Electrical installation
Version: 2022 / V2
Page: 31
BAMOCAR-PG-D3-700-100/160
3.8
Battery connection
Bus circuit capacitor C-ZW:
75 µF at 700 V
Discharge resistance R-ZW:
50 kΩ
Series resistor:
RV approx. 40
Ω
, 50 W
Charging current via K2:
< 20 A
Note:
Enable (RUN) only after the main
contactor K1 is activated.
The max. supply voltage (battery voltage) 740 V=
must not be exceeded at any time (not even for short intervals)!
Danger of damage!
Error message: OVERVOLTAGE
F1 = safety fuse
Programming of an output for the pre-charging:
The output Dout1 switches the relay K3 when the bus circuit voltage (DC-BUS) is greater than the
variable 1.
Note: 12 V variant only on request
Warning:
The power supply connection has no protection against reverse polarity.
If the polarity of the connection is wrong, the device will be destroyed!
Type
Battery connection
Connector
cross-section
Fuse AT
Drive contactor
size
Pin
mm²
AWG
100
6
160
160
16
250
Battery connecting line <2 m. For conductor lengths from 2 to 10m more powerful.
Lay plus-minus cable parallel
Maximum connector cross-section 50 mm², cable lug for M10.