background image

05/16 

 

 

 

 

Unitronics 

 

   

 

Digital Outputs, Outputs’ Power Supply 

PNP Outputs 

Relay Outputs 

+VO is the power supply for pnp outputs O5

O6. 

 

 

 

   

  

Increasing contact life span 

To increase the life span of your contacts and protect the unit from potential damage by reverse-
EMF, connect:  

  A clamping diode in parallel with each inductive DC load 

  An RC snubber circuit in parallel with each inductive AC load 

 

AC 

DC 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

The information in this document reflects products at the date of printing. Unitronics reserves the right, subject to all applicable laws, at any time, at its sole 

discretion, and without notice, to discontinue or change the features, designs, materials and other specifications of its products, and to either permanently or 
temporarily withdraw any of the forgoing from the market. 
All information in this document is provided "as is" without warranty of any kind, either expressed or implied, including but not limited to any implied warranties of 

merchantability, fitness for a particular purpose, or non-infringement. Unitronics assumes no responsibility for errors or omissions in the information presented in 
this document. In no event shall Unitronics be liable for any special, incidental, indirect or consequential damages of any kind, or any damages whatsoever arising 

out of or in connection with the use or performance of this information. 
The tradenames, trademarks, logos and service marks presented in this document, including their design, are the property of Unitronics (1989) (R"G) Ltd. or other 

third parties and you are not permitted to use them without the prior written consent of Unitronics or such third party as may own them

 

DOC05013-A3 05/16 

 
 

Содержание Jazz JZ20-J-UN20

Страница 1: ...ations Only qualified service personnel should open this device or carry out repairs Failure to comply with appropriate safety guidelines can cause severe injury or property damage Do not attempt to use this device with parameters that exceed permissible levels To avoid damaging the system do not connect disconnect the device when power is on Environmental Considerations Do not install in areas wi...

Страница 2: ...ure Wiring This equipment is designed to operate only in SELV PELV Class 2 Limited Power environments All power supplies in the system must include double insulation Power supply outputs must be rated as SELV PELV Class 2 Limited Power Do not connect either the Neutral or Line signal of the 110 220VAC to device s 0V pin Do not touch live wires All wiring activities should be performed while power ...

Страница 3: ...and noise interference with input lines used over an extended distance Use wire that is properly sized for the load Earthing the product To maximize system performance avoid electromagnetic interference as follows Use a metal cabinet Connect the 0V terminal directly to the earth ground of the system Use the shortest less than 1m 3 3 ft and thickest 2 08mm 14AWG min wires possible Inputs This model...

Страница 4: ...In either case the npn pnp pins must be connected Input wiring npn sink Input wiring pnp source Input wiring I0 I8 pnp source I9 I10 npn sink Analog Inputs Note Shields should be connected at the signal source Analog Input wiring current 2 wire AN1 Analog Input wiring current 3 wire AN1 Analog Input wiring current 4 wire AN1 Analog Input wiring voltage AN2 and AN3 ...

Страница 5: ...C 328 to 1400 F White Red Yellow Blue K 200 to 1250 C 328 to 2282 F Yellow Red Brown Blue N 200 to 1300 C 328 to 3214 F Orange Red Orange Blue R 0 to 1768 C 32 to 3214 F Black Red White Blue S 0 to 1768 C 32 to 3214 F Black Red White Blue T 200 to 400 C 328 to 752 F Blue Red White Blue Thermocouple 0 use T Input as negative input and T as positive RTD PT100 Sensor 0 use both inputs related to CM s...

Страница 6: ...arily withdraw any of the forgoing from the market All information in this document is provided as is without warranty of any kind either expressed or implied including but not limited to any implied warranties of merchantability fitness for a particular purpose or non infringement Unitronics assumes no responsibility for errors or omissions in the information presented in this document In no even...

Отзывы: