Click on Freeze List to disable and re-enable auto-
scrolling. The On Top check box causes the datalog win-
dow to remain on top of other windows; when un-
checked, other windows may cover up the datalog
window. You may minimize the datalog window at any
time without disrupting the datalogging process.

The Datalog Settings on the menu bar provides for set-
ting the time interval between each point datalogged.
This pull-down menu provides options with a minimum
of five-second intervals. Another option allows stopping
the datalog when the EV2903 detects that the batteries
are idle.

The datalog is saved as a text (.txt) file. If you desire a
plot, we suggest importing into a program such as Micro-
soft Excel.

TM

Standard Operation and Helpful
Hints

Learning the Battery Capacity

Upon initialization of the program and/or inserting a dif-
ferent or new set of batteries, preferably start out by
charging the batteries to “Full.”

Then, discharge the

batteries until “Empty.” Doing this will allow the
EV2903 to “learn” the capacity during the first discharge
cycle.

Batteries

For optimal battery performance, replace batteries as a
complete set. The EV2903 charges the battery stack in
series and not each cell individually. Charging termina-

tion takes place when any cell is fully charged.

Dis-

charging terminates when any cell reaches EDV. Please
refer to the bq2903 data sheet.

Battery Stack Voltage (EDV)

When the bq2903 senses EDV, it disconnects the battery
stack from the load. At this time, the bq2014 Gas Gauge
cannot sense the battery stack voltage, sensing only 0
volts. The battery stack voltage will decrease quickly
due to the averaging routine internal to the bq2014.
When the EV2903 detects EDV, it will display “N/A” as
the Battery Stack Voltage.

Calibrating Battery Stack Voltage

The Battery Stack Voltage display should be within

±

90mV of the true battery stack voltage. For better ac-

curacy, use the Calibration button.

Measure directly

across the battery stack and input this value in the Cali-
bration window. Select Done.

For three- and four-cell calibration, measure directly
across the “+” terminal of battery 1 to the “-” terminal of
battery 3.

Message Status Bar

The lower right-hand corner of the EV2903 screen will
display helpful messages throughout the operation of
the EV2903 program. This message bar will indicate
the number of complete charge and discharge cycles.

Utilities Menu

Use this menu to calibrate the battery stack voltage and
to set the number of data points which the EV2903 uses
to average the current. Benchmarq suggests using 60
data points, which will smooth out graphs showing the
current.

Also in the Utilities menu are options for the Register
window and Flag window. Use these windows to moni-
tor the status of the bq2014. Please refer to the bq2014
data sheet for information concerning these registers
and flags.

5

EV2903

Содержание EV2903

Страница 1: ...of the fast charge rate For safety charging is inhibited if the voltage of any cell is greater than 3 0V during charge or if the voltage of any cell is less than 0 4V when not charging open circuit vo...

Страница 2: ...a bus connection This con nection is made to the RS 232 cable con necting to the serial port of the PC EV2903 Configuration The EV2903 Evaluation Board operates with or without the Interface Program C...

Страница 3: ...started and communication has been established with the EV2903 board If this screen does not appear please refer to Appendix A Troubleshooting for possible solu tions Display and Functional Buttons Th...

Страница 4: ...y the EV2903 While charging the battery stack voltage may appear to jump around This action is due to the voltage being sampled at various times either during the charging pulse or during the idle per...

Страница 5: ...es EDV Please refer to the bq2903 data sheet Battery Stack Voltage EDV When the bq2903 senses EDV it disconnects the battery stack from the load At this time the bq2014 Gas Gauge cannot sense the batt...

Страница 6: ...fter starting the program then communication to the EV2903 Evaluation board has not been established Please check the following Time Out Error On occasion we have noticed that a communication time out...

Страница 7: ...3 U1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 J1 1 2 3 4 5 6 CHARGE RED D1 DONE GREEN D2 VOLT RENEWAL1 VOLT RENEWAL3 1 VOLT RENEWAL2 VOLT RENEWAL4 IRLZ34 Q1 CELL_SEL S1 1 2 3 4 5 6 JP7 JP8 JP9 1N4001 D9 1N400...

Страница 8: ...12 JP3 1 3 2 JP4 1 3 2 JP5 1 3 2 JP6 1 3 2 0 1UF C3 SHEET_1 SHEET_1 SHEET_1 SHEET_1 1N4148 D8 1N4148 D7 1N4148 D3 1N4148 D6 1N4148 D5 P1 1 2 3 4 5 6 7 8 9 CHG DISP DONE SR SB EMPTY DQ REF VSS SEG5 SEG...

Страница 9: ...ONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH PERSONAL INJURY OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE CRITICAL APPLICATIONS TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED AUTHORIZED OR WARRANT...

Отзывы: