND ELECTRICIANS SHOULD BE EMPLOYED TO INSURE PROPER INSTALLATION INSTALLERS ASSUME ALL LIABILITY FOR THE CORRECT INSTALLATION PROCEDURES ONLY ACCESSORIES AUTHORIZED BY THE MANUFACTURER SHOULDBEUSEDWITHTHISPRODUCT IMPORTANTSAFETYINSTRUCTIONS Warning When USING THIS PRODUCT BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED ReadANDFOLLOWALLINSTRUCTIONSPERTAININGTORISKOFFIRE ELECTRICALSHOCK AND OROTHERINJU...

Страница 5: ...utesandinspectforleaks Inspecttheunionsaroundthepump ifleaks persist from theunionsaftertightening loosentheunionsandinsuretheO ringisseatedproperly NOTE Ifthepumpsdonotoperate checkthebreakertoensurepowerisonandthecableconnectingthe controls to the pumpisattached WARNING DO NOT RUN ANY PUMPS UNLESS THE TUB IS FILLED WITH WATER TO PROPER LEVEL DAMAGEDUETODRYRUNNINGPUMPSISNOTCOVEREDUNDERWARRANTY Fa...

Страница 6: ...p GFCI Soaker w Auto Drain w Light 15 Amp GFCI Jet Massage Or Air Massage 15 Amp GFCI Jet Massage Or Air Massage w Light 15 Amp GFCI Jet Massage Or Air Massage w Auto Drain 15 Amp GFCI Jet Massage Or Air Massage w Light Auto Drain 15 Amp GFCI Jet Massage Air Massage Dual 20 Amp GFCI Jet Massage Air Massage Dual w Light 20 Amp GFCI Jet Massage Air Massage Dual w Auto Drain 20 Amp GFCI Jet Massage A...

Страница 7: ...otheportonthemaindrain Besurethe port is open before attaching the hose Secure the hose with clamps or ties Once the hose is in place close the door on the unit place the handle in the locked posi tion andfilltubwithatleast12 ofwatertotesttheconnection Oncethecompletion of the drain components are installed and have been tested for proper function the unit can be leveled and give a final water tes...

Страница 8: ...Operating instructions Universal Tubs tm Universal Tubs tm assembly placement Faucetinstallation fixing nut fixing nut fixing nut hot control handle cold control handle spout shower head diverter rubber washer fiber washer valve body gasket steel braded 19 hose steel braded 19 hose 72 shower hose local water line hot water cold water MOLDED FLANGE TO BOLT UNIT TO WALL CUSTOM BUILT WALL SECTION S F...

Страница 9: ...ppliances such as a hair dryer lamp telephone radio or television within four feet of thisbathtub Never drop or insertanyobjectsintoanyopenings Do not operatethisunitwithouttheguardoverthesuctionfittings WARNING Riskofhyperthermiaandpossibledrowning Peopleusingmedications herbalremedies sleepaids and orhaving adversemedicalhistoryshouldconsultaphysicianbeforeusingthisproduct WARNING Nofoodoralcoho...

Страница 10: ...ontrol button which starts the air flow see page18 Adjustthedirectionandrateofflowofthejetsbymovingthenozzlefordirection Turneithertheoutsideringorthenozzleclockwise orcounterclockwiseforflow somejetsadjusttheflowwiththeoutsideringandsomewiththenozzle Adjusttheairpressureflow ofallwater jetsbyusingtheairvolumecontrol seepage18 whichcontrolsair watermixture Universalwalk intubsequippedwiththechromo...

Страница 11: ...romacanister AROMA CANISTER Placed inside the aroma container Check frequently and replaceasneeded 1 2 3 4 6 5 Controlsdepictedmayvaryfromthosefoundonyourunit Varianceisbasedonthe optionspurchasedduringtheorderprocess CLEANING AND MAINTENANCE Pumpandpipecirculationsystemsshouldbeflushedbeforefirstuseandonamonthlybasis when product is undernormal use Belowaretherecommendedproceduresforcleaning Do n...

Страница 12: ...r contractor Failure to do so will hereby void the warranty There will be a charge for replacement parts or the replacement of the entire electrical unit if the defective unit is returned for any of the reasons listed above NOTE within the limited one year warranty there will be a prorated charge for any electrical and plated replacementsparts includingshippingandhandlingcharges Manufacturer reser...

Страница 13: ...mustbeinitsoriginal packaging and receivedatUniversalWalk InBathtubs insaleablecondition Allreturnswillreceivea15 restockingfeeplusall freight costs of theoriginalshipmentandreturnshipmenttoUniversalWalk InBathtubs Allrequestsfor returnmustfirstbeapprovedbyUniversalWalk InBathtubs andhaveanassignedReturnedMerchandise Authorization number RMA return policy return policy Universal Walk In Bathtubs P...

Страница 14: ...lk In Bathtubs 5701 NW 35 Avenue Miami FL 33142 PHONE 877 360 4454 FAX 866 560 1060 www universaltubs com Universal Tubs tm installation OPERATING INSTRUCTIONS installation operating instructions Universal Tubs tm ...

Отзывы: