-7-

CHIMNEY CONNECTOR (STOVE PIPE)

The chimney connector and chimney must have the same diameter 

as the stove outlet (6”). If this is not the case, we recommend you 

contact your dealer to ensure there will be no problem with the 

draft. The stovepipe must be made of aluminized or cold roll steel 

and  have  a  minimum  thickness  of  0.021”  or  0.53mm.  It  is  strictly 

forbidden to use galvanized steel. The smoke pipe should be 

assembled to promote the male section (crimped end) of the 

pipe to be faced down. Attach each section to another with three 

equidistant metal screws. The pipe must be short and straight. 

All sections installed horizontally must slope at least 1/4 inch per 

foot, with the upper end of the section toward the chimney. Any 

installation with a horizontal run of chimney pipe must conform 

to NFPA 211. Contact NFPA (National Fire Protection Association) and request the latest edition of the NFPA 

Standard 211. To ensure a good draft, the total length of the coupling pipe should never exceed 8’ to 10’ (2.4m to 

3.04m). Except for cases of vertical installation, in a cathedral-roof style where the smoke exhaust system can be 

much longer and connected without problem to the chimney at the ceiling of the room. There should never be 

more than two 90 degrees elbows in the smoke exhaust system. The installation of a “barometric draft stabilizer” 

(fireplace register) on a smoke exhaust system is prohibited. Furthermore, the installation of a draft damper is not 

recommended. With a controlled combustion wood stove, the draft is regulated upon intake of the combustion 

air in the stove and not at the exhaust.

IMPORTANCE OF PROPER DRAFT

Draft is a force that moves air from the appliance up through the chimney. The amount of draft in your chimney 

depends on the length of the chimney, local geography, nearby obstructions and other factors. Too much draft 

may  cause  excessive  temperatures  in  the  appliance.  An  inadequate  draft  may  cause  back-puffing  into  the 

room and “plugging” of the chimney. An inadequate draft will cause the appliance to leak smoke into the room 

through appliance and chimney connector joints. An uncontrollable burn or excessive temperature indicates an 

excessive draft.

CHIMNEY

Your wood stove may be hooked up with a 6” factory-

built or masonry chimney. If you are using a factory-

built chimney, it must comply with UL 103 or CSA-B365 

standard;  therefore  it  must  be  a  Type  HT  (2100°F).  It 

must be installed according to the manufacturer’s 

specifications.  Take  into  account  the  chimney’s 

location to ensure it is not too close to neighbors or 

in a valley which may cause unhealthy or nuisance 

conditions.  If  you  are  using  a  masonry  chimney,  it 

must be built in compliance with the specifications of 

the National Building Code. It must be lined with fire 

clay bricks, metal or clay tiles sealed together with fire 

cement. Round flues are the most efficient. The interior diameter of the chimney flue must be identical to the 

stove smoke exhaust. A flue which is too small may cause draft problems, while a large flue favors rapid cooling 

of the gas, and hence the build-up of creosote and the risk of chimney fires. Note that it is the chimney and not 

the stove which creates the draft effect; your stove’s performance is directly dependent on an adequate draft 

from your chimney. 

Do not connect this unit to a chimney flue serving another appliance.

The following recommendations may be useful for the installation of your chimney:

1. 

It must rise above the roof at least 3’ (0.9m) from the uppermost point of contact.

2. 

The chimney must exceed any part of the building or other obstruction within a 10’ (3.04m) distance by a 

height of 2’ (0.6m).

3.  The  installation  of  an  interior  chimney  is  always  preferable  to  an  exterior  chimney.    Indeed,  the  interior 

chimney will, by definition, be hotter than an exterior chimney, being heated up by the ambient air in the 

house. Therefore the gas which circulates will cool more slowly, thus reducing the build-up of creosote and 

the risk of chimney fires.

4. 

The draft caused by the tendency for hot air to rise will be increased with an interior chimney.

5. 

Using a fire screen at the extremity of the chimney requires regular inspection to ensure that it is not obstructed 

thus blocking the draft, and it should be cleaned when used regularly.

To

Appliance

Содержание VOGELZANG TR007E

Страница 1: ...ne lesquels sont reconnus dans l tat de la Californie comme causant le cancer et des malformations cong nitales ou autres dommages au f tus Pour obtenir plus de renseignements veuillez consulter le si...

Страница 2: ...with your records for any claims Combustible Wood Colors Metallic Black Flue Pipe Diameter 6 153 mm Flue Pipe Type Standard Single Wall or Double Wall Black or Blued Steel 2100 F 650 C Minimum Chimney...

Страница 3: ...Attach two corner pieces A to the center section B of skirting and secure with four 4 truss head screws 2 Attach the side skirting sections C D to the corner pieces and secure with four 4 truss head s...

Страница 4: ...IN THIS HEATER KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE HEATER WHILE IT IS IN USE IN THE EVENT OF A CHIMNEY FIRE PUSH THE AIR CONTROL FULL CLOSED TO DEPRIVE THE FIRE OF OXYGEN CALL THE FIRE DEPARTMENT...

Страница 5: ...le home with 8 GA copper wire using a serrated or star washer to penetrate paint or protective coating to ensure grounding When moving your mobile home all exterior venting must be removed while the m...

Страница 6: ...heating and cooling contractor or certified wood stove installer Drill a 5 hole through the wall at the desired point of entry The point of entry should be at or below the level of the intake air tube...

Страница 7: ...o the room through appliance and chimney connector joints An uncontrollable burn or excessive temperature indicates an excessive draft CHIMNEY Your wood stove may be hooked up with a 6 factory built o...

Страница 8: ...as recommended by the manufacturer The chimney must be the required height above the roof or other obstructions for safety and proper draft operation MASONRY CHIMNEY Ensure that a masonry chimney meet...

Страница 9: ...h has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm separation area containing fiberglass insulation from the outer surface of the wall thimble t...

Страница 10: ...ns Under extreme conditions it may rot instead of drying This point cannot be over stressed the vast majority of the problems related to the operation of a wood stove is caused by the fact that the wo...

Страница 11: ...heater is designed to burn natural wood only Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods as compared to softwoods or to green or freshly cut har...

Страница 12: ...the best heating burn rates after a good fire is established a lower burn rate may be a better option for efficient heating A lower burn rate slows the flow of usable heat out of the home through the...

Страница 13: ...minute point of loading your fuel the primary air slide should be set at the medium setting which is about 1 2 inch open from the fully closed position For a low burn setting once the high burn or med...

Страница 14: ...ed and air blown clean Make sure the blades do not have build up CAUTION Do not overfire appliance You are overfiring if any part of the appliance glows red Close the door and shut damper immediately...

Страница 15: ...ly Do not abuse the glass door by striking or slamming shut Do not use the stove if the glass is broken If the glass on your stove breaks replace only with the glass supplied from your heater dealer N...

Страница 16: ...E MENT WIRING MUST HAVE EQUIVALENT INSULA TION AND TEMPERATURE RATING 105 C CAUTION MOVING PARTS CAN CAUSE INJURY DO NOT OPERATEWITH COVER REMOVED DANGER SHOCKHAZARD DISCONNECT POWERSOURCEBEFOREINSTAL...

Страница 17: ...2279 Hearth Trim 1 7 69912 Ash Drawer 1 8 26548 Ash Drawer Support 1 9 26541 Left Side Skirt 1 10 40597 Skirt Corner 2 11 26546 Front Skirt 1 12 26553 Right Side Skirt 1 13 69911 Pedestal 1 IN ORDER T...

Страница 18: ...9 20 5 892281 1 5 Firebrick 2 6 40595 Half Brick Ash Plug 1 7 86698 Tube 1 Secondary Air Tube 4mm 1 8 86699 Tube 2 3 Secondary Air Tube 3mm 2 9 86700 Tube 4 Secondary Air Tube 2 5mm 1 10 86701 Tube 5...

Страница 19: ...19 Notes...

Страница 20: ...07 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _______________...

Страница 21: ...orsque vous nous crivez donnez toujours le num ro de mod le complet qui se trouve sur la plaque signal tique fix e sur l appareil de chauffage Lors de commandes de pi ces d tach es donnez toujours les...

Страница 22: ...____________________________ Service de 07 Date _____________________ Nom de l ing nieur ____________________________ N de licence _________________________________ Compagnie _________________________...

