If you choose to use an aerosol smoke product to test the smoke alarm, be certain to use 
one that has been Listed to Underwriters Laboratories, Inc. Safety Standards and use it 
only as directed. Use of non-UL Listed products or improper use of UL Listed products may 
affect the smoke alarm's sensitivity.
NUISANCE ALARM SILENCE FEATURE: 

This feature is to be used only when a known alarm 

condition,  such  as  smoke  from  cooking,  activates  the  smoke  alarm. The  smoke  alarm  Silence 
Feature is activated by pushing and releasing the Test/Silence button on the smoke alarm cover 
while in alarm condition. The smoke alarm will automatically reduce sensitivity and the red LED 
will blink on approx. every 10 seconds to indicate the alarm is in the Silence mode. The smoke 
alarm will gradually regain normal sensitivity and sound the alarm if particles of combustion are still 
present. The approx. 10 minute Silence feature may be used repeatedly until the air has cleared, by 
pushing and releasing the Test/Silence button again. Resetting the smoke alarm after a nuisance 
alarm is recommended.
NOTE: If the Test/Silence button is pressed and held during the Silence mode, the smoke alarm will 
be tested normally. Upon the release of the Test/Silence button, the Silence mode will be restarted.

Before using the alarm Silence Feature, identify the source of smoke and be certain that 
safe conditions exist.
REGULAR MAINTENANCE: 

Test the alarm at least once per week to verify it is operating properly. 

Clean this alarm at least once a month to remove dust, dirt, insects and debris. Using a soft brush 
or wand attachment to a vacuum cleaner, vacuum all sides and cover of smoke alarm. Be sure all 
the vents are free of debris.
DO NOT use spray cleaning chemicals or insect sprays directly on or near the alarm. DO NOT paint 
the alarm. Doing so may permanently damage the alarm and interfere with alarm’s ability to sense 
smoke. The outside can be wiped with a damp cloth. DO NOT use any household cleaning agents, 
solvents or sprays including compressed gas dusters or any other chemical on or near your alarm. 
DO NOT disassemble or attempt to clean inside the alarm. This alarm contains no serviceable parts.
If the alarm becomes contaminated by excessive dirt or grease, and cannot be cleaned, it should 
be replaced immediately. Alarms have a limited life and should always be replaced 10 years from 
the date of purchase.

AFTER CLEANING, REINSTALL YOUR ALARM AND 

TEST YOUR ALARM BY USING THE TEST BUTTON

NEVER use an open flame of any kind to test this smoke alarm. You might accidentally 
damage or set fire to the smoke alarm or to your home. The built-in test switch accurately 
tests the smoke alarm's operation as required by Underwriters Laboratories Inc. (UL).

IMPORTANT CONSIDERATIONS

YOUR ALARM HAS BEEN DESIGNED WITH A PRODUCT END-OF-SERVICE LIFE WARNING 
WHICH WILL SOUND AFTER APPROXIMATELY 10 YEARS OF OPERATION FROM INITIAL 
POWER UP.

NOTE: MANUFACTURER RECOMMENDS REPLACEMENT OF THIS ALARM 10 YEARS AFTER 
DATE OF INSTALLATION. NOTE: NUMEROUS ALARMS OR PROLONGED ALARMING IS 
NOT TYPICAL AND WILL CONSUME THE BATTERY CAPACITY, SHORTENING THE LIFE 
OF THIS PRODUCT.

Page 6

END-OF-SERVICE LIFE NOTIFICATION:

 A majority of home fire deaths are a result of no smoke 

alarms or no 

working

 smoke alarms. In addition to the "replace by date" stamped on the back of 

your alarm, your alarm contains a unique audible end-of-service life notification feature. When it 
is time to replace your alarm, which is after approximately 10 years of operation from initial power 
up, the alarm will sound 2 chirps approx. every 60 seconds and the red LED will blink on once 
approx. every 2 minutes. The alarm should be replaced immediately.

ALARM ORIGINATION: 

The  QUICK  FIND

®

  feature  will  allow  you  to  immediately  locate  the 

originating alarm (once the alarm has stopped sounding). To initiate QUICK FIND

®

, press the Test/

Silence button on each alarm. After releasing the button, the originating alarm will continue to sound 
for 60 seconds. It is necessary to test each alarm to determine the originating alarm.

RESET:

 

To reset the QUICK FIND

®

 Alarm Origination condition, press and hold the Test/

Silence button on each alarm for at least 10 seconds and then release. This will clear alarm 
origination indicator. Reset after each alarm activation.

Содержание Sensing Plus AMI3051S

Страница 1: ...which could help protect you and your family This alarm detects products of combustion using a multi criteria sensor TABLE OF CONTENTS PAGE Smoke Alarm Limitations and Functions 2 Recommended Locatio...

Страница 2: ...LARMS ARE NOT A SUBSTITUTE FOR INSURANCE Homeowners and renters alike should continue to insure their lives and properties l SMOKE ALARMS CANNOT DETECT FIRES IF THE SMOKE DOES NOT REACH THEM Smoke fro...

Страница 3: ...er than 1 ft in 8 ft 1 m in 8 m horizontally shall be located within 36 in 914 mm of the high side of the ceiling but not closer than 4 in 102 mm from the adjoining wall surface Tray Shaped Ceilings S...

Страница 4: ...r operation This alarm will not work until it is activated and properly installed This alarm should be tested immediately after installation and then tested weekly after that If the alarm ever fails t...

Страница 5: ...itions that when you press the Test Silence button you will experience a delay of approx 10 15 seconds before the alarm sounds This delay occurs if the Test Silence button is pressed during a self dia...

Страница 6: ...or any other chemical on or near your alarm DO NOT disassemble or attempt to clean inside the alarm This alarm contains no serviceable parts If the alarm becomes contaminated by excessive dirt or gre...

Страница 7: ...4 turn 6 This will discharge the alarm battery and stop the alarm chirping after approximately one minute The alarm is now ready for disposal 7 The deactivation key should not be removed and the alarm...

Страница 8: ...m Code NFPA 72 reads as follows 29 8 1 Required Detection Where required by applicable laws codes or standards for a specific type of occupancy approved single and multiple station smoke alarms shall...

Страница 9: ...precautions if an alarm sounds by calling an Emergency Service and getting out of the home 3 Beeps 2 second pause Repeat Silence Feature is activated by pressing and releasing the Test Silence button...

Страница 10: ...r replacement of this alarm under the terms of this Warranty contact the Customer Service Department at 800 390 4321 extension 238 to obtain the current postage and handling fees USI does not warrant...

Отзывы: