background image

Carbon Monoxide Safety Information

25

Consumer Product Safety Commission

The Consumer Product Safety Commission (CPSC) recommends
the use of at least one CO Alarm per household, located near the
sleeping area.

NRC

Ionization type smoke alarms use a very small amount of a
radioactive element in the sensing chamber to enable detection
of visible and invisible combustion products. The radioactive
element is safely contained in the chamber and requires no
adjustments or maintenance. This smoke alarm meets or exceeds
all government standards. It is manufactured and distributed
under license from the U.S. Nuclear Regulatory Commission.

FCC COMPLIANCE STATEMENT

This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However,
there is no guarantee that

interference will not occur in a

particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the
following measures:

—Reorient or relocate the receiving antenna.

—Increase the separation between the equipment and receiver.

—Connect the equipment into an outlet on a circuit different from

that to which the receiver is connected.

—Consult the dealer or an experienced radio/TV technician for help

2553-7201-04(KN-COSM-BA).qxd:_  2017.9.26  11:27 AM  Page 27

Содержание Kidde KN-COSM-BA

Страница 1: ...TO HUSH PUSH TO T E S T W E EKLY For your convenience write down the following information If you call our Product Support Line these are the first questions you will be asked Alarm Model Number loca...

Страница 2: ...6 Carbon Monoxide Alarm Pages 17 Alarm Removal Battery Replacement Pages 18 19 End of Product Life Notification Page 19 General Alarm Maintenance Pages 20 24 Carbon Monoxide Safety Information General...

Страница 3: ...h the unit Your Kidde Smoke CO Alarm was designed to detect both smoke and carbon monoxide from any source of combustion in a residential environment It is not designed for use in a recreational vehic...

Страница 4: ...View FRONT 2 RED AND GREEN LED VOICE SPEAKER ALARM SOUNDER OFF TWIST ON MOVE TO FRESH AIR RED ALARM GREEN STANDBY P U S H TO HUSH PUSH TO T E S T W E EKLY 2553 7201 04 KN COSM BA qxd _ 2017 9 26 11 27...

Страница 5: ...Product View BACK 3 2553 7201 04 KN COSM BA qxd _ 2017 9 26 11 27 AM Page...

Страница 6: ...the verbal warning message WARNING CARBON MONOXIDE This continues until the unit is reset or the CO is eliminated after four minutes the alarm voice pattern will sound once every minute The red Light...

Страница 7: ...duct Support Line at 1 800 880 6788 Test Reset button performs functions See page 14 HUSH Control Feature that silences the unit during nuisance alarm situations see page 15 Peak Level Memory Feature...

Страница 8: ...egies such as protection in place or assisted escape or rescue are necessary Smoke alarms are devices that can provide early warning of possible fires at a reasonable cost however alarms have sensing...

Страница 9: ...r for the presence of CO It will alarm when there are high levels of CO present and when there are low levels of CO present over a longer period of time see page 21 for alarm times When a CO condition...

Страница 10: ...in the main bedroom Verify the alarm can be heard in all sleeping areas Locate an alarm in every room where someone sleeps with the door closed The closed door may prevent an alarm not located in that...

Страница 11: ...moke CO alarms as recommended above refer to Recommended Installation Instructions and figure 1 In older mobile homes that are not well insulated extreme heat or cold can be transferred from the outsi...

Страница 12: ...e sensors to accurately detect these conditions Do not install in peaks of vaulted ceilings A frame ceilings or gabled roofs Keep out of damp and humid areas Install at least one 1 foot away from fluo...

Страница 13: ...hallway when ceiling mounted or horizontal when wall mounted 4 Drill a hole through the pencil marks and use the enclosed screws and anchors to secure use 3 16 drill bit for anchor holes 5 Install the...

Страница 14: ...rnings Three long beeps Verbal warning FIRE Three long beeps Four quick beeps Verbal warning WARNING CARBON MONOXIDE Four quick beeps Weekly testing is required If at anytime it does not perform as de...

Страница 15: ...tton on the alarm will also end the HUSH period NOTE DENSE SMOKE WILL OVERRIDE THE HUSH CONTROL FEATURE AND SOUND A CONTINUOUS ALARM CAUTION BEFORE USING THE ALARM HUSH FEATURE IDENTIFY THE SOURCE OF...

Страница 16: ...e test reset button is pressed thus resetting the alarm HUSH MODE Condition The LED will flash every 2 seconds while the alarm is in HUSH mode Tamper Resist Feature To make your smoke CO alarm tamper...

Страница 17: ...designed to minimize false alarms Cigarette smoke will not normally set off the alarm unless the smoke is blown directly into the alarm Combustion particles from cooking may set off the alarm if loca...

Страница 18: ...r under any circumstance until fire officials give the go ahead There are situations where a smoke alarm may not be effective to protect against fire as stated in the NFPA Standard 72 For instance a s...

Страница 19: ...pliance technician to investigate for sources of CO from fuel burning equipment and appliances and inspect for proper operation of this equipment If problems are identified during this inspection have...

Страница 20: ...LOW BATTERY as described above your unit has malfunctioned Call our toll free Product Support Line at 1 800 880 6788 for instructions on how to return the unit BATTERY INSTALLATION AND REMOVAL To rep...

Страница 21: ...me time A good safety measure is to replace the batteries twice a year at the same time you change your clocks for daylight saving time End of Life Notification Ten 10 years after unit is first powere...

Страница 22: ...n will void your warranty Move the Smoke CO Alarm and place in another location prior to performing any of the following Staining or stripping wood floors or furniture Painting Wall papering Using adh...

Страница 23: ...nes running in an attached garage and using a charcoal gas grill or hibachi in an enclosed area are all possible sources of CO The following conditions can result in transient CO situations Excessive...

Страница 24: ...ntation Everyone is susceptible but experts agree that unborn babies pregnant women senior citizens and people with heart or respiratory problems are especially vulnerable If symptoms of carbon monoxi...

Страница 25: ...hile the second person stays to account for additional family members Establish a rule that once you re out you never reenter under any circumstance Current studies have shown smoke alarms may not awa...

Страница 26: ...ion for those areas separated by a door from the areas protected by the required smoke alarms For this reason it is recommended that the householder consider the use of additional smoke alarms for tho...

Страница 27: ...CC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and...

Страница 28: ...are limited in duration to the above warranty period In no event shall the Manufacturer be liable for loss of use of this product or for any indirect special incidental or consequential damages or cos...

Страница 29: ...302 USA Please include your name address and phone number along with a brief description of what is wrong with the unit For further assistance please call our toll free Product Support Line at 1 800 8...

Страница 30: ...Product Support Line at 1 800 880 6788 or contact us at our website at www kidde com Kidde 1016 Corporate Park Drive Mebane NC 27302 Custom Assembled in China with U S and Foreign Components 2553 720...