Unitronics IO-ATC8 Скачать руководство пользователя страница 12

IO-ATC8   

I / O   E x p a n s i o n   M o d u l e

 12/03

 

 

12 

Unitronics Industrial Automation 

 

About Unitronics 

Unitronics Industrial Automation Systems has been producing PLCs, automation software and accessory 
devices since 1989.  
Unitronics’ OPLC controllers combine full-function PLCs and HMI operating panels into single, compact units.  
These HMI + PLC devices are programmed in a single, user-friendly environment.  Our clients save I/O points, 
wiring, space, and programming time; elements that translate directly into cost-efficiency. 
Unitronics supports a global network of distributors and sales representatives, as well as a U.S. subsidiary. 
For more information regarding Unitronics products, contact your distributor, Unitronics headquarters via email: 

[email protected]

, or visit the Unitronics website at 

http://www.unitronics.com/

 

 

Under no circumstances will Unitronics be liable or responsible for any consequential damage that may 
arise as a result of installation or use of this equipment, and is not responsible for problems resulting 
from improper or irresponsible use of this device.   
No part of this document may be used for any purpose other than for the purposes specifically indicated 
herein nor may it be reproduced or transmitted in any form or by any means, electronic or mechanical, 
including photocopying and/or recording, for any purpose without written permission from Unitronics. 
The information appearing in this document is for general purposes only. Unitronics makes no warranty 
of any kind with regard to the information appearing in this document, including, but not limited to, 
0implied warranties of merchantability and/or fitness for a particular use or purpose. Unitronics assumes 
no responsibility for the results, direct and/or indirect, of any misuse of the information appearing in this 
document nor for any use of the Unitronics products referred to herein in any manner deviating from the 
recommendations made in this document. Unitronics assumes no responsibility for the use of any parts, 
components, or other ancillary appliances including circuitry other than as recommended hereunder or 
other than that embodied in the Unitronics product. 
Unitronics retains all rights to its proprietary assets including, but not limited to its software products 
which are copyrighted and shall remain the property of Unitronics. Copyright protection claimed includes 
all Forms and matters of copyrightable materials and information legally allowed including but not limited 
to material generated from the software programs which are displayed on the screen of the Unitronics 
products such as styles, templates, icons, screen displays, looks, etc. Duplication and/or any 
unauthorized use thereof are strictly prohibited without prior written permission from Unitronics. 
All brand or product names are used for identification purpose only and may be trademarks or registered 
trademarks of their respective holders. 
Unitronics reserves the right to revise this publication from time to time and to amend its contents and 
related hardware and software at any time.  Technical updates (if any) may be included in subsequent 
editions (if any). 
Unitronics product sold hereunder can be used with certain products of other manufacturers at the user’s 
sole responsibility. 

 
5408-0090-4 

Содержание IO-ATC8

Страница 1: ...d on these examples Please dispose of this product in accordance with local and national standards and regulations Only qualified service personnel should open this device or carry out repairs User safety and equipment protection guidelines This document is intended to aid trained and competent personnel in the installation of this equipment as defined by the European directives for machinery low ...

Страница 2: ...gas moisture or rain excessive heat regular impact shocks or excessive vibration Leave a minimum of 10mm space for ventilation between the top and bottom edges of the device and the enclosure walls Do not place in water or let water leak onto the unit Do not allow debris to fall inside the unit during installation Mounting the Module DIN rail mounting Snap the device onto the DIN rail as shown bel...

Страница 3: ...ng The figure below is not drawn to scale It may be used as a guide for screw mounting the module Mounting screw type either M3 or NC6 32 4mm 5 8mm 0 228 85mm 3 346 80mm 3 15 68 4mm 2 693 93mm 3 66 4mm x2 0 16 0 16 Unitronics Industrial Automation 3 ...

Страница 4: ...le check all wiring before turning on the power supply Wiring Procedures Use crimp terminals for wiring use 26 12 AWG wire 0 13 mm 2 3 31 mm 2 for all wiring purposes 1 Strip the wire to a length of 7 0 5mm 0 250 0 300 inches 2 Unscrew the terminal to its widest position before inserting a wire 3 Insert the wire completely into the terminal to ensure that a proper connection can be made 4 Tighten ...

Страница 5: ...se the appropriate wiring as shown below Open the device and set the jumpers according to the instructions beginning on page 6 The adapter and the COM signals of the analog inputs must be connected to the same 0V signal The COM signals of each channel are internally shorted When set to current voltage each 2 inputs share a common COM signal Unitronics Industrial Automation 5 ...

Страница 6: ...f a specific input first open the device by prying off its back using the blade of a flat bladed screwdriver The insertion points for the screwdriver are located on both sides of the module 1 Open the first side of the device by inserting the blade between the 2 plastic moldings as shown below then gently pushing up 2 Taking care not to damage the cable open the other side of the device by inserti...

Страница 7: ...pansion Module 3 Gently remove the top of the device as shown 4 The jumpers are shown at right Change the jumper settings as required in accordance with the tables shown on the next page Unitronics Industrial Automation 7 ...

Страница 8: ... instructions beginning on page 6 Caution Incompatible jumper settings and wiring may severely damage the device Jumper Thermocouple Voltage Current 1 B A A Input 0 2 B A B 3 B A A Input 1 4 B A B 5 B A A Input 2 6 B A B 7 B A A Input 3 8 B A B 9 B A A Input 4 10 B A B 11 B A A Input 5 12 B A B 13 B A A Input 6 14 B A B 15 B A A Input 7 16 B A B Default factory setting 8 Unitronics Industrial Auto...

Страница 9: ...tomatic Cold junction compensation error 1 5ºC 2 7ºF maximum Absolute maximum rating 0 6VDC Linearity error 0 04 maximum of full scale Error limit 0 4 of input value Warm up time Typically hour 1ºC 1 8ºF repeatability Status indicators OUT OF RANGE Red LEDs Lit when the corresponding input measures an analog value in excess of the input range See Note 4 Thermocouple input ranges Type Temperature r...

Страница 10: ... Relative Humidity RH 5 to 95 non condensing Dimensions WxHxD 80mm x 93mm x 60mm 3 15 x 3 66 x 2 362 Weight 150g 5 3 oz Mounting Either onto a 35mm DIN rail or screw mounted Notes 1 Each input may be set as either thermocouple voltage 0 10V or current 0 20mA 4 20mA via wiring jumper and software settings 2 The device can also measure voltage within the range of 5 to 56mV at a resolution of 0 01mV ...

Страница 11: ...ormula below is used to assign addresses for I O modules used in conjunction with the OPLC X is the number representing a specific module s location 0 7 Y is the number of the input or output on that specific module 0 15 The number that represents the I O s location is equal to 32 x 16 y Examples Input 3 located on expansion module 2 in the system will be addressed as I 67 67 32 2 16 3 Output 4 lo...

Страница 12: ...in this document including but not limited to 0implied warranties of merchantability and or fitness for a particular use or purpose Unitronics assumes no responsibility for the results direct and or indirect of any misuse of the information appearing in this document nor for any use of the Unitronics products referred to herein in any manner deviating from the recommendations made in this document...

Отзывы: