EN: Installation Sheet 

Mounting the unit 

During installation, protect the electronics against water, as 
trapped moisture can affect or damage the unit. 

Note: 

When locating the detector, please ensure the detector’s 

field of view is unobstructed. 

To mount the detector: 

1.  Drill the wall to accept the fixing screws using the drilling 

template provided. Leave a minimum of 10 cm clearance 
above the top of the detector housing to allow the cover 
and the detector to be positioned correctly. 

2.  Remove the back wall fixing plate. Screw the back plate to 

the wall. Always ensure that one of the fixing screws is 
used to secure the rear tamper plate to the wall (Figure 1, 
item 1) as well as using the other screw fixing points 
(Figure 1, item 2). Fit the detector main body to the back 
plate. 

3.  Remove the 2 battery compartment screws and remove 

the battery compartment cover (Figure 2). 

4.  Fit the two batteries provided. Please observe the correct 

polarity (Figure 3). Replace the battery compartment cover 
and secure the 2 fixing screws (Figure 2). 

5.  Remove the detector cover assembly by loosening the 

front locking screw. Use the opening tool as shown in 
Figure 4 to carefully lever the front cover away from the 
detector base. The cover hinges from the top and lifts out 
of the location slot (Figure 5). 

6.  Fit the detector main body to the back plate. 

7.  When the detector is aligned and connected, fit the cover 

to the detector main body and tighten the locking screw. 

Batteries 

WARNING: 

Risk of explosion if the battery is replaced by an 

incorrect type. 

Only use CR123 3 V lithium batteries (2 x provided). This 
ensures 3 years operation under normal conditions. 

To extend battery life, a 3rd battery can be fitted into the spare 
position within the battery holder (Figure 3). 

To preserve battery life the detector has a 2-minute sleep timer 
after detection. This is reduced to 5 seconds during walk test. 

Multibeam alignment and masking 

The detector module is fitted with two sliding shutters to reduce 
the detection angle. 

The curtains are fitted to the pan and tilt module as shown in 
Figure 7. Each section of the detector lens gives a coverage 
pattern of approximately 14 degrees. 

When coverage exceeds the desired detection area, adjust the 
module as required and mask off any beams, either vertically 
or horizontally, to avoid unwanted detection. 

Use portions of the self-adhesive silver mask applied to the 
rear, smooth side of the lens. As an example for pet alley 
masking refer to Figure 8. To replace the lens, begin by sliding 
one side of the lens into the clips on the pan and tilt module. 
After one side is secure, do the same for the opposite side 
ensuring the lens is the correct orientation with the smooth side 
facing in and the two rows of circles to the bottom. 

Always replace the lens the correct way up to ensure exact 
beam pattern coverage as shown in Figure 8. 

Table 1 below summarizes typical alignment and masking 
configurations. 

Table 1: Be

am alignment & masking configuration 

Configuration 

Height (m) 

Tilt (°) 

Max. range (m) 

Multibeam, 
optimum  

3  

5  

15  

Pet immunity [1]   1.5  

−2  

15  

[1] Black area should be masked for pet alley applications up to 15 
meters. 

Figure 9 shows the pattern for the maximum range in the 
optimum position and the top view of the beam pattern. 

Selectable options 

Figure 6, item 1 shows the Pulse Count selection jumper 
positions. 

Pulse count 

Pulse count is the number of times the detector must detect a 
presence before signalling an alarm. Pulse count 1 is the most 
sensitive. 