Stove Feeds Pellets, But Will Not Ignite
Possible Causes

Possible Remedies: (Unplug stove first when possible)

Air damper open too far for ignition.

In some situations it may be necessary to have the damper 

completely closed for ignition to take place. After there is a flame, 

the damper can then be adjusted for the desired feed setting.

Blockage in igniter tube or inlet for igniter tube.

Find the igniter housing on the backside of the firewall. The air 

intake hole is a small hole located on bottom side of the housing. 

Make sure it is clear. Also, look from the front of the stove to make 

sure there is not any debris around the igniter element inside of 

the igniter housing.

The burnpot is not pushed completely to the rear 

of the firebox.

Make sure that the air intake collar on the burnpot is touching the 

rear wall of the firebox.

Bad igniter element.

Put power directly to the igniter element. Watch the tip of the 

igniter from the front of the stove. After about 2 minutes the tip 

should glow. If it does not, the element is bad.

The control board is not sending power to the 

igniter.

Check the voltage going to the igniter during startup. It should be 

a full current. If the voltage is lower than full current, check the 

wiring. If the wiring checks out good, the board is bad.

Smoke Smell Coming Back Into The Home
Possible Causes

Possible Remedies: (Unplug stove first when possible)

There is a leak in the vent pipe system.

Inspect all vent pipe connections. Make sure they are sealed with 

RTV silicone that has a temperature rating on 500 degree F or 

higher. Also, seal joints with UL-181-AP foil tape. Also, make sure 

the square to round adapter piece on the combustion blower has 

been properly sealed with the same RTV.

The gasket on the combustion blower has gone 

bad.

Inspect both gaskets on the combustion blower to make sure 

they are in good shape.

Because it is a wood-burning device, your pellet heater may emit a faint wood-burning odor. If this increases beyond 

normal, or if you notice an unusual soot build-up on walls or furniture, check your exhaust system carefully for leaks. 

All joints should be properly sealed. Also clean your stove, following instructions in “MAINTENANCE”. If problem 

persists, contact customer service.

Convection Blower Shuts Off And Comes Back On
Possible Causes

Possible Remedies: (Unplug stove first when possible)

The convection blower is overheating and 

tripping the internal temperature shutoff.

Clean any dust off of the windings and fan blades. If cleaning the 

blower does not help, the blower may be bad.

Circuit board malfunction.

Test the current going to the convection blower. If there is power 

being sent to the blower when it is shut off, then the control 

board is fine. If there is NOT power being sent to the blower when 

it shuts off during operation, then you have a bad control board.

TROUBLESHOOTING GUIDE

Содержание US5517-P

Страница 1: ...g or fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use y...

Страница 2: ...ater meets the 2020 U S Environmental Protection Agency s crib wood emission limits for wood heaters sold after May 15 2020 Under specific EPA test conditions this heater has been shown to deliver hea...

Страница 3: ...and_____________________________________________ If no Date of inspection of existing venting system ________________________________________________________________ COMMISSIONING Confirm Hearth Pad I...

Страница 4: ...MUST BE PLUGGED INTO A 110 120V 60 HZ GROUNDED ELECTRICAL OUTLET DO NOT USE AN ADAPTER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONT OF OR OVER THE HEATER DO N...

Страница 5: ...or non combustible surface should be large enough to cover at least the area under the product and 6 153 mm beyond the front and beyond each side of the fuel loading and ash removal openings Floor pro...

Страница 6: ...ate paint or protective coating to ensure grounding Vent must be 3 or 4 inch PL Vent and must extend a minimum or 36 914 mm above the roof line of the mobile home and must be installed using a certifi...

Страница 7: ...pellet vent pipe is not furnished with the unit and must be purchased separately PELLET VENT INSTALLATION The installation must include a clean out tee to enable collection of fly ash and to permit pe...

Страница 8: ...d void your warranty HORIZONTAL EXHAUST VENT INSTALLATION 1 Locate your pellet stove in a location which meets the requirements of this manual but in an area where it does not interfere with the house...

Страница 9: ...o get above the snowdrift line This same installation can be used if your heater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is reached Wit...

Страница 10: ...d and or inspected by a qualified chimney sweep before proceeding with the installation of your pellet stove 2 To the right is an example of an installation using part number 860001 3 6 transition int...

Страница 11: ...at range 5 C C F Button The C F button changes the two digit display from degrees Celsius to degrees Fahrenheit D MODE M T BUTTON The Mode of the stove can be switched between manual and controlled wi...

Страница 12: ...nes Binders Some pellets are produced with materials to hold the together or bind them High ash content Poor quality pellets will often create smoke and dirty glass They will create a need for more fr...

Страница 13: ...CES AND A SAFETY CONCERN MAY ARISE FROM SPARKS OR FUMES ENTERING THE ROOM THE DOOR MUST BE CLOSED AND SEALED DURING OPERATION If the door is opened while the stove is in operation it must be closed wi...

Страница 14: ...nge to activatetheairswitch shuttingthefuelfeedoff Thestove will shut down and show E2 on the two digit display The stove has to fully shut down before restarting INTERIOR CHAMBERS Burn Pot Periodical...

Страница 15: ...of chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professionally inspected cleaned and if necessary repai...

Страница 16: ...glass from the door frame 4 Replace the glass and gasket making sure the gasket runs the full perimeter of the glass edge 5 Re install the retainer and eight nuts and rope gasket using high temperatu...

Страница 17: ...ion of this manual Close the slide about 1 4 after your stove cools down Restart your stove If your display shows E1 again close the slide another 1 4 and restart The convection blower is overheating...

Страница 18: ...ombustion blower failure With the stove on check to see if the combustion blower is running If it is not you will need to check for power going to the combustion blower It should be a full current If...

Страница 19: ...move the two bolts that hold the auger bracket to the auger tube The auger bracket will now be able to be removed form the auger tube Remove the two bolts on the side of the auger tube to remove the l...

Страница 20: ...pper is open When operating the unit be sure the hopper lid is closed so that the hopper safety switch will activate Check the wires leading from the hopper safety switch to the control panel and auge...

Страница 21: ...The Home Possible Causes Possible Remedies Unplug stove first when possible There is a leak in the vent pipe system Inspect all vent pipe connections Make sure they are sealed with RTV silicone that...

Страница 22: ...NOTE NUMBERS 4 6 16 ARE NOT YET SHOWN Key Part Description Qty 1 88174 1 8 X 1 Window Gasket W Adhesive 7 28 ft 2 893159 Clear Glass 1 3 88324 1 Rope Gasket 5 17 ft 4 80780 IR Remote 1 5 893629 Burnpo...

Страница 23: ...ordered Before contacting customer service write down the model number and the serial number of this unit That information can be found on the certification label attached to the back of the unit Oth...

Страница 24: ..._____ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No ________________________...

Страница 25: ...2022 United States Stove Company 25 NOTES...

Страница 26: ...26 2022 United States Stove Company NOTES...

Страница 27: ...2022 United States Stove Company 27 NOTES...

Страница 28: ...____________________ Service de 07 Date ______________________ Nom de l ing nieur _________________________________ N de licence ______________________________________ Compagnie ______________________...

Страница 29: ...areil Lors de la commande de pi ces de rechange les informations contenues dans ce manuel vous aideront vous assurer que les bons articles sont command s Avant de contacter le service client notez le...

Страница 30: ...sif 7 28 pi 2 893159 Verre propre 1 3 88324 Joint de corde 1 po 5 17 pi 4 80780 T l commande IR 1 5 69762 Assemblage du pot de combustion 1 6 80491 Micro interrupteur 1 7 80518 Assemblage du clavier 1...

Страница 31: ...nt deux fois par seconde Cela indique que le po le fonctionne normalement et qu une condition de temp rature excessive existe provoquant l arr t du combustible Indicateur de r glage du niveau de chale...

Страница 32: ...st me vis sans fin est bloqu ou il y a une vo te de combustible dans la tr mie qui emp che le combustible de s couler dans le syst me d approvisionnement vis sans fin PROBL ME CAUSE L allumeur automat...

Страница 33: ...propri taire sont sp cifiques votre appareil Lors de la commande de pi ces de rechange les informations contenues dans ce manuel vous aideront vous assurer que les bons articles sont command s Avant...

Страница 34: ...verre N UTILISEZ PAS de nettoyants abrasifs N effectuez PAS le nettoyage lorsque la vitre est CHAUDE N essayez pas de faire fonctionner l appareil avec du verre bris Le verre de remplacement peut tre...

Страница 35: ...p cialement con ue pour le type de chemin e utilis Un ramoneur qualifi peut fournir ce service Il est galement conseill d inspecter de nettoyer et si n cessaire de r parer la totalit du syst me avant...

Страница 36: ...ent le pot de combustion et la zone l int rieur du bo tier du pot de combustion En particulier il est conseill de nettoyer les trous du pot de combustion pour liminer toute accumulation qui pourrait e...

Страница 37: ...S CIRCONSTANCES ET UN PROBL ME DE S CURIT PEUT PROVOQUER DES TINCELLES OU DES FUM ES ENTRANT DANS LA PI CE LA PORTE DOIT TRE FERM E ET SCELL E PENDANT LE FONCTIONNEMENT Si la porte est ouverte pendant...

Страница 38: ...sont mouill s r duiront les performances Rangez vos pellets dans un endroit sec NE stockez PAS le carburant dans les d gagements d installation de l appareil ou dans l espace requis pour faire le ple...

Страница 39: ...faire en sorte que le po le se programme entre le r glage pr s lectionn de la plage de chaleur d sir e 1 5 et le r glage de la plage de chaleur minimale de 1 Le T Stat n allumera ni ne teindra le po...

Страница 40: ...pour r gler la vitesse du ventilateur Quand le syst me de chauffage est en mode manuel le thermostat en option ne contr lera pas correctement l unit Lorsque vous ajustez le r glage du ventilateur de t...

Страница 41: ...ent sur le diagramme en barres passant du niveau 1 au niveau 5 de chauffage C Touche C F La touche C F fait passer l affichage deux chiffres des degr s Celsius aux degr s Fahrenheit et vice versa D TO...

Страница 42: ...illustrations ci dessous ne sont que des exemples Veuillez confirmer tous les codes du b timent locaux ou ragulations ayant comp tence avant de demander un installateur qualifi de proc der cette insta...

Страница 43: ...L installation travers le mur est l installation la moins ch re et la plus simple Ne jamais mettre fin l vent de fin sous un pont dans une alc ve sous une fen tre ou entre deux fen tres 90 Elbow Cap d...

Страница 44: ...ure 4 Localisez le centre du tuyau d chappement de votre unit Ce point devrait ensuite tre tendu la paroi int rieure de votre maison Une fois que vous avez localis le point central sur la paroi int ri...

Страница 45: ...coude ou t r duit le potentiel de tirage de 30 50 Tous les joints du syst me de ventilation doivent tre fix s par au moins 3 vis et tous les joints doivent tre scell s avec du mastic silicone Hi Temp...

Страница 46: ...obligatoire pour l installation d une maison mobile Consultez la section Alimentation en air ext rieur et votre revendeur pour l achat V rifiez aupr s de vos responsables locaux du b timent car d aut...

Страница 47: ...des cendres La protection du plancher doit s tendre sous et 2 51 mm de chaque c t du t de chemin e pour une installation verticale int rieure Les installations canadiennes n cessitent un minimum de 18...

Страница 48: ...UPEZ PAS LA FICHE DE TERRE N ACHEMINEZ PAS LE CORDON LECTRIQUE SOUS DEVANT OU SUR LE PO LE NE FAITES PAS COURIR LE CORDON LECTRIQUE DANS LES ZONES DE PASSAGE ET NE LE COINCEZ PAS SOUS LES MEUBLES ATTE...

Страница 49: ...n date d inspection du syst me de ventilation existant ___________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment aux i...

Страница 50: ...bs hr Taille de Pellet peut effectuer le taux r el d alimentation en carburant et de br ler fois Taux d alimentation en carburant peut varier par autant que 20 Utiliser PFI carburant list pour de meil...

Страница 51: ...ictions et les exigences d installation dans votre r gion NE JAMAIS UTILISER CE PRODUIT SANS SURVEILLANCE MISE EN GARDE Veuillez lire l int gralit de ce manuel avant d installer ou d utiliser votre no...

Отзывы: