TECHNICAL PARAMETER
MODEL
Volt.
(V~)
Freq
(Hz)
Max input
power
(W)
Max air
speed
(m/s)
Air volume
(m
3
/h)
Noise
(dB)
Net
weight
(Kg)
H
L
H
L
H
L
H
L
ARU-8409
220-240
50
160
110
11
9
1400
1100
57
55
8.5
ARU-8412
200
150
1900
1600
58
56
10
ARU-8415
230
180
2500
2000
59
57
11.5
6
、
ELECTRIC DIAGRAMS
THERMAL CUT-OUT
DOUBLE SPEED SWITCH WIRING DIAGRAM
YELLOW-GREEN
(YELLOW)
BLACK
WHITE
BLUE(BROWN/RED)
YELLOW
ORANGE
C
K
2 OFF
3 HI
1 LO
L
N
DOUBLE SPEED INFRARED REMOTE CONTROLLED WIRING DIAGRAM
THERMAL CUT-OUT
YELLOW-GREEN
WHITE
RECEIVER
I/O
BLUE(BROWN/RED)
C
YELLOW
BLACK
(YELLOW)
ORANGE
RECEIVER
I/C
GREY
WHITE
N
L
BROWN
BLUE
7
、
OPERATION
6.1 Turn on the power switch
6.2 Select the air speed
:
High[H]
、
Low[L]
6.3 According to the installation place adjust the wind direction parts to obtain the best effect.
8
、
CAUTIONS
a)
、
Use the unit at the rated voltage and frequency indicated on the nameplate.
b)
、
Disconnect power source before unit servicing.
c)
、
Routine maintenance must be done every year.
d)
、
Never use petrol, benzene, thinners or any other such chemicals for cleaning the unit.
e)
、
Don’t allow water or any liquid to enter the motor.
f)
、
When power supply comes from a socket, the plug must be in accordance with IEC335-1. When the
power cord is connected directly, polarity switches with contact gap 3mm at least, must be installed in
the power line.
g)
、
In order to avoid danger of injury, electric installation of the air curtain and any kind of needed repair
must be completed only from qualified technician.