Страница 23: ...brique r fractaire 2 6 40595 Bouchon de cendre demi brique 1 7 86698 tube d air secondaire 1 4mm 1 8 86699 tube d air secondaire 2 3 3mm 2 9 86700 tube d air secondaire 4 2 5mm 1 10 86701 tube d air...

Страница 24: ...p rieure 1 6 892279 Garniture de foyer 1 7 69912 Tiroir cendres 1 8 26548 Support de tiroir cendres 1 9 26541 Jupe c t gauche 1 10 40597 Coin de jupe 2 11 26546 Jupe avant 1 12 26553 Jupe c t droit 1...

Страница 25: ...ctrique entrer en contact avec une surface chaude Garder le fil lectrique 12po 30cm au moins de la surface du po le ou des conduits ATTENTION PI ces mobiles pouvant causer des blessures Ne pas faire f...

Страница 26: ...ait rayer Utilisez un produit sp cialis disponible dans les magasins o les po les bois sont vendus Le verre ne doit tre lav qu froid ATTENTION LES CENDRES POURRAIENT CONTENIR DES EMBRES CHAUDES M ME A...

Страница 27: ...ustion lente Par cons quent des r sidus de cr osote s accumulent sur le rev tement du conduit de fum e Lorsqu elle est allum e cette cr osote fait un feu extr mement lev Le raccord de chemin e et la c...

Страница 28: ...E Pour un fonctionnement optimal de cet appareil il est recommand de le faire fonctionner avec une charge de bois approximativement quivalente la hauteur des briques r fractaires Il est important de n...

Страница 29: ...20 minutes A rez de fa on suffi sante pour liminer la fum e ou les odeurs caus es par ces feux ATTENTION ne laissez pas l appareil sans surveillance avec la porte ouverte Remarque utilisez uniquement...

Страница 30: ...e sciure impr gn e de cire ou de b ches avec des additifs chimiques Les b ches fabriqu es partir de sciure de bois compress e 100 peuvent tre br l es mais faites attention br ler trop de ces b ches en...

Страница 31: ...m me pourrir au lieu de s cher On ne saurait trop soulign que la vaste majorit des probl mes li s au fonctionnement d un insert bois est caus e par le fait que le bois utilis tait trop humide ou avai...

Страница 32: ...bustible Commencez avec une partie de chemin e Solid Pak fabriqu e en usine agr e d au moins 12 po 304 mm de diam tre int rieur avec une isolation de 1 po 25 4 mm ou plus et un raccord de chemin e de...

Страница 33: ...gagement de 2 po Chapeau homologu Mur combustible Consulter D gagement des combustibles Protecteur de plancher Conduit de raccordement de chemin e Solive de toit combustible Chemin e homologu Mitre So...

Страница 34: ...mp rature excessive indique un tirage excessif Pente de po par pied Partie m le vers le bas 3 vis Vers l appareil Installer l extr mit sertie vers le po le Direction de la circulation des gaz de condu...

Страница 35: ...nt agr ou d un installateur de po le bois certifi Percez un trou de 5 pouces travers le mur au point d entr e souhait Le point d entr e doit tre au niveau ou en dessous du niveau du tuyau d air d admi...

Страница 36: ...lations de maisons mobiles doivent r pondre aux exigences suivantes Le chauffe eau doit tre connect une chemin e pr fabriqu e conforme la norme CAN ULC S629 norme pour les chemin es pr fabriqu es 650...

Страница 37: ...icile Le po le doit par cons quent tre install dans la pi ce o vous passez le plus de temps et dans la pi ce la plus spacieuse possible Rappelez vous que les po les bois produisent une chaleur rayonna...

Страница 38: ...base du socle Fixez deux pi ces d angle A la section centrale B de la plinthe et fixez les avec quatre 4 vis t te bomb e 2 Fixez les plinthes lat rales C et D aux pi ces d angle et fixez les avec qua...

Страница 39: ...cier noir ou bronz 2100 F 650 C Hauteur minimale de la chemin e 12 pi 3 7 m Longueur maximale des b ches 18 po 458 mm lectrique 120VAC 0 55A 60Hz Dimensions Profondeur Largeur Hauteur G n rales Profon...

Страница 40: ...nnus dans l tat de la Californie comme causant le cancer et des malformations cong nitales ou autres dommages au f tus Pour obtenir plus de renseignements veuillez consulter le site www P65warnings ca...

Отзывы: