background image

 

UniStream

®

 PLC 

 

 

Unitronics 

 

 

HMI 

HMI screens are designed in UniLogic. In addition to the HMI screens, 

UniStream® PLCs offer built-in HMI features, including: 

 

UniApps™: Access & ed

it data, monitor, troubleshoot, debug, 

and more 

 

Security: Multi-level password protection 

 

Alarms: Built-in system, ANSI/ISA standards 

USB Action 

files

 

Programmers can create files in UniLogic and save them to a USB mass 

storage device, such as a flash drive. This enables the end user to 

implement certain actions such as to update firmware, update network 

settings, download applications, extract log files and more. 

Comparison 

table 

Feature 

B10/C10 

Pro 

B5/C5 

Standard 

B3/C3 

Basic 

I/O Expansion via Uni-I/O  

Yes 

No 

Remote I/O Expansion via 

Ethernet  I/O Adapter 

(URB) 

Up to 8 

VFD 

32 

MicroSD 

Yes 

No* 

Add-on COM modules 

System Memory 

6GB 

3GB 

3GB 

 

MODBUS Slaves 

Unlimited 

Up to 8 

Ethernet/IP Scanners 

16 

Ethernet/IP Adapters 

32 

Web Server 

Yes 

No 

No 

SQL Client 

Yes 

No 

No 

 

MQTT 

Yes 

 

PID Loops 

64 

 

Data Sampler/Trends 

Yes 

No 

 

CSV files: creating/ 

reading  

Yes 

No 

 

FTP, server/client 

Yes 

No 

 

Saving Data Tables to SD 

Yes 

No* 

 

Screenshots 

Yes 

No 

 

Sending email 
attachments 

Yes 

No 

 

USB device (programming 

port) 

Yes 

No** 

* Note that B3/C3 models do not support features requiring SD cards. In addition, Alarm 

History is not retained after PLC reset. 
** Note that B3/C3 models may be programmed only via Ethernet cable.  

 

 

 

Содержание UniStream USC-B10-R38

Страница 1: ...rends and Gauges auto tuned PID data tables data sampling and Recipes UniApps Access edit data monitor troubleshoot debug and more Security Multi level password protection Alarms Built in system ANSI ISA standards COM Options Built in ports 2 Ethernet 1 USB host 1 USB device port Add on ports UAC CB available by separate order 1 CANbus port may be added to all models RS232 485 ports according to m...

Страница 2: ... Comparison table Feature B10 C10 Pro B5 C5 Standard B3 C3 Basic I O Expansion via Uni I O Yes No Remote I O Expansion via Ethernet I O Adapter URB Up to 8 1 VFD 32 2 MicroSD Yes No Add on COM modules 3 2 System Memory 6GB 3GB 3GB MODBUS Slaves Unlimited Up to 8 Ethernet IP Scanners 16 1 Ethernet IP Adapters 32 8 Web Server Yes No No SQL Client Yes No No MQTT Yes PID Loops 64 2 Data Sampler Trends...

Страница 3: ...nal standards and regulations This product should be installed only by qualified personnel Failure to comply with appropriate safety guidelines can cause severe injury or property damage Do not attempt to use this device with parameters that exceed permissible levels Do not connect disconnect the device when power is on Environmental Considerations Ventilation 10mm space is required between the de...

Страница 4: ...Ds 5 Top Door Closed Covers the Confirm button and the USB Host port 6 Bottom Door Closed Covers the internal door protecting the battery and microSD slot 7 Uni COM Jack Connection port for Uni COM CB modules Shipped covered leave cover in place when not in use Top View 8 Ethernet ports Two ports for Ethernet communications 9 Input Output connection points Model dependent Present in models with bu...

Страница 5: ...roSD cards 17 Battery Holder The battery is supplied installed the user must remove the pull tab during installation These are available by separate order Installation Space Considerations Allocate space for The controller I O wiring Access to ports jacks and the microSD card slot Any modules that will be installed ensure you allow space to install uninstall modules Module dimensions and installat...

Страница 6: ...he event of power off the battery must be connected First Use The battery is protected by the PLC s bottom and inner door The battery is supplied installed inside the unit with a plastic tab preventing contact Pull out this tab before using the device Battery Installation and Replacement Use proper precautions to prevent Electro Static Discharge ESD while servicing the battery Caution To preserve ...

Страница 7: ... such as a fuse or circuit breaker to avoid excessive currents into the power supply connection point Unused points should not be connected unless otherwise specified Ignoring this directive may damage the device Double check all wiring before turning on the power supply Caution To avoid damaging the wire do not exceed a maximum torque of All terminal blocks except T42 outputs terminal block 0 5 N...

Страница 8: ...se the shortest and thickest wires possible less than 1m 3 3 in length minimum thickness 14 AWG 2 mm2 Connect the power supply 0V to the earth of the system Earthing the cables shield Connect the cable shield to the earth of the system preferably to the metal cabinet chassis Note that the shield must be connected only at one end of the cable it is recommended to earth the shield at the PLC side Ke...

Страница 9: ... Input connection points Bottom group Output connection points The function of certain I Os may be adapted via wiring and software settings USC xx R38 USC xx T42 Wiring the Digital Inputs The digital inputs are arranged in two isolated groups I0 I9 share common CM0 I10 I23 share common CM2 Each group may be wired together as sink or source Inputs I10 I17 can be configured as either normal digital ...

Страница 10: ...digital Pulse Normal digital Channel 3 Channel 4 I14 I15 I16 I17 Quadrature Phase A Phase B Phase A Phase B Pulse Direction Pulse Direction Pulse Direction Pulse Pulse Normal digital Pulse Normal digital Input wiring sink Input wiring source High Speed Input wiring sink High Speed Input wiring source NOTE Use sink input wiring to connect a sourcing pnp device Use source input wiring to connect a s...

Страница 11: ... offers two modes voltage or current You can set each input independently The mode is determined by the hardware configuration within the software application Note that if for example you wire the input to current you must also set it to current in the software application Voltage Differential Single ended Current 2 wire 3 wire 4 wire ...

Страница 12: ...alled devices according to the device s installation guide 3 Unscrew and remove the mounting brackets taking care to support the device to prevent it from falling during this procedure The information in this document reflects products at the date of printing Unitronics reserves the right subject to all applicable laws at any time at its sole discretion and without notice to discontinue or change ...

Отзывы: