background image

®U.S. Registered Trademark
Copyright © 1997 Honeywell Inc.  •   All Rights Reserved

X-XX UL

INSTALLATION INSTRUCTIONS

208414, 208415 Replacement Power Supply

Kit for Electronic Air Cleaner

APPLICATION

These kits replace the power supplies with W8600E solid-
state performance indicators (SSPI) used in the F50F and
F58F  Electronic Air Cleaners. See Table 1.

NOTE:

The W8600E Remote Performance Indicator
driver circuit board has been calibrated with the
power supply in this kit. False wash indications
will occur if used with a different power supply.

69-1136-1

Table 1. Power Supply Replacement Guide.

NOTE:

Use the 120 Vac replacement power supply
indicated in Table 1 when servicing the F50F or
F58F electronic air cleaners which have been
modified with the 203365A transformer kit to
operate at 220/240 Vac.

INSTALLATION

When Installing this Product…

1. Read these instructions carefully. Failure to follow

them could damage the product or cause a hazard-
ous condition such as electrical shock.

2. Check the ratings given in the instructions and on

the product to make sure the product is suitable for
your application.

3. Installer must be a trained, experienced service

technician.

4. After installation is complete, check out product

operation as provided in these instructions.

WARNING

ELECTRIC SHOCK HAZARD. SAFETY HAZARD.
CAN CAUSE ELECTRICAL SHOCK OR
EQUIPMENT DAMAGE
Disconnect power before removing old power
supply board and installing replacement power
supply board.

To Remove Old Power Supply Board

NOTE:

It is advisable to observe the location of
leadwires to be replaced on the power supply.
Tag the leadwires as they are removed to help
you correctly reconnect them.

Open access door. See Fig. 1.

Open power box.

Nominal Size

Ionizer Current  

Replacement Power Supply  

(in.)

(mm)

(mA)

(OS No.)

F50F

120 Vac, 60 Hz

16 x 20

406 x 508

1.33

208414G

16 x 25

406 x 635

1.65

208414B

20 x 20

508 x 508

1.65

208414B

20 x 25

508 x 635

2.10

208414A

20 x 12-1/2

508 x 318

1.05

208414C

220/240 Vac,
50/60 Hz  

20 x 12-1/2

508 x 318

1.05

208415C

F58F

120 Vac, 60 Hz

20 x 25

508 x 635

2.10

208414A

Содержание 208414

Страница 1: ...se a hazard ous condition such as electrical shock 2 Check the ratings given in the instructions and on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After installation is complete check out product operation as provided in these instructions WARNING ELECTRIC SHOCK HAZARD SAFETY HAZARD CAN CAUSE ELECTRICAL SHOCK...

Страница 2: ...t of the installation check the wall panel and make sure the ON LED is lit The W8600E CHECK LED will come on if there is a problem with the high voltage power supply 2 Turn off the system blower The neon light should go off after a few seconds The neon light shows that the air cleaner is energized and the high voltage power supply is working properly 3 Turn on the system blower With the air cleane...

Страница 3: ... BOARD ORANGE GRAY VIOLET BLACK 1 INTERLOCK SWITCH 2 OUTPUT REDUCTION JUMPER 3 AIRFLOW SWITCH DISABLE JUMPER 4 RESISTOR FOR W8600 WASH INDICATION THRESHOLD PRESENT ON POWER SUPPLIES MANUFACTURED WITH DATE CODE 9430 AND EARLIER 5 ONE CELL UNIT SIMILAR BUT WITH JUST ONE CELL 6 P1 P2 TERMINALS ON 120V MODELS ONLY POWER CONNECTIONS ON 240V MODELS ARE TO QUICK CONNECTS ON POWER SUPPLY TRANSFORMER BROWN...

Страница 4: ... INTERLOCK SWITCH 2 SHORTING BAR 3 AIRFLOW SWITCH DISABLE JUMPER 4 W8600E REMOTE PERFORMANCE INDICIATOR DRIVER 5 TOP TERMINAL ON TRANSFORMER 6 INPUT POWER PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED 7 NEON LIGHT M15098 2 7 BLACK RED TEST BUTTON CONTACT BOARD RED IONIZER BLACK COLLECTOR BLACK 4 BLACK BLACK BROWN BLACK BLACK WHITE GREEN 3 6 1 5 E5 E6 J5 J1 J1 J2 GREEN YELLOW RED BLU...

Страница 5: ...OPERATION CAN BE CHECKED SEPARATELY SEE W8600E INSTRUCTIONS 2 3 M5609E FOLLOW THE STEPS IN ORDER DO NOT SKIP AROUND EACH TIME YOU ISOLATE AND FIX A PROBLEM GO BACK TO START REPEAT ALL THE STEPS UNTIL THE AIR CLEANER CHECKS OUT OK 1 2 3 1 THIS STEP EXPOSES DANGEROUSLY HIGH VOLTAGE ONLY A QUALIFIED SERVICE TECHNICIAN SHOULD ATTEMPT THIS STEP WARNING CHECK NEON LIGHT TURN OFF AIR CLEANER AND REMOVE C...

Страница 6: ... ozone generated by the air cleaner can be reduced in one of two ways 1 Install an activated carbon filter downstream from the air cleaner Make sure particles from the air filter cannot fall into the air cleaner WARNING ELECTRIC SHOCK HAZARD CAN CAUSE PERSONAL INJURY Only a trained service technician should perform the following procedure 2 This will reduce ozone production about 20 to 25 percent ...

Страница 7: ...l not apply if it is shown by Honeywell that the defect or malfunction was caused by damage that occurred while the product was in the possession of a consumer Honeywell sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR I...

Страница 8: ...TRONIC AIR CLEANER Home and Building Control Honeywell Limited Honeywell Limitée 155 Gordon Baker Road North York Ontario M2H 3N7 69 1136 1 J H Rev 11 97 Home and Building Control Honeywell Inc Honeywell Plaza P O Box 524 Minneapolis MN 55408 0524 Printed in Mexico ...

Отзывы: