background image

 

2 / 11 

 

P/N 466-

2285 • REV E • ISS 18MAR19 

EN: Installation instructions 

 

Figure 1. Removing the sensor cover. 

Cover. 

Slot. 

Cover screw mounting hole. 

Figure 2. Battery insertion. 

+ end of battery. 

Figure 3. Mounting holes. 

Mounting hole for T screw. 

Mounting hole for L screw. 

Figure 4. Sensor and magnet alignment. 

Alignment marks. 

Figure 5. External contact wiring. 

Door/Window Sensor. 

4.7 Kohm. 

10 

EOL 4.7 Kohm. 

11 

Contacts. 

Figure 6. Input selection jumper. 

12 

Reed 1. 

13 

Reed 2. 

14 

Input selection jumper. 

15 

Reed 1 = Top two pins covered. 

16 

Reed 2 = Bottom two pins covered. 

17 

External contact = Jumper removed. 

 

Introduction

 

This is the 

433 Door/Window Sensor. 

You can install the 

sensor on doors, windows, and other objects that open and 
close. The sensor transmits signals to the control panel when a 
magnet mounted near the sensor is moved away from or 
closer to the sensor. The sensor is equipped with a wall and 
cover tamper for additional security.  

Installation guidelines

 

Use the following installation guidelines: 

• 

Mount the sensor on the door frame and the magnet on 
the door. If the sensor is used on double doors, mount the 
sensor on the least-used door and the magnet on the 
most-used door. 

• 

If possible, locate sensors within 30 m (100 ft.) of the 
panel. While a transmitter may have a range of 150 m 
(500 ft.) or more out in the open, the environment at the 
installation site can have a significant effect on transmitter 
range. Sometimes a change in sensor location can help 
overcome adverse wireless conditions. 

• 

Make sure the alignment arrow on the magnet points to 
the alignment mark on the sensor. 

• 

Place sensors at least 12 cm (4.7 in.) above the floor to 
avoid damaging them. 

• 

Avoid mounting sensors in areas where they will be 
exposed to moisture or where the sensor operating 
temperature range of 0 to 49°C (0 to 120°F) will be 
exceeded. 

• 

If possible, mount directly to a stud. If a stud is not 
available, use plastic anchors. 

• 

Avoid mounting the sensor in areas with a large quantity of 
metal or electrical wiring.  

• 

Only one input can be used at any given time. 

• 

End-of-line (EOL) resistors must always be connected to 
the external contact terminals. The sensor is shipped with 
a single EOL resistor already installed. The single resistor 
must be removed if the external contact is going to be 
used. See External contact wiring on page 2 for proper 
wiring details. 

• 

Mount sensors with screws, not double-sided tape. 

Materials needed

 

You will need the following tools and materials: 

• 

Two 

6 x 1.00 in. PPH (Phillips pan head) screws and two 

plastic anchors for mounting the sensor (included). 

• 

Two 

6 x 0.625 in. PPH screws for mounting the magnet 

(included). 

• 

One 

4 x 0.250 in. PPH screw to secure the sensor cover 

to the sensor base (included). 

• 

External contact end-of-line (EOL) resistors (included). 

• 

Phillips screwdriver. 

Caution: 

You must be free of all static electricity when 

handling electronic components. Touch a grounded, bare 
metal surface before touching a circuit board or wear a 
grounded wrist strap. 

Programming

 

The following steps describe general guidelines for 
programming (learning) the sensor into panel memory. Refer to 
the specific panel/and or receiver’s documentation for 
complete programming details. 

1.  To remove the sensor cover, press a small screwdriver 

into the slot on the end of the sensor while lifting the cover 
(see fig. 1). 

2.  If required, insert the battery into the battery holder, 

observing correct polarity (see fig. 2). 

3.  Set the panel to program mode. 

4.  Proceed to the 

Learn sensors

 menu. 

5.  Press and release the tamper switch on the sensor until 

the panel responds. 

6.  Select the appropriate sensor group and sensor number. 

7.  Exit program mode. 

Verify RF communication

 

Before mounting the sensor, verify that the sensor mounting 
location provides good RF communications to the panel. 

To verify, do the following: 

1.  Put the panel/receiver into sensor test mode. 

2.  Take the sensor to the mounting location. 

Содержание Interlogix NX-451-N

Страница 1: ...UTC Fire Security Americas Corporation Inc 1 of 11 P N 466 2285 REV E ISS 18MAR19 433 Door Window Sensor Installation Sheet EN DE FR IT 1 2 3 4 5 6 1cm 0 4 1cm 0 4 1 2 3 4 5 6 7 8 9 10 11 12 13 15 16...

Страница 2: ...ount directly to a stud If a stud is not available use plastic anchors Avoid mounting the sensor in areas with a large quantity of metal or electrical wiring Only one input can be used at any given ti...

Страница 3: ...e door window input can be used at any given time For example if the external contact is being used neither of the internal reed switches can be used Position the input selection jumper to select inte...

Страница 4: ...tagebohrung f r T Schraube 6 Montagebohrung f r L Schraube Abbildung 4 Ausrichtung von Melder und Magnet 7 Ausrichtungsmarkierungen Abbildung 5 Beschaltung des externen Kontakts 8 T r Fensterkontakt 9...

Страница 5: ...anheben Siehe Abb 1 2 So erforderlich setzen Sie die Batterie in den Halter Achten Sie auf die richtige Polarit t siehe Abb 2 3 Versetzen Sie die Zentrale in den Programmiermodus 4 F hren Sie das Mel...

Страница 6: ...I4B N 600 1056 43 Wei NX 450 N RF320I4 N 600 1057 43 Frequenz 433 050 MHz 434 040 MHz Kompatibilit t Interlogix 433MHz AM Zentralen Empf nger Batterietyp 3 0 V 1300mAh Lithium Empfohlene Batterien Dur...

Страница 7: ...tecteur et ceux de l aimant Placer les d tecteurs au moins 12 cm du sol pour viter de les endommager Eviter de monter les d tecteurs dans des endroits humides ou bien dans des plages de temp ratures n...

Страница 8: ...e RFL une en s rie avec le contact une autre en parall le avec celui ci Cela permet d obtenir la supervision de l tat normalement ferm comme suit Circuit Ouvert Court circuit Autoprotection 1 R sistan...

Страница 9: ...consultez notre site Web www utcfireandsecurity com IT Istruzioni di Installazione Figura 1 Rimozione del coperchio del sensore 1 Coperchio 2 Fessura 3 Foro vite di fissaggio Coperchio Figura 2 Batter...

Страница 10: ...Uscire dal menu di programmazione Verificare la comunicazione via radio RF Prima di installare il sensore verificare che la posizione in cui verr installato fornisca una buona comunicazione via radio...

Страница 11: ...CR123A Durata batteria stimato Da 3 a 5 anni a 20 C Intervallo di Supervisione Minore di 20 minuti Potenza RF in uscita max 0 50 dBm Temperatura di Funzionamento Da 0 a 49 C da 0 a 120 F Temperatura...

Отзывы: