UniStream

®

 PLC 

 

 

 

Before You Begin 

Before installing the device, the user must: 

 

Read and understand this document. 

 

Verify the Kit Contents. 

 

Alert Symbols and General Restrictions 

When any of the following symbols appear, read the associated information carefully. 

Symbol 

Meaning 

Description 

 

Danger 

The identified danger causes physical and property damage. 

 

Warning 

The identified danger could cause physical and property damage. 

Caution 

Caution 

Use caution. 

 

All examples and diagrams are intended to aid understanding, and do not guarantee 

operation. Unitronics accepts no responsibility for actual use of this product based on 

these examples. 

 

Please dispose of this product according to local and national standards and regulations. 

 

This product should be installed only by qualified personnel. 

 

 

Failure to comply with appropriate safety guidelines can cause severe injury or 

property damage. 

 

Do not attempt to use this device with parameters that exceed permissible levels. 

 

Do not connect/disconnect the device when power is on. 

 

 

Environmental Considerations 

 

 

 

 

Ventilation: 10mm space is required between the device top/bottom edges and the 

enclosure’s walls 

 

Do not install in areas with: excessive or conductive dust, corrosive or flammable 

gas, moisture or rain, excessive heat, regular impact shocks or excessive vibration, 

in accordance with the standards and limitations given in the product’s technical 

specification sheet. 

 

Do not place in water or let water leak onto the unit.  

 

Do not allow debris to fall inside the unit during installation. 

 

Install at maximum distance from high-voltage cables and power equipment. 

 

 

 

Unitronics 

 

 

Содержание UniStream PLC Series

Страница 1: ...to tuned PID data tables data sampling and Recipes UniApps Access edit data monitor troubleshoot debug and more Security Multi level password protection Alarms Built in system ANSI ISA standards COM Options Built in ports 2 Ethernet 1 USB host 1 USB device port Add on ports UAC CB available by separate order 1 CANbus port may be added to all models RS232 485 ports according to model technical spec...

Страница 2: ...between B10 B5 and B3 Feature B10 Pro B5 Standard B3 Basic I O Expansion via Uni I O Yes No Remote I O Expansion via Ethernet I O Adapter URB Up to 8 1 VFD 32 2 MicroSD Yes No Add on COM modules 3 2 System Memory 6GB 3GB 3GB MODBUS Slaves Unlimited Up to 8 Ethernet IP Scanners 16 1 Ethernet IP Adapters 32 8 Web Server Yes No No SQL Client Yes No No MQTT Yes PID Loops 64 2 Data Sampler Trends Yes N...

Страница 3: ... and regulations This product should be installed only by qualified personnel Failure to comply with appropriate safety guidelines can cause severe injury or property damage Do not attempt to use this device with parameters that exceed permissible levels Do not connect disconnect the device when power is on Environmental Considerations Ventilation 10mm space is required between the device top bott...

Страница 4: ... Closed Covers the Confirm button and the USB Host port 6 Bottom Door Closed Covers the internal door protecting the battery and microSD slot 7 Uni COM Jack Connection port for Uni COM CB modules Shipped covered leave cover in place when not in use Top View 8 Ethernet ports Two ports for Ethernet communications 9 Input Output connection points Model dependent Present in models with built in I O co...

Страница 5: ... Battery Holder The battery is supplied installed the user must remove the pull tab during installation These are available by separate order Installation Space Considerations Allocate space for The controller I O wiring Access to ports jacks and the microSD card slot Any modules that will be installed ensure you allow space to install uninstall modules Module dimensions and installation instructi...

Страница 6: ...ower off the battery must be connected First Use The battery is protected by the PLC s bottom and inner door The battery is supplied installed inside the unit with a plastic tab preventing contact Pull out this tab before using the device Battery Installation and Replacement Use proper precautions to prevent Electro Static Discharge ESD while servicing the battery Caution To preserve back up value...

Страница 7: ...rmed while power is OFF Use over current protection such as a fuse or circuit breaker to avoid excessive currents into the power supply connection point Unused points should not be connected unless otherwise specified Ignoring this directive may damage the device Double check all wiring before turning on the power supply Caution To avoid damaging the wire use a maximum torque of 0 5 N m 5 kgf cm D...

Страница 8: ...st and thickest wires possible less than 1m 3 3 in length minimum thickness 14 AWG 2 mm2 Connect the power supply 0V to the earth of the system Earthing the cables shield Connect the cable shield to the earth of the system preferably to the metal cabinet chassis Note that the shield must be connected only at one end of the cable it is recommended to earth the shield at the PLC side Keep shield con...

Страница 9: ...f certain I Os may be adapted via wiring and software settings USC Bx R38 USC Bx T42 Wiring the Digital Inputs The digital inputs are arranged in two isolated groups I0 I9 share common CM0 I10 I23 share common CM1 Each group may be wired together as sink or source Inputs I10 I17 can be configured as either normal digital inputs or as high speed inputs that can receive high speed pulse signals from...

Страница 10: ...Normal digital Channel 3 Channel 4 I14 I15 I16 I17 Quadrature Phase A Phase B Phase A Phase B Pulse Direction Pulse Direction Pulse Direction Pulse Pulse Normal digital Pulse Normal digital Input wiring sink Input wiring source High Speed Input wiring sink High Speed Input wiring source NOTE Use sink input wiring to connect a sourcing pnp device Use source input wiring to connect a sinking npn dev...

Страница 11: ...des voltage or current You can set each input independently The mode is determined by the hardware configuration within the software application Note that if for example you wire the input to current you must also set it to current in the software application Voltage Differential Single ended Current 2 wire 3 wire 4 wire Unitronics 11 ...

Страница 12: ...ces according to the device s installation guide 3 Unscrew and remove the mounting brackets taking care to support the device to prevent it from falling during this procedure The information in this document reflects products at the date of printing Unitronics reserves the right subject to all applicable laws at any time at its sole discretion and without notice to discontinue or change the featur...

Отзывы: