Electrical installations
Version: 2021 / V2
Page: 22
BAMOCAR-PG-D3-700/250, 400
3
Electrical installations
3.1
Important notes
The connection instructions are binding in their assignment of the connections to the plug numbers or
terminal numbers!
All further information on this is non-binding. The input and output lines can be changed and
supplemented taking into account the electrical regulations and guidelines.
The regulations to be observed are
- Connection and operating instructions
- Local regulations
- EC regulations such as EC Machinery Directive 2006/42/EC
- Vehicle regulations ECE-R100, ISO 6469, ISO 26262
- VDE, TÜV and Employer's Liability Insurance Association regulations
Electrical installation only in de-energised state.
Ensure secure activation.
- Insert shorting bar
- Put up warning signs
Installation only by electrotechnically trained personnel
Compare the connection values with the nameplate data.
Ensure correct fusing of the auxiliary voltage supply.
Lay power cables and control cables spatially separated.
Carry out shield connections and earthing measures in accordance with EMC directives.
Use the correct cable cross-sections.
Note polarity!
Attention:
Use external insulation monitors!
•
Poor or undersized cable connections between the battery and the
unit can damage the unit! (Braking energy)
•
The power connection cable from the BAMOCAR to the battery
should be as short as possible. Longer cables lead to dynamic
voltage drops due to the cable impedance. These stress the built-in
capacitors and shorten the service life.