© 2021 United States Stove Company
15
knob clockwise for slower speeds and counter-clockwise
for faster speeds. To turn the blower off, turn the speed
control knob fully counter-clockwise. It is recommended
to turn the blower off when the unit is not in operation.
The blower needs to be removed and air-blown clean.
Make sure the blades do not have build up. Caution!
Route the Power Supply Cord away from the heat source
and out of high traffic areas.
CLEAN OUT MAINTENANCE
Burning unseasoned wet wood only hurts your stoves
efficiency and leads to accelerated creosote buildup in
your chimney. The clean outs are secured to the firebox
with two 5/16” screws. Remove the clean outs and
vacuum out any accumulated ash. This should be done at
least once per month or more frequently if large amounts
of ash are noticed while cleaning or if the stove does not
seem to be burning properly. The firing and ash doors
must be closed and sealed during operation.
Air Cleanout
OPERATION INSTRUCTIONS