background image

© 2021 United States Stove Company

15

CAUTION:

DO NOT OVERFIRE APPLIANCE. YOU ARE 

OVERFIRING IF ANY PART OF THE APPLIANCE 

GLOWS RED. CLOSE THE DOOR AND SHUT DAMPER 

IMMEDIATELY TO REDUCE THE AIR SUPPLY AND 

SLOW DOWN THE FIRE.

CAUTION:

SLOW BURNING FIRES FOR EXTENDED USE OR 

BURNING GREEN WOOD MAY CAUSE EXCESSIVE 

CREOSOTE BUILD-UP. IGNITION OF CREOSOTE 

OR OVERFIRING COULD CAUSE A CHIMNEY 

FIRE. CHIMNEY FIRES BURN EXTREMELY HOT 

AND MAY IGNITE SURROUNDING COMBUSTIBLE 

MATERIALS. IN CASE OF A CHIMNEY FIRE, CALL 

THE FIRE DEPARTMENT IMMEDIATELY! 

CREOSOTE FORMATION AND NEED FOR 

REMOVAL

When wood is burned slowly, it produces tar and other 

organic vapors, which combine with expelled moisture 

to form creosote. The creosote vapors condense in the 

relatively cool chimney flue of a slow-burning fire. As a 

result, creosote residue accumulates on the flue lining. 

When ignited this creosote makes an extremely high 

temper fire. The chimney connector and chimney should 

be inspected at least once every two months during the 

heating season to determine if a creosote build-up has 

occurred. If creosote has accumulated (3 mm or more), 

it should be removed to reduce the risk of a chimney fire.
We strongly recommend that you install a magnetic 

thermometer on your smoke exhaust pipe, approximately 

18” above the stove. This thermometer will indicate the 

temperature of your gas exhaust fumes within the smoke 

exhaust system. The ideal temperature for these gases 

is somewhere between 275°F and 500°F. Below these 

temperatures, the build-up of creosote is promoted. 

Above 500°F, heat is wasted since a too large quantity is 

lost into the atmosphere.

TO PREVENT CREOSOTE BUILD UP

•  Always burn dry wood. This allows clean burns and 

higher chimney temperatures, therefore less creosote 

deposit.

•  Leave the air control fully open for about 5 min. every 

time you reload the stove to bring it back to proper 

operating temperatures. The secondary combustion 

can only take place if the firebox is hot enough.

•  Always check for creosote deposit once every two 

months and have your chimney cleaned at least once 

a year.

•  If a chimney or creosote fire occurs, close all dampers 

immediately. Wait for the fire to go out and the heater 

to cool, then inspect the chimney for damage. If no 

damage results, perform a chimney cleaning to ensure 

no more creosote deposits is remaining in the chimney.

CAUTION:

A CHIMNEY FIRE MAY CAUSE IGNITION OF WALL 

STUDS OR RAFTERS WHICH WERE ASSUMED TO 

BE A SAFE DISTANCE AWAY FROM THE CHIMNEY. 

IF A CHIMNEY FIRE OCCURS, HAVE YOUR 

CHIMNEY INSPECTED BY A QUALIFIED EXPERT 

BEFORE USING AGAIN.

ASH REMOVAL & DISPOSAL

Whenever ashes get 3 to 4 inches deep in your firebox or 

ash pan, and when the fire has burned down and cooled, 

remove excess ashes. Leave an ash bed approximately 

1 inch deep on the firebox bottom to help maintain a 

hot charcoal bed. Ashes should be placed in a metal 

container with a tight-fitting lid. The closed container of 

ashes should be placed on a non-combustible floor or the 

ground, away from all combustible materials, pending 

final disposal. The ashes should be retained in the closed 

container until all cinders have thoroughly cooled.

CAUTIONS:

•  ASHES COULD CONTAIN HOT EMBERS EVEN 

AFTER TWO DAYS WITHOUT OPERATING THE 

STOVE.

•  THE ASH PAN CAN BECOME VERY HOT. WEAR 

GLOVES TO PREVENT INJURY.

•  NEVER BURN THE STOVE WITH THE ASH TRAP 

OPEN. THIS WOULD RESULT IN OVER FIRING 

THE STOVE. DAMAGE TO THE STOVE AND EVEN 

HOUSE FIRE MAY RESULT.

SMOKE & CO MONITORS

Burning wood naturally produces smoke and carbon 

monoxide(CO) emissions. CO is a poisonous gas when 

exposed to elevated concentrations for extended 

periods. While the modern combustion systems in 

heaters drastically reduce the amount of CO emitted 

out the chimney, exposure to the gases in closed or 

NEVER OPERATE THIS PRODUCT WHILE UNATTENDED

CHIMNEY MAINTENANCE

Содержание US2000E-P

Страница 1: ...nstallation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your new room heater Failure to follow instructions m...

Страница 2: ...EIGHT Overall Depth x Width x Height US2000E Leg 20 5 521 mm 29 4 747 mm 31 3 796 mm US2000E Pedestal 21 534 mm 27 686 mm 31 4 798 mm Combustion Chamber Width x Depth 22 3 4 X 11 78 578 mm X 300 mm Vo...

Страница 3: ..._________________________________________ If no Date of inspection of the existing chimney system ___________________________________________________________ COMMISSIONING Confirm Hearth Pad Installat...

Страница 4: ...ower assembly must be disconnected from the source of electrical supply before attempting the installation The blower assembly is intended for use only with a stove that is marked to indicate such use...

Страница 5: ...R SPACE HEATED SHALL BE PROVIDED WHEN REQUIRED US Stove highly recommends your stove be installed by a qualified NFI US or WETT Canada technician To find the nearest qualified installer go to https nf...

Страница 6: ...loor to ceiling height must be at least 7 2 13m in all cases Do not place any combustible material within 4 1 2m of the front of the unit The clearance between the flue pipe and a wall are valid only...

Страница 7: ...r the end of the aluminium flex hose FOR USE IN MOBILE HOMES U S ONLY WARNING DO NOT INSTALL IN SLEEPING ROOM CAUTION THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR WALL AND CEILING ROOF MUST BE MA...

Страница 8: ...t may cause back puffing into the room and plugging of the chimney An inadequate draft will cause the appliance to leak smoke into the room through appliance and chimney connector joints An uncontroll...

Страница 9: ...re that a masonry chimney meets the minimum standards of the National Fire Protection Association NFPA by having it inspected by a professional Make sure there are no cracks loose mortar or other sign...

Страница 10: ...opening with a 24 gage minimum sheet metal support Maintain the 6 152 4 mm space There should also be a support sized to fit and hold the metal chimney connector See that the supports are fastened sec...

Страница 11: ...well seasoned natural wood may be used in your stove but specific varieties have better energy yields than others Higher efficiencies and lower emissions generally result when burning air dried seaso...

Страница 12: ...split wood about five inches in diameter parallel to the door on the bed of red embers Keep the air control fully open and close the door If the wood ignites within 90 seconds from the time it was pl...

Страница 13: ...re airflow through the kindling On top of the kindling place approximately 4 lbs of small pieces of cordwood NOTE Use smaller pieces of wood during start up and a high burn rate to increase the stove...

Страница 14: ...perly and has a high wood moisture content will produce excess visible smoke and burn poorly AIR TUBES The air tubes assembled in this unit are designed to provide an accurate mix of secondary air to...

Страница 15: ...min every time you reload the stove to bring it back to proper operating temperatures The secondary combustion can only take place if the firebox is hot enough Always check for creosote deposit once...

Страница 16: ...ended that you change the door gasket which makes your stove door air tight once a year in order to ensure good control over the combustion maximum efficiency and security To change the door gasket si...

Страница 17: ...8042 Rope Gasket 1 4 1 3 25845 Air Deflector 1 4 891492 Blower Assembly B36 1 5 26060 Rear Shield 1 6 610926 Rear Ashpan US2000E BP 1 7 29068 Pedestal US2000E BP 1 8 29065 Pedestal Front US2000E BP 1...

Страница 18: ...lass 1 6 26314 Gasket Clamp 1 7 26311 Bottom Glass Clamp 2 8 26312 Side Glass Clamp 4 1 2 3 6 4 5 7 10 9 8 5 6 2 1 3 4 7 8 To order parts Call 1 800 750 2723 Ext 5051 or Email to parts usstove com Key...

Страница 19: ...______ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No _______________________...

Страница 20: ...20 2021 United States Stove Company NOTES...

Страница 21: ...2021 United States Stove Company 21 NOTES...

Страница 22: ...ice de 07 Date ______________________ Nom de l ing nieur _________________________________ N de licence ______________________________________ Compagnie ________________________________________ N de t...

Страница 23: ...etenue de brique droite 1 7 40561 Bouchon de cendre 1 8 24103A Brique r fractaire demi pierre ponce 4 1 2 x 4 1 2 2 9 891414A Demi brique r fractaire 2 10 89066A Brique r fractaire ponce 4 1 2 x 9 14...

Страница 24: ...042 Joint de corde 1 4 po 1 3 25845 D flecteur d air 1 4 891492 Ensemble ventilateur Bb36 1 5 26060 Bouclier arri re 1 6 610926 Cendrier arri re US2000E BP 1 7 29068 Pi destal US2000E BP 1 8 29065 Pi...

Страница 25: ...JAMAIS LE PO LE SANS JOINT OU AVEC UN CASS DES DOMMAGES AU PO LE OU L INCENDIE DE LA MAISON PEUVENT EN R SULTER La porte de cet appareil utilise un joint de corde de 3 4 po de diam tre Il est recomma...

Страница 26: ...lures propres et des temp ratures de chemin e plus lev es donc moins de d p t de cr osote Laissez le contr le d air compl tement ouvert pendant environ 5 min chaque fois que vous rechargez le po le p...

Страница 27: ...a mal CONDUITS D AIR Les conduits d air assembl s dans cette unit sont con us pour offrir un m lange pr cis d air secondaire et assurer une plus grande efficacit Tout dommage ou d t rioration de ces c...

Страница 28: ...REMARQUE Utilisez des morceaux de bois plus petits pendant le d marrage et un taux de combustion lev pour augmenter la temp rature du po le 4 lb Tirez compl tement la commande d air Allumez le journa...

Страница 29: ...peur s chappe aux extr mit s de la pi ce votre bois est tremp ou fra chement coup vert N utilisez pas ce bois dans votre po le De grandes quantit s de cr osote pourraient se d poser dans votre chemin...

Страница 30: ...des missions plus faibles r sultent g n ralement de la combustion de bois durs s ch s l air par rapport aux r sineux ou aux feuillus trop verts ou fra chement coup s Les ressources suivantes peuvent a...

Страница 31: ...ord de chemin e m tallique V rifiez que les supports soient fix s de fa on s re aux surfaces de la paroi sur tous les c t s Assurez vous que les l ments de fixation utilis s pour maintenir le raccord...

Страница 32: ...autres signes de d t rioration et de blocage Faites nettoyer la chemin e avant d installer et de faire fonctionner le po le Lors du raccordement du po le travers une paroi combustible vers une chemin...

Страница 33: ...ou une temp rature excessive indique un tirage excessif CHEMIN E R gle 2 10 3 Fa tage 3 pi min 2 pi min 10 pi Votre po le bois peut tre raccord une chemin e pr fabriqu e de 6 po ou en ma onnerie Si v...

Страница 34: ...ONS AUX U UNIQUEMENT ATTENTION NE PAS INSTALLER DANS LA CHAMBRE COUCHER MISE EN GARDE L INT GRIT STRUCTURELLE DU PLANCHER DU MUR ET DU PLAFOND DU TOIT DE LA MAISON MOBILE DOIT TRE MAINTENUE UTILISEZ U...

Страница 35: ...plafond doit tre d au moins 7 pi 2 13 m dans tous les cas Ne placez aucune mati re combustible moins de 4 pi 1 2 m de l avant de l unit Le d gagement entre le tuyau de carneau et un mur est valable un...

Страница 36: ...E Le po le est fix la palette d exp dition avec 2 boulons Un boulon est situ l avant et au centre de l unit sous le cendrier L autre boulon est situ l arri re et au centre derri re le cendrier arri re...

Страница 37: ...tilis uniquement avec un po le qui est marqu pour indiquer une telle utilisation Ne faites pas passer le cordon d alimentation proximit ou sur des surfaces chaudes Fixez l ensemble l arri re du po le...

Страница 38: ...ion du syst me de chemin e existant ____________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment aux instructions d inst...

Страница 39: ...US2000E jambe 20 5 po 521 mm 29 4 po 747 mm 31 3 po 796 mm US2000E pi destal 21 po 534 mm 27 po 686 mm 31 4 po 798 mm Chambre de combustion Largeur x Profondeur 22 3 4 po X 11 78 po 578 mm X 300 mm V...

Страница 40: ...r gion NE JAMAIS UTILISER CE PRODUIT SANS SURVEILLANCE MISE EN GARDE Veuillez lire l int gralit de ce manuel avant d installer ou d utiliser votre nouveau radiateur Le non respect des instructions pe...

Отзывы: