Analog input wiring, voltage 

 

Shields should be connected at the signal’s source. 
The 0V signal of the analog input must be connected to the controller’s 0V. 

 

npn Outputs 

 

Power Supply 

The controller requires an external 24VDC power supply. 

 

A non-isolated power supply can be used if a 0V signal is connected to the chassis. 

You must use an external circuit protection device. 
Install an external circuit breaker. Guard against short-
circuiting in external wiring. 
Double-check all wiring before turning on the power 
supply. 
Do not connect either the ‘Neutral or ‘Line’ signal of the 
110/220VAC to device’s 0V pin. 
In the event of voltage fluctuations or non-conformity to 
voltage power supply specifications, connect the device 
to a regulated power supply. 

Earthing the Power Supply 

To maximize system performance, avoid electromagnetic interference by: 

Mounting the controller on a metal panel. 
Earthing the controller’s power supply: connect one end of a 14 AWG wire to the chassis 
signal; connect the other end to the panel. 

Note: If possible, the wire used to earth the power supply should not exceed 10 cm in 
length.  However, it is recommended to earth the controller in all cases. 

 

Содержание Vision OPLC V130-33-T38

Страница 1: ...Os Information Mode This mode enables you to View Edit operand values COM port settings RTC and screen contrast brightness settings Stop initialize and reset the PLC To enter Information Mode press the i button for several seconds Programming Software Utilities The Unitronics Setup CD contains VisiLogic software and other utilities VisiLogic Easily configure hardware and write both HMI and Ladder ...

Страница 2: ... of this product according to local and national standards and regulations Only qualified service personnel should open this device or carry out repairs Failure to comply with appropriate safety guidelines can cause severe injury or property damage Do not attempt to use this device with parameters that exceed permissible levels To avoid damaging the system do not connect disconnect the device when...

Страница 3: ...oller into the cut out ensuring that the rubber seal is in place 3 Push the 2 mounting brackets into their slots on the sides of the controller as shown in the figure to the right 4 Tighten the bracket screws against the panel Hold the bracket securely against the unit while tightening the screw 5 When properly mounted the controller is squarely situated in the panel cut out as shown in the figure...

Страница 4: ...N m 5 kgf cm Do not use tin solder or any substance on stripped wire that might cause the wire strand to break Install at maximum distance from high voltage cables and power equipment Use crimp terminals for wiring use 26 12 AWG wire 0 13 mm 2 3 31 mm2 1 Strip the wire to a length of 7 0 5mm 0 250 0 300 inches 2 Unscrew the terminal to its widest position before inserting a wire 3 Insert the wire ...

Страница 5: ... and 3 can function as either counter reset as normal digital inputs or as part of a shaft encoder Input Jumper Settings The tables below show how to set a specific jumper to change input functionality To access the I O jumpers you must open the controller according to the instructions beginning on page 9 Incompatible jumper settings and wiring connections may seriously damage the controller Digit...

Страница 6: ... 6 Unitronics Input wiring npn sink Input wiring pnp source HSC input wiring npn sink HSC input wiring pnp source Shaft encoder Analog input wiring current 2 wire Analog input wiring current 3 wire Analog input wiring current 4 wire ...

Страница 7: ... all wiring before turning on the power supply Do not connect either the Neutral or Line signal of the 110 220VAC to device s 0V pin In the event of voltage fluctuations or non conformity to voltage power supply specifications connect the device to a regulated power supply Earthing the Power Supply To maximize system performance avoid electromagnetic interference by Mounting the controller on a me...

Страница 8: ...ial devices and applications such as SCADA Use RS485 to create a multi drop network containing up to 32 devices Pinouts The pinouts below show the PLC port signals To connect a PC to a port that is set to RS485 remove the RS485 connector and connect the PC to the PLC via the programming cable Note that this is possible only if flow control signals are not used which is the standard case RS232 RS48...

Страница 9: ...ler according to the instructions beginning on page 9 Opening the Controller Before performing these actions touch a grounded object to discharge any electrostatic charge Avoid touching the PCB board directly Hold the PCB board by its connectors 1 Turn off the power supply disconnect and dismount the controller 2 The back cover of the controller comprises 4 screws located in the corners Remove the...

Страница 10: ...discontinue or change the features designs materials and other specifications of its products and to either permanently or temporarily withdraw any of the forgoing from the market All information in this document is provided as is without warranty of any kind either expressed or implied including but not limited to any implied warranties of merchantability fitness for a particular purpose or non i...

Отзывы: