background image

 

UniStream

®

 PLC 

 

12 

 

Unitronics 

 

Wiring the Relay Outputs (USC-xx-R38)

 

 

 

To avoid risk of fire or property damage, always use a limited current source or 

connect a current limiting device in series with the relay contacts 

 

The relay outputs are arranged in two 

isolated groups: 
O0-O5 share the common return CM3. 
O6-O11 share the common return CM4. 

 

 

Increasing Contact Life Span 

To increase the life span of the relay contacts 

and protect the controller from potential 

damage by reverse EMF, connect: 

 

a clamping diode in parallel with each 

inductive DC load, 

 

a RC snubber circuit in parallel with each 

inductive AC load

 v

 

 

 

 

   

 

Wiring the Source Transistor Outputs (USC-xx-T42) 

 

Output’s power supply

 

 

 

 

The use of any of the outputs requires 

an external 24VDC power supply as 
shown in the accompanying figure. 

Outputs  

Connect the +VO and 0VO terminals as 

shown in the accompanying figure. 
O0-O15 share common return 0VO.

 

 

Installing Uni-

I/O™ & Uni

-

COM™ 

Modules 

Refer to the Installation Guides provided with these modules. 

 

 

 

 

Turn off system power before connecting or disconnecting any modules or devices. 

 

Use proper precautions to prevent Electro-Static Discharge (ESD). 

 

Uninstalling the Controller 

1.  Disconnect the power supply. 
2.  Remove all wiring and disconnect any installed devices 

according to the device’s 

installation guide. 

3.  Unscrew and remove the mounting brackets, taking care to support the device to 

prevent it from falling during this procedure. 

 

The information in this document reflects products at the date of printing. Unitronics reserves the right, subject to all applicable laws, at any time, at its sole 
discretion, and without notice, to discontinue or change the features, designs, materials and other specifications of its products, and to either permanently or 

temporarily withdraw any of the forgoing from the market. 
All information in this document is provided "as is" without warranty of any kind, either expressed or implied, including but not limited to any implied 
warranties of merchantability, fitness for a particular purpose, or non-infringement. Unitronics assumes no responsibility for errors or omissions in the 

information presented in this document. In no event shall Unitronics be liable for any special, incidental, indirect or consequential damages of any kind, or 

any damages whatsoever arising out of or in connection with the use or performance of this information. 
The tradenames, trademarks, logos and service marks presented in this document, including their design, are the property of Unitronics (1989) (R"G) Ltd. or 
other third parties and you are not permitted to use them without the prior written consent of Unitronics or such third party as may own them 

DOC32003-B0 REV. B01 11/21 

 

Содержание UniStream USC-B10-R38

Страница 1: ...rends and Gauges auto tuned PID data tables data sampling and Recipes UniApps Access edit data monitor troubleshoot debug and more Security Multi level password protection Alarms Built in system ANSI ISA standards COM Options Built in ports 2 Ethernet 1 USB host 1 USB device port Add on ports UAC CB available by separate order 1 CANbus port may be added to all models RS232 485 ports according to m...

Страница 2: ... Comparison table Feature B10 C10 Pro B5 C5 Standard B3 C3 Basic I O Expansion via Uni I O Yes No Remote I O Expansion via Ethernet I O Adapter URB Up to 8 1 VFD 32 2 MicroSD Yes No Add on COM modules 3 2 System Memory 6GB 3GB 3GB MODBUS Slaves Unlimited Up to 8 Ethernet IP Scanners 16 1 Ethernet IP Adapters 32 8 Web Server Yes No No SQL Client Yes No No MQTT Yes PID Loops 64 2 Data Sampler Trends...

Страница 3: ...nal standards and regulations This product should be installed only by qualified personnel Failure to comply with appropriate safety guidelines can cause severe injury or property damage Do not attempt to use this device with parameters that exceed permissible levels Do not connect disconnect the device when power is on Environmental Considerations Ventilation 10mm space is required between the de...

Страница 4: ...Ds 5 Top Door Closed Covers the Confirm button and the USB Host port 6 Bottom Door Closed Covers the internal door protecting the battery and microSD slot 7 Uni COM Jack Connection port for Uni COM CB modules Shipped covered leave cover in place when not in use Top View 8 Ethernet ports Two ports for Ethernet communications 9 Input Output connection points Model dependent Present in models with bu...

Страница 5: ...roSD cards 17 Battery Holder The battery is supplied installed the user must remove the pull tab during installation These are available by separate order Installation Space Considerations Allocate space for The controller I O wiring Access to ports jacks and the microSD card slot Any modules that will be installed ensure you allow space to install uninstall modules Module dimensions and installat...

Страница 6: ...he event of power off the battery must be connected First Use The battery is protected by the PLC s bottom and inner door The battery is supplied installed inside the unit with a plastic tab preventing contact Pull out this tab before using the device Battery Installation and Replacement Use proper precautions to prevent Electro Static Discharge ESD while servicing the battery Caution To preserve ...

Страница 7: ... such as a fuse or circuit breaker to avoid excessive currents into the power supply connection point Unused points should not be connected unless otherwise specified Ignoring this directive may damage the device Double check all wiring before turning on the power supply Caution To avoid damaging the wire do not exceed a maximum torque of All terminal blocks except T42 outputs terminal block 0 5 N...

Страница 8: ...se the shortest and thickest wires possible less than 1m 3 3 in length minimum thickness 14 AWG 2 mm2 Connect the power supply 0V to the earth of the system Earthing the cables shield Connect the cable shield to the earth of the system preferably to the metal cabinet chassis Note that the shield must be connected only at one end of the cable it is recommended to earth the shield at the PLC side Ke...

Страница 9: ... Input connection points Bottom group Output connection points The function of certain I Os may be adapted via wiring and software settings USC xx R38 USC xx T42 Wiring the Digital Inputs The digital inputs are arranged in two isolated groups I0 I9 share common CM0 I10 I23 share common CM2 Each group may be wired together as sink or source Inputs I10 I17 can be configured as either normal digital ...

Страница 10: ...digital Pulse Normal digital Channel 3 Channel 4 I14 I15 I16 I17 Quadrature Phase A Phase B Phase A Phase B Pulse Direction Pulse Direction Pulse Direction Pulse Pulse Normal digital Pulse Normal digital Input wiring sink Input wiring source High Speed Input wiring sink High Speed Input wiring source NOTE Use sink input wiring to connect a sourcing pnp device Use source input wiring to connect a s...

Страница 11: ... offers two modes voltage or current You can set each input independently The mode is determined by the hardware configuration within the software application Note that if for example you wire the input to current you must also set it to current in the software application Voltage Differential Single ended Current 2 wire 3 wire 4 wire ...

Страница 12: ...alled devices according to the device s installation guide 3 Unscrew and remove the mounting brackets taking care to support the device to prevent it from falling during this procedure The information in this document reflects products at the date of printing Unitronics reserves the right subject to all applicable laws at any time at its sole discretion and without notice to discontinue or change ...

Отзывы: