tuB controls

aroMa canIster

exaMple tuB controls*

1

2

3

4

5

6

HYDro control (puMp)

Used to turn the water jets 

on

 and 

oFF

.

aIr control (BloWer)

Used to control the air jets on the system.

1st press:

 Blower starts at 

Max

 speed

2nd press: 

Blower at 

MeD

 speed

3rd press: 

Blower at 

MIn

 speed

4th press:

 Blower turns 

oFF

cHroMo control (lIgHt)

Used to turn the chromotherapy lights 

on

 and 

oFF

.

Pressing the button repeatedly will cycle through different 
color modes.

aIr pressure control

Used to increase or decrease air pressure flowing through the 
water jets.

aroMa contaIner

Unscrew to place or replace the aroma canister.

aroMa canIster

Placed inside the aroma container. Check frequently and 

replace as needed.

1

2

3

4

6

5

*

Controls depicted may vary from those found on your unit. variance is based on the 

options purchased during the order process.

cleanIng anD MaIntenance

Pump and pipe circulation systems should be flushed before first use and on a monthly basis when product is under normal use. 

Below are the recommended procedures for cleaning:

• 

Do not run whirlpool dry. Fill the tub with hot water 2-3 inches above the jets and add 2-3 teaspoons of low foaming 

detergent such as dishwashing machine detergent

• 

Turn on whirlpool system and run for 10 minutes

• 

Drain tub completely

• 

Fill tub with cold water above jets

• 

Turn on whirlpool system and run for 15 minutes

• 

Drain tub completely

• 

Cleaning the suction cover: Clean and remove any hair or lint from the suction cover (see image below). On a monthly basis, 

unscrew the suction cover and clean away any hair, lint or debris from the cover and housing, then remount the cover in place. Some 

suctions are not designed to be removed; only suctions that have screws on the cover, visible from the inside of the tub, can be 

removed.

WarnIng!

 

never operate tHe unIt WItH tHe saFetY suctIon cover oFF.

suctIon cover

Содержание 2646

Страница 1: ...X 866 560 1060 www universaltubs com Universal Tubs tm Installation operating instructions Installation OPERATING INSTRUCTIONS 2646 Universal WALK IN BATHTUBS 5701 NW 35 Avenue Miami FL 33142 Phone 877 360 4454 Fax 866 560 1060 info universaltubs com http www universaltubs com MODEL ...

Страница 2: ...gistration 3 Savethismanual 4 UNPACKINGTHEUNIT 5 PRE INSTALLATION 6 INSTALLATIONPREPARATION 7 ElectricalPREPARATION 8 INSTALLATIONPROCEDURES 9 DRAINCONNECTION 10 ConnectingtheAutodrain 11 Installationandextensionpanels 12 Faucetinstallation 13 operatingsafetyinstructions 14 operatinginstructions 16 tubcontrols 18 CLEANINGANDMAINTENANCE 19 warranty 20 RETURNPOLICY 22 productregistrationcard 23 Tabl...

Страница 3: ...NW 35 Avenue Miami FL 33142 Phone 877 360 4454 Fax 866 560 1060 info universaltubs com http www universaltubs com Thank you contact Product registration Product registration ProductRegistration ToensurethatyourwarrantyisregisteredwithUniversalWalk InBathtubs complete signandreturnthisregistrationcardwithin30daysofthepurchase NOTE Yourwarrantywillnotberecognized by UniversalWalk In Bathtubs unless ...

Страница 4: ...AND ELECTRICIANS SHOULD BE EMPLOYED TO INSURE PROPER INSTALLATION INSTALLERS ASSUME ALL LIABILITY FOR THE CORRECT INSTALLATION PROCEDURES ONLY ACCESSORIES AUTHORIZED BY THE MANUFACTURER SHOULDBEUSEDWITHTHISPRODUCT IMPORTANTSAFETYINSTRUCTIONS Warning When USING THIS PRODUCT BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED ReadANDFOLLOWALLINSTRUCTIONSPERTAININGTORISKOFFIRE ELECTRICALSHOCK AND OROTHERINJU...

Страница 5: ...utesandinspectforleaks Inspecttheunionsaroundthepump ifleaks persist from theunionsaftertightening loosentheunionsandinsuretheO ringisseatedproperly NOTE Ifthepumpsdonotoperate checkthebreakertoensurepowerisonandthecableconnectingthe controls to the pumpisattached WARNING DO NOT RUN ANY PUMPS UNLESS THE TUB IS FILLED WITH WATER TO PROPER LEVEL DAMAGEDUETODRYRUNNINGPUMPSISNOTCOVEREDUNDERWARRANTY Fa...

Страница 6: ...p GFCI Soaker w Auto Drain w Light 15 Amp GFCI Jet Massage Or Air Massage 15 Amp GFCI Jet Massage Or Air Massage w Light 15 Amp GFCI Jet Massage Or Air Massage w Auto Drain 15 Amp GFCI Jet Massage Or Air Massage w Light Auto Drain 15 Amp GFCI Jet Massage Air Massage Dual 20 Amp GFCI Jet Massage Air Massage Dual w Light 20 Amp GFCI Jet Massage Air Massage Dual w Auto Drain 20 Amp GFCI Jet Massage A...

Страница 7: ...otheportonthemaindrain Besurethe port is open before attaching the hose Secure the hose with clamps or ties Once the hose is in place close the door on the unit place the handle in the locked posi tion andfilltubwithatleast12 ofwatertotesttheconnection Oncethecompletion of the drain components are installed and have been tested for proper function the unit can be leveled and give a final water tes...

Страница 8: ...Operating instructions Universal Tubs tm Universal Tubs tm assembly placement Faucetinstallation fixing nut fixing nut fixing nut hot control handle cold control handle spout shower head diverter rubber washer fiber washer valve body gasket steel braded 19 hose steel braded 19 hose 72 shower hose local water line hot water cold water MOLDED FLANGE TO BOLT UNIT TO WALL CUSTOM BUILT WALL SECTION S F...

Страница 9: ...ppliances such as a hair dryer lamp telephone radio or television within four feet of thisbathtub Never drop or insertanyobjectsintoanyopenings Do not operatethisunitwithouttheguardoverthesuctionfittings WARNING Riskofhyperthermiaandpossibledrowning Peopleusingmedications herbalremedies sleepaids and orhaving adversemedicalhistoryshouldconsultaphysicianbeforeusingthisproduct WARNING Nofoodoralcoho...

Страница 10: ...ontrol button which starts the air flow see page18 Adjustthedirectionandrateofflowofthejetsbymovingthenozzlefordirection Turneithertheoutsideringorthenozzleclockwise orcounterclockwiseforflow somejetsadjusttheflowwiththeoutsideringandsomewiththenozzle Adjusttheairpressureflow ofallwater jetsbyusingtheairvolumecontrol seepage18 whichcontrolsair watermixture Universalwalk intubsequippedwiththechromo...

Страница 11: ...romacanister AROMA CANISTER Placed inside the aroma container Check frequently and replaceasneeded 1 2 3 4 6 5 Controlsdepictedmayvaryfromthosefoundonyourunit Varianceisbasedonthe optionspurchasedduringtheorderprocess CLEANING AND MAINTENANCE Pumpandpipecirculationsystemsshouldbeflushedbeforefirstuseandonamonthlybasis when product is undernormal use Belowaretherecommendedproceduresforcleaning Do n...

Страница 12: ...r contractor Failure to do so will hereby void the warranty There will be a charge for replacement parts or the replacement of the entire electrical unit if the defective unit is returned for any of the reasons listed above NOTE within the limited one year warranty there will be a prorated charge for any electrical and plated replacementsparts includingshippingandhandlingcharges Manufacturer reser...

Страница 13: ...mustbeinitsoriginal packaging and receivedatUniversalWalk InBathtubs insaleablecondition Allreturnswillreceivea15 restockingfeeplusall freight costs of theoriginalshipmentandreturnshipmenttoUniversalWalk InBathtubs Allrequestsfor returnmustfirstbeapprovedbyUniversalWalk InBathtubs andhaveanassignedReturnedMerchandise Authorization number RMA return policy return policy Universal Walk In Bathtubs P...

Страница 14: ...lk In Bathtubs 5701 NW 35 Avenue Miami FL 33142 PHONE 877 360 4454 FAX 866 560 1060 www universaltubs com Universal Tubs tm installation OPERATING INSTRUCTIONS installation operating instructions Universal Tubs tm ...

Отзывы: