WWW.UNIVERSALTOOLUSA.COM
Please contact 1-800-356-3392 for further assistance.
Warranty
Limited Warranty: Universal Tool warrants its tools to be free from defects in material and workmanship for one year from the date of
purchase. This warranty does not apply to tools which have been abused, misused, modified or repaired by someone other than Universal
Tool or its authorized service centers. If a UT tool proves defective in material or workmanship within one year after purchase, return
it to any authorized service center or Universal Tool freight prepaid. Please enclose your name, address and adequate proof of date of
purchase and a short description of the defect. Universal Tool will,at its option, repair or replace defective tools free of charge. Repairs or
replacements are warranted as described above for the remainder of the original warranty period. Universal Tool's sole liability and your
exclusive remedy under this warranty is limited to repair or replacement of the defective tool.
There are no other warranties expressed or implied and Universal Tool shall not be liable for incidental, consequential or special damages,
or any other damages,costs or expenses excepting only the cost or expense of repair or replacement as described above.
Troubleshooting
Problem
Possible Cause
Solution
The tool runs slowly or will not
operate.
There is grit or gum in the tool.
Flush the tool with air tool oil or gum solvent.
The tool is out of oil.
Lubricate the tool according to the lubrication
instructions in this manual.
The air pressure is low.
□
Adjust the regulator on the tool to the
maximum setting.
□
Adjust the compressor regulator to the tool’s
maximum setting of 90 psi.
The air hose leaks.
Tighten and seal the hose fittings with pipe thread
tape if leaks are found.
The air pressure drops.
□
Ensure the hose is the proper size. Long
hoses or tools using large volumes of air may
require a hose with an I.D. of ½" or larger
depending on the total length of the hose.
□
Do not use a multiple number of hoses
connected together with a quick connect
fitting. This causes additional pressure drops
and reduces the tool power. Directly connect
the hoses together.
There is a worn rotor blade in the motor.
Replace the rotor blade.
There is a worn ball bearing in the motor.
Remove and inspect the bearing for rust, dirt, and
grit. Replace or clean and grease the bearing with
bearing grease.
There is moisture blowing out
of the tool’s exhaust.
There is water in the tank.
Drain the tank. (See the air compressor manual
for instructions.) Lubricate the tool and run it until
water is not evident. Lubricate the tool again and
run for 1-2 seconds.
The tool impacts slowly or not
at all.
The tool needs lubricating.
Lubricate the air motor and the impact mechanism
according to the lubrication instructions in this
manual.
The tool regulator setting is in the wrong position.
Adjust the regulator on the tool to the maximum
setting.
The tool impacts rapidly, but
will not remove bolts.
The tool has a worn impact mechanism.
Replace the worn impact mechanism components.
The tool does not impact.
The impact mechanism is broken.
Replace the broken impact mechanism
components.