-2-
READ ALL INSTRUCTIONS CAREFULLY
1. The installation of this unit must comply with your
local building code rulings. Please observe the
clearances to combustibles (fig. 2).
2. Do not install this unit in a mobile home or trailer
(NO EXCEPTIONS).
3. Always connect this unit to a chimney and vent to
the outside. Never vent to another room or inside a
building.
4. WARNING: DO NOT CONNECT
this unit to an
aluminum Type B gas vent. This is not safe.
5. CAUTION: DO NOT INSTALL THE MIRACLE HEAT IN A
HORIZONTAL POSITION.
6. The paint used on your appliance may give off
smoke and/or odor during the first fires. This may
occur during the first dozen fires until the paint has
cured. This will end and not reoccur after paint has
cured. Persons with lung conditions or owners of
susceptible domestic pets (such as birds) should
take prudent precautions. Open windows and
doors as needed to clear smoke and odor.
7. Be sure that your chimney is safely constructed and
in good repair. Have the chimney inspected by
the fire department or a qualified inspector. Your
insurance company may be able to recommend
a qualified inspector.
8. Creosote or soot may build up in the chimney
connector and chimney and cause a house/
building fire. Inspect this unit, the chimney
connector, and chimney twice monthly during
the heating season and clean if necessary (see
Maintenance & Service Hints, page 5).
9. Do not install this accessory on a stove, heater,
or fireplace pipe that has poor draft or “smokes.”
The Miracle Heat unit will aggravate this condition.
Correct the draft situation BEFORE installing.
10. Do not use a Miracle Heat that has a smaller
diameter than the flue outlet on your stove, heater,
or fireplace.
11. Do not connect duct work to the appliance. Do
not restrict the air movement inside or through the
appliance.
12.
Do not install on a stove, heater, or fireplace with
an operating temperature of less than 350 degrees
Fahrenheit.
13.
Do not install the appliance closer than 12” to
any combustible object or material. Maintain all
clearance requirements of the heating appliance
(see the appliance’s owner’s manual.)
14. Use at least three (3) sheet metal screws at each
connection to secure the appliance to the flue
pipe.
15. While in operation, keep the soot remover scraper
knob pulled out at least 5 inches from the front of
the unit.
16. Do not touch this unit while it and the heating
appliance is in operation. The surfaces are hot and
can cause severe burns. Keep children, clothing,
and combustible materials away from the unit.
17. Do not allow the power cord to touch any hot
surfaces. Keep the power cord at least 12” away
from the flue pipe
18. Use only with a grounded electrical socket. Consult
a qualified licensed electrician to provide a properly
grounded socket. Do not modify the electrical plug
in any way. Dangerous or damaging conditions
could result. Do not plug into an electrical outlet
that is not grounded or that is operated by a wall
mounted on/off switch.
19. The Miracle Heat MUST be plugged into an
electrical outlet whenever the stove is in use. Failure
to do so will likely result in damage to the electrical
components of the appliance and could result in
shock or electrical fire
20. Keep the unit plugged in at all times. Do Not
operate the stove if the Miracle Heat is inoperative.
Doing so will damage the electrical components.
Safety Instructions
CAUTION: SHOCK HAZARD
• Always disconnect plug from electrical source
before ad justing or attempting repairs.
• Always disconnect plug by grasping plug body –
Do not pull on cord to disconnect from wall outlet.
• Use only with properly grounded outlet. Do not
alter plug.
NOTE: A PROFESSIONAL, LICENSED HEATING AND
COOLING CONTRACTOR SHOULD BE CONSULTED IF
YOU HAVE QUESTIONS REGARDING THE INSTALLATION.