Unitronics Vision OPLC V1040-T20B Скачать руководство пользователя страница 7

Installation Guide 

Vision™ OPLC™  V1040-T20B 

 

Unitronics 

 

 

 

Wiring 

 

  Do not touch live wires. 

 

  Install an external circuit breaker. Guard against short-circuiting in external wiring. 

  Use appropriate circuit protection devices. 

  Unused pins should not be connected. Ignoring this directive may damage the device. 

  Double-check all wiring before turning on the power supply. 

Caution 

  To avoid damaging the wire, do not exceed a maximum torque of 0.5 N·m (5 kgf·cm). 

  Do not use tin, solder, or any substance on stripped wire that might cause the wire 

strand to break. 

  Install at maximum distance from high-voltage cables and power equipment. 

 

Wiring Procedure 

Use crimp terminals for wiring; use 26-12 AWG wire (0.13 mm 

2

–3.31 mm

2

).  

1. Strip the wire to a length of 7±0.5mm (0.250

–0.300 inches).  

2. Unscrew the terminal to its widest position before inserting a wire.  

3. Insert the wire completely into the terminal to ensure a proper connection. 

4. Tighten enough to keep the wire from pulling free. 

 

Power Supply 

The controller V1040-T20B requires either an external 12 or 24VDC power supply.  
Permissible input voltage range: 10.2-28.8VDC, with less than 10% ripple.  

 

  The power supply must include double insulation. Outputs must be rated as 

SELV/PELV/Class 2/Limited Power. 

  Do not connect either the 

‘Neutral or ‘Line’ signal of the 110/220VAC to device’s 0V pin. 

 

  Install an external circuit breaker. Guard against short-

circuiting in external wiring. 

  Double-check all wiring before turning on the power 

supply. 

  In the event of voltage fluctuations or non-conformity to 

voltage power supply specifications, connect the device 
to a regulated power supply. 

 

 

Earthing the OPLC  

To maximize system performance, avoid electromagnetic interference by: 

  Mounting the controller on a metal panel. 

  Connect the functional earth terminal of the OPLC, and the common and ground lines of 

I/Os, directly to the earth ground of your system.

 

  For ground wiring, use the shortest and thickest possible wire.

 

  

 

Содержание Vision OPLC V1040-T20B

Страница 1: ...troller to provide an on board I O configuration I O Expansion Modules Local or remote I Os may be added via expansion port or CANbus Installation instructions and other data may be found in the module s technical specification sheet Information Mode This mode enables you to Calibrate the touchscreen View Edit operand values COM port settings RTC and screen contrast brightness settings Stop initia...

Страница 2: ...uct the user must read and understand this document All examples and diagrams are intended to aid understanding and do not guarantee operation Unitronics accepts no responsibility for actual use of this product based on these examples Please dispose of this product according to local and national standards and regulations Only qualified service personnel should open this device or carry out repair...

Страница 3: ...ect equipment unless power has been switched off or the area is known to be non hazardous WARNING Exposure to some chemicals may degrade the sealing properties of material used in Relays This equipment must be installed using wiring methods as required for Class I Division 2 as per the NEC and or CEC Panel Mounting For programmable controllers that can be mounted also on panel in order to meet the...

Страница 4: ...sition à certains produits chimiques peut dégrader les propriétés des matériaux utilisés pour l étanchéité dans les relais Cet équipement doit être installé utilisant des méthodes de câblage suivant la norme Class I Division 2 NEC et ou CEC Montage de l écran Pour les automates programmables qui peuvent aussi être monté sur l écran pour pouvoir être au standard UL l écran doit être monté dans un c...

Страница 5: ...ver on the rear of the controller 1 Remove the battery cover shown on page 6 The polarity is marked on the battery holder and on the battery 2 Insert the battery ensuring that the polarity symbol on the battery is facing up aligned with the symbol on the holder 3 Replace the battery cover Mounting Dimensions Note that the LCD screen may have a single pixel that is permanently either black or white...

Страница 6: ...oller into the cut out ensuring that the rubber seal is in place 3 Push the 8 mounting brackets into their slots on the sides of the controller as shown in the figure to the right 4 Tighten the bracket screws against the panel Hold the bracket securely against the unit while tightening the screw 5 When properly mounted the controller is squarely situated in the panel cut out as shown below Caution...

Страница 7: ...to the terminal to ensure a proper connection 4 Tighten enough to keep the wire from pulling free Power Supply The controller V1040 T20B requires either an external 12 or 24VDC power supply Permissible input voltage range 10 2 28 8VDC with less than 10 ripple The power supply must include double insulation Outputs must be rated as SELV PELV Class 2 Limited Power Do not connect either the Neutral o...

Страница 8: ...ontaining up to 32 devices Pinouts The pinouts below show PLC port signals To connect a PC to a port that is set to RS485 remove the RS485 connector and connect the PC to the PLC via the programming cable Note that this is possible only if flow control signals are not used which is the standard case RS232 RS485 Controller Port Pin Description Pin Description Pin 1 1 DTR signal 1 A signal 2 0V refe...

Страница 9: ...Line the circular guidelines on the Snap in I O Module with the slots on the controller as shown below 3 Apply even pressure on all 4 corners until you hear a distinct click The module is now installed Check that all sides and corners are correctly aligned Removing a Snap in I O Module 1 Locate the four buttons on the sides of the controller two on either side 2 Press the buttons and hold them dow...

Страница 10: ...r external devices CANLayer 2 J1939 Unitronics proprietary UniCAN 60 controllers 512 data bytes per scan The CANbus port is galvanically isolated CANbus Wiring Use twisted pair cable DeviceNet thick shielded twisted pair cable is recommended Network terminators These are supplied with the controller Place terminators at each end of the CANbus network Resistance must be set to 1 121Ω 1 4W Connect g...

Страница 11: ... brightness Via software Store value to SI 9 Keypad Displays virtual keyboard when the application requires data entry Notes 1 Note that the LCD screen may have a single pixel that is permanently either black or white Keypad Number of keys 9 programmable function keys Key type Metal dome sealed membrane switch Program Memory size Application Logic 2MB Images 80MB Fonts 1MB Operand type Quantit y S...

Страница 12: ...5200 bps Cable USB 2 0 compliant up to 3m CANbus port 1 Nodes CANopen Unitronics CANbus protocols 127 60 Power requirements 24VDC 4 40mA max per unit See Note 5 Galvanic isolation Yes between CANbus and controller Cable length baud rate See Note 5 25 m 100 m 250 m 500 m 500 m 1000 m 1000 m 1 Mbit s 500 Kbit s 250 Kbit s 125 Kbit s 100 Kbit s 50 Kbit s 20 Kbit s If you require cable lengths over 50...

Страница 13: ...oducts at the date of printing Unitronics reserves the right subject to all applicable laws at any time at its sole discretion and without notice to discontinue or change the features designs materials and other specifications of its products and to either permanently or temporarily withdraw any of the forgoing from the market All information in this document is provided as is without warranty of ...

Отзывы: