background image

© 2022 United States Stove Company

15

WARNING:

•  DO NOT USE CHEMICALS OR FLUIDS TO START 

THE FIRE - NEVER USE GASOLINE, GASOLINE-

TYPE LANTERN FUEL, KEROSENE, CHARCOAL 

LIGHTER FLUID, OR SIMILAR LIQUIDS TO START 

OR “FRESHEN UP” A FIRE IN THIS STOVE. KEEP 

ALL SUCH LIQUIDS WELL AWAY FROM THE 

STOVE WHILE IT IS IN USE.

•  HOT WHILE IN OPERATION. KEEP CHILDREN, 

CLOTHING AND FURNITURE AWAY. CONTACT 

MAY CAUSE SKIN BURNS.

This heater is designed to burn only PFI Premium grade 

pellets. DO NOT BURN:
1.  Garbage;
2.  Lawn clippings or yard waste;
3.  Materials containing rubber, including tires;
4.  Materials containing plastic;
5.  Waste petroleum products, paints or paint thinners, 

or asphalt products;

6.  Materials containing asbestos;
7.  Construction or demolition debris;
8.  Railroad ties or pressure-treated wood;
9.  Manure or animal remains;
10.  Salt water driftwood or other previously salt water 

saturated materials;

11.  Unseasoned wood; or
12.  Paper products, cardboard, plywood, or particleboard. 

The prohibition against burning these materials does 

not prohibit the use of fire starters made from paper, 

cardboard, saw dust, wax and similar substances 

for the purpose of starting a fire in an affected wood 

heater.

Burning these materials may result in release of toxic 

fumes or render the heater ineffective and cause smoke.

PROPER FUEL

ATTENTION:

THIS APPLIANCE IS DESIGNED FOR THE USE OF 

PELLETIZED FUEL THAT MEET OR EXCEED THE 

STANDARD SET BY THE PELLET FUEL INSTITUTE 

(PFI).

Your pellet stove is designed to burn premium hardwood 

pellets that comply with the Pellet Fuels Institute (PFI) 

standard (minimum of 40 lbs density per cubic ft, 1/4” to 

5/16” diameter, length no greater than 1.5”, not less than 

8,200 BTU/lb, moisture under 8% by weight, ash under 

1% by weight, and salt under 300 parts per million). 

Pellets that are soft, contain excessive amounts of loose 

sawdust, have been, or are wet, will result in reduced 

performance. Store your pellets in a dry place. DO NOT 

store the fuel within the installation clearances of the 

unit or within the space required for refuelling and ash 

removal. Doing so could result in a house fire. Do not over 

fire or use volatile fuels or combustibles, doing so may 

cause a personal and property damage hazards.
THIS STOVE IS APPROVED FOR BURNING PELLETIZED 

WOOD FUEL ONLY ! Factory-approved pellets are those 

1/4” or 5/16” in diameter and not over 1” long. Longer or 

thicker pellets sometimes bridge the auger flights, which 

prevents proper pellet feed. Burning wood in forms other 

than pellets is not permitted. It will violate the building 

codes for which the stove has been approved and will 

void all warranties. The design incorporates automatic 

feed of the pellet fuel into the fire at a carefully prescribed 

rate. Any additional fuel introduced by hand will not 

increase heat output but may seriously impair the stoves 

performance by generating considerable smoke. Do 

not burn wet pellets. The stove’s performance depends 

heavily on the quality of your pellet fuel. Avoid pellet 

brands that display these characteristics:
•  Excess Fines – “Fines” is a term describing crushed 

pellets or loose material that looks like sawdust or sand. 

Pellets can be screened before being placed in hopper 

to remove most fines.

•  Binders – Some pellets are produced with materials to 

hold the together, or “bind” them.

•  High ash content – Poor quality pellets will often create 

smoke and dirty glass. They will create a need for more 

frequent maintenance. You will have to empty the burn 

pot plus vacuum the entire system more often. Poor 

quality pellets could damage the auger. We cannot 

accept responsibility for damage due to poor quality 

pellet.

CAUTION:

•  KEEP FOREIGN OBJECTS OUT OF THE HOPPER.
•  THE MOVING PARTS OF THIS STOVE ARE 

PROPELLED BY HIGH TORQUE ELECTRIC 

MOTORS. KEEP ALL BODY PARTS AWAY FROM 

THE AUGER WHILE THE STOVE IS PLUGGED 

INTO AN ELECTRICAL OUTLET. THESE MOVING 

PARTS MAY BEGIN TO MOVE AT ANY TIME 

WHILE THE STOVE IS PLUGGED IN.

OPERATION INSTRUCTIONS

Содержание KING KP5522

Страница 1: ...lding or fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or u...

Страница 2: ...et fuel this heater has been shown to deliver heat at a rate of 32 591 to 13 640 Btu hr This heater achieved a particulate emissions rate of 1 5 g hr when tested to method ASTM E 2779 EPA Method 28R a...

Страница 3: ...and_____________________________________________ If no Date of inspection of existing venting system ________________________________________________________________ COMMISSIONING Confirm Hearth Pad I...

Страница 4: ...ires out of the top of the stove There will be two wire harnesses as shown 2 Unpack the top mount controls and ensure that the wiring harness shown is attached securely 3 Connect the factory installed...

Страница 5: ...SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONT OF OR OVER THE HEATER DO NOT ROUTE THE CORD IN FOOT TRAFFIC AREAS OR PINCH THE CORD UNDER FURNITURE CAUTION BURNING FUEL C...

Страница 6: ...e of the chimney tee for an interior vertical installation A Floor Protector of 1 26 mm thick is recommended for this installation D B C B A A Rear through wall 1 25 mm B Side 6 152 mm C Front 6 152 m...

Страница 7: ...rate paint or protective coating to ensure grounding Vent must be 3 or 4 inch PL Vent and must extend a minimum or 36 914 mm above the roof line of the mobile home and must be installed using a certif...

Страница 8: ...pellet vent pipe is not furnished with the unit and must be purchased separately PELLET VENT INSTALLATION The installation must include a clean out tee to enable collection of fly ash and to permit pe...

Страница 9: ...nd void your warranty HORIZONTAL EXHAUST VENT INSTALLATION 1 Locate your pellet stove in a location which meets the requirements of this manual but in an area where it does not interfere with the hous...

Страница 10: ...o get above the snowdrift line This same installation can be used if your heater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is reached Wit...

Страница 11: ...s A 6 venting system You must have the existing chimney system cleaned and or inspected by a qualified chimney sweep before proceeding with the installation of your pellet stove 2 To the right is an e...

Страница 12: ...t range 5 C C F Button The C F button changes the two digit display from degrees Celsius to degrees Fahrenheit D MODE M T BUTTON The Mode of the stove can be switched between manual and controlled wit...

Страница 13: ...heater is in the manual mode the optional thermostat will not properly control the unit When adjusting the Draft Fan setting try only 1 setting above or below the heat setting It is better to leave t...

Страница 14: ...the stove cycle between the preselected desired heat range setting 1 to 5 and the minimum heat range setting of 1 The T Stat will not turn the stove on and off When the desired room temperature has be...

Страница 15: ...reduced performance Store your pellets in a dry place DO NOT store the fuel within the installation clearances of the unit or within the space required for refuelling and ash removal Doing so could re...

Страница 16: ...tove will have to fully shut down and turn off before you will be able to restart the stove IGNITOR 1 Fill hopper and clean burn pot 2 Press the On Off button Make sure the green light comes on 3 Adju...

Страница 17: ...rswitch shuttingthefuelfeedoff Thestove will shut down and show E2 on the two digit display The stove has to fully shut down before restarting INTERIOR CHAMBERS Burn Pot Periodically remove and clean...

Страница 18: ...rush specifically designed for the type of chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professionally...

Страница 19: ...gloves carefully remove any loose pieces of glass from the door frame 4 Replace the glass and gasket making sure the gasket runs the full perimeter of the glass edge 5 Re install the retainer and eigh...

Страница 20: ...d or replace door gaskets Check that all outside connections are clear of any obstructions Check the exhaust system clean as needed Checkthatthepressureswitchconnectiontothefireboxisfreeofashorclearof...

Страница 21: ...he stove is in the Shut Down state waiting for the off button or for a 15 minute period after the stove was turned off or for the stove to cool down or for the door to be closed Flashing dash in Heat...

Страница 22: ...ass 1 3 88324 1 Rope Gasket 1 4 69762 Burnpot Assembly 1 5 80780 IR Remote 1 6 80455 High Temp Snapdisc 1 7 80886 Circuit Board Assy 1 8 88351 Channel Gasket 1 9 88118 Ignitor Flange Gasket 1 10 80869...

Страница 23: ...s are ordered Before contacting customer service write down the model number and the serial number of this unit That information can be found on the certification label attached to the back of the uni...

Страница 24: ..._____ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No ________________________...

Страница 25: ...2022 United States Stove Company 25 NOTES...

Страница 26: ...de rechange les informations contenues dans ce manuel vous aideront vous assurer que les bons articles sont command s Avant de contacter le service client notez le num ro de mod le et le num ro de s r...

Страница 27: ...1 4 69762 Assemblage Burnpot 1 5 80780 Ir distance 1 6 80455 Snapdisc temp rature lev e 1 7 80886 Assy de carte de circuit imprim 1 8 88351 Joint de canal 1 9 88118 Joint de bride d igniteur 1 10 8086...

Страница 28: ...nt deux fois par seconde Cela indique que le po le fonctionne normalement et qu une condition de temp rature excessive existe provoquant l arr t du combustible Indicateur de r glage du niveau de chale...

Страница 29: ...st me vis sans fin est bloqu ou il y a une vo te de combustible dans la tr mie qui emp che le combustible de s couler dans le syst me d approvisionnement vis sans fin PROBL ME CAUSE L allumeur automat...

Страница 30: ...rait 1 Une fois le radiateur refroidi retirez la porte du radiateur 2 Retirez le joint de corde de la porte puis les crous retenant le dispositif de retenue du verre en place 3 Tout en portant des gan...

Страница 31: ...p cialement con ue pour le type de chemin e utilis Un ramoneur qualifi peut fournir ce service Il est galement conseill d inspecter de nettoyer et si n cessaire de r parer la totalit du syst me avant...

Страница 32: ...int et la mention E2 s affiche sur l cran deux chiffres Le po le doit s arr ter compl tement avant de pouvoir tre red marr CHAMBRES INT RIEURES Pot de combustion Retirez et nettoyez p riodiquement le...

Страница 33: ...le voyant vert s allume 3 Ajustez la vitesse d alimentation au r glage souhait en appuyant sur le bouton Avance du niveau de chaleur Si le feu ne d marre pas dans 12 minutes appuyez sur Marche Arr t...

Страница 34: ...inf rieur 300 parties par million Les granul s mous contenant une quantit excessive de sciure de bois en vrac qui ont t ou sont mouill s r duiront les performances Rangez vos pellets dans un endroit...

Страница 35: ...entre le r glage pr s lectionn de la plage de chaleur d sir e 1 5 et le r glage de la plage de chaleur minimale de 1 Le T Stat n allumera ni ne teindra le po le Lorsque la temp rature ambiante souhai...

Страница 36: ...uand le syst me de chauffage est en mode manuel le thermostat en option ne contr lera pas correctement l unit Lorsque vous ajustez le r glage du ventilateur de tirage essayez seulement 1 r glage au de...

Страница 37: ...heat output will incrementally change on the bar graph starting from heat range 1 to heat range 5 C C F Button The C F button changes the two digit display from degrees Celsius to degrees Fahrenheit D...

Страница 38: ...rs un tuyau de connecteur de 6 pouces les illustrations ci dessous ne sont que des exemples Veuillez confirmer tous les codes du b timent locaux ou ragulations ayant comp tence avant de demander un in...

Страница 39: ...chutes de neige il est recommand que l installation soit plus grand que 3 pieds 0 91 m pour obtenir au dessus de la ligne de cong re Cette m me installation peut tre utilis e si votre chauffe eau est...

Страница 40: ...re garantie ECHAPPEMENT HORIZONTALES INSTALLATION 1 Localisez votre po le granul s dans un endroit qui r pond aux exigences de ce manuel mais dans une zone o il ne g ne pas la charpente de la maison l...

Страница 41: ...riodique du syst me d chappement Les coudes 90 degr s accumulent les cendres volantes et la suie r duisant ainsi le d bit d chappement et les performances du po le Chaque coude ou t r duit le potenti...

Страница 42: ...aide d un coupe feu de plafond certifi et d un chapeau de pluie Lors du d m nagement de votre maison mobile toute ventilation ext rieure doit tre enlev e pendant le d placement de la maison mobile Apr...

Страница 43: ...ment grand pour s tendre sur au moins 6 po 153 mm l avant 6 po 153 mm de chaque c t et 1 po 26 mm derri re le po le La protection du plancher doit s tendre sous et 2 po 51 mm de chaque c t du t de che...

Страница 44: ...DE PRISE ET NE COUPEZ PAS LA FICHE DE TERRE N ACHEMINEZ PAS LE CORDON LECTRIQUE SOUS DEVANT OU SUR LE PO LE NE FAITES PAS COURIR LE CORDON LECTRIQUE DANS LES ZONES DE PASSAGE ET NE LE COINCEZ PAS SOUS...

Страница 45: ...de c bles comme illustr tape 2 D ballez les meilleurs contr les de montage et de veiller ce que le faisceau de c blage illustr est x tape 3 Connecter les install s en usine faisceaux de c blage sur l...

Страница 46: ...n date d inspection du syst me de ventilation existant ___________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment aux i...

Страница 47: ...let peut effectuer le taux r el d alimentation en carburant et de br ler fois Taux d alimentation en carburant peut varier par autant que 20 Utiliser PFI carburant list pour de meilleurs r sultats Tem...

Страница 48: ...fortune lors de l installation de ce radiateur Contactez les responsables locaux du b timent ou des pompiers pour conna tre les permis les restrictions et les exigences d installation dans votre r gio...