OPERATION:

 The smoke alarm is operating once the battery power is connected by removing the 

pull-tab. When products of combustion are sensed, the alarm sounds a loud alarm which continues 
until the air is cleared.
This alarm incorporates the NFPA recognized horn signal for evacuation. During alarm mode, the 
horn produces three beeps followed by a two second pause and then continually repeats.

READY/ACTIVE CONDITION:

 The red LED blinks on once approx. every 2 minutes to indicate 

the alarm is properly functioning.

ALARM CONDITION:

 The alarm emits a loud, pulsating alarm sound and the red LED blinks on 

in sync with horn.

NUISANCE ALARMS:

 

The smoke alarm is designed to minimize nuisance alarms. Smoking will 

not normally set off the alarm unless smoke is blown directly into the smoke alarm. Combustion 
particles from cooking may set off the alarm if the smoke alarm is located close to the kitchen cooking 
surface. Large quantities of combustion particles are generated from spills or broiling.
If the smoke alarm does sound, check for fires first. If a fire is discovered, get out and call the fire 
department. If no fire is present, check to see if one of the reasons listed above may have caused 
the alarm. Use the Silence Feature if it is a nuisance alarm, or reset the alarm by pressing and 
holding the Test/Silence button for ten seconds. Refer to RESET below.

NOTE:

  It  is  best  to  "reset"  the  alarms  before  initial  test  is  performed.  See  below  for  Reset 

procedures.

TESTING:

 Test  by  pressing  the Test/Silence  button  on  the  smoke  alarm  cover  until  the  alarm 

sounds, then release. The alarm sounds if all electronic circuitry, horn and battery are working. If 
no alarm sounds, the alarm may have a power supply failure. 

Test the smoke alarm weekly to 

assure proper operation. IMPORTANT: 

Under normal conditions, the test button should sound 

the alarm immediately after it is pressed. There are special conditions that, when you press the 
Test/Silence button, you will experience a delay of approx. 10-15 seconds before the alarm sounds. 
This delay occurs if the Test/Silence button is pressed during a self-diagnostic period. This may 
occur after initial power up. Retest after 10-15 seconds.

NOTE:

 Actuation of the test button must be by use of a person’s finger or thumb. Use of any other 

instrument is strictly prohibited.

2.  Insert the pin into the hole in the side of the alarm after the alarm has been installed on the 

mounting plate. Refer to the diagram below for correct placement.

TO DEACTIVATE THE LOCKING FEATURES:

 To remove the smoke alarm for cleaning or servicing, 

you must first remove the locking pin, if it has been installed.
1.  Use long nose pliers to pull the locking pin out of the hole.
2.  It is now possible to remove the smoke alarm.

OPTIONAL TAMPER RESISTANT FEATURE:

 The tamper resistant locking feature for this model 

deters someone from removing the alarm from the mounting bracket. The breakaway locking pin 
is clearly marked and molded into the mounting bracket. Refer to Figure 1.

TO ACTIVATE THE ALARM LOCKING FEATURE:

 Do not activate the locking feature until you 

have activated the battery, mounted the smoke alarm to the bracket and tested the smoke alarm. 
Refer to OPERATION, TESTING & MAINTENANCE instructions on Page 5.

Failure to properly install and activate this alarm will prevent proper operation of this alarm 
and will prevent its response to fire hazards.

Test the alarm following installation and weekly thereafter. The built-in test switch accurately tests 
the alarm operation as required by ANSI/UL217 Standards for Safety. If, at any time, you test the 
alarm and it does not perform as described, replace it immediately. 

CAUTION:

 Due to the loudness 

of the alarm, we suggest that you place your fingers over the sounder opening while testing your 
alarm. Continuous exposure to the high sound level of this alarm over an extended period of time 
may cause hearing loss.

1.  Detach the breakaway alarm locking pin from the mounting bracket.

FIGURE 1

ALARM/BRACKET
LOCKING PIN

INSERT ALARM 

LOCKING PIN HERE

(optional)

Содержание Sensing Plus AMI3051S

Страница 1: ...which could help protect you and your family This alarm detects products of combustion using a multi criteria sensor TABLE OF CONTENTS PAGE Smoke Alarm Limitations and Functions 2 Recommended Locatio...

Страница 2: ...LARMS ARE NOT A SUBSTITUTE FOR INSURANCE Homeowners and renters alike should continue to insure their lives and properties l SMOKE ALARMS CANNOT DETECT FIRES IF THE SMOKE DOES NOT REACH THEM Smoke fro...

Страница 3: ...er than 1 ft in 8 ft 1 m in 8 m horizontally shall be located within 36 in 914 mm of the high side of the ceiling but not closer than 4 in 102 mm from the adjoining wall surface Tray Shaped Ceilings S...

Страница 4: ...r operation This alarm will not work until it is activated and properly installed This alarm should be tested immediately after installation and then tested weekly after that If the alarm ever fails t...

Страница 5: ...itions that when you press the Test Silence button you will experience a delay of approx 10 15 seconds before the alarm sounds This delay occurs if the Test Silence button is pressed during a self dia...

Страница 6: ...or any other chemical on or near your alarm DO NOT disassemble or attempt to clean inside the alarm This alarm contains no serviceable parts If the alarm becomes contaminated by excessive dirt or gre...

Страница 7: ...4 turn 6 This will discharge the alarm battery and stop the alarm chirping after approximately one minute The alarm is now ready for disposal 7 The deactivation key should not be removed and the alarm...

Страница 8: ...m Code NFPA 72 reads as follows 29 8 1 Required Detection Where required by applicable laws codes or standards for a specific type of occupancy approved single and multiple station smoke alarms shall...

Страница 9: ...precautions if an alarm sounds by calling an Emergency Service and getting out of the home 3 Beeps 2 second pause Repeat Silence Feature is activated by pressing and releasing the Test Silence button...

Страница 10: ...r replacement of this alarm under the terms of this Warranty contact the Customer Service Department at 800 390 4321 extension 238 to obtain the current postage and handling fees USI does not warrant...

Отзывы: