background image

1.

Uncrate and/or unpack the heater, removing all packing
material, being careful not to dispose of the Parts Bag.

2.

Remove the following contents:

A. (4) Legs with nut and bolt package
B. (1) Lid with (1) Lid Lifter
C. (1) Shaker Grate
D. (1) Ash Door with (1) Slide Draft
E. (1) Feed Door

3.

Carefully lay the stove on its side, preferably on a soft
surface.  Note:  Cardboard shipping carton placed flat
works well for this application.

4.

Securely attach all four (4) legs to lower chamber using
nut and bolt package.

5.

Carefully return stove to upright position and place it in
desired location.

6.

Place lid in position on top plate.

7.

Position ash door with slide draft on front of lower
chamber.

8.

Place shaker grate in lower chamber.

Assembly and Installation

MINIMUM CLEARANCE

TO COMBUSTIBLE WALLS

FLOOR
PROTECTOR

(60" 

 MIN

.)

HEATER/FLOOR PROTECTOR LOCATION

FIG. 4

Place the heater on solid masonry or solid concrete. When
the heater is used on a combustible floor, use an Underwrit-
ers Listed floor protector. The floor protector must comply
with UL Standards.  The base should extend at least 18"
beyond the door side of the heater and should extend under
the flue pipe if it is elbowed towards a wall. (Fig. 4).

1.

The stove must have its own flue.  Do not connect this
unit to a chimney flue serving other appliances.

2.

After observing the clearances to combustibles, locate
your floor protector accordingly and carefully place the
stove in your selected location.  Install stove pipe ,
elbows and thimble as necessary, utilizing either a
recently cleaned and inspected masonry chimney or a
UL 103 HT Listed Residential Type and Building Heat
ing Appliance Chimney.

3.

If your chimney continues to draft excessively, then use
a Barometric Draft Regulator.

4.

Use three (3) sheet metal screws in each stove pipe and
/or elbow joint to firmly hold the stove pipe together.  Use
6" round black/blue stove pipe, not galvanized stove
pipe .

5.

Recheck illustrations Fig. 2 through 7 to be sure you
have the proper clearances shown from the stove and
the connector pipe to combustible surfaces.  NOTE:  If
a wall is only faced with brick or stone, consider it as a
combustible wall.

6.

DO NOT install this stove in a mobile home or trailer.

7.

If you have too much draft, then install a 6" cast iron
stove pipe damper in the first joint of the stove pipe.

CAUTION!

KEEP FURNISHINGS AND OTHER

COMBUSTIBLE MATERIALS

AWAY FROM THE HEATER.

FLOOR
PROTECTOR

10-1/4

38"

18"

FIGURE 2

FIGURE 3

42"

36"

39-1/2"

14-1/2"

FLOOR
PROTECTOR

NON- COMBUSTIBLE
CONSTRUCTION IN
ACCORDANCE WITH
NFPA 211

DASHED LINES
SHOW STRAIGHT
OUT CHIMNEY
CONNECTOR

28"

54"

36"

WRONG

RIGHT

WRONG

FIG. 5

4

(48")

(44")

(48")

(51-1/2")

Clearances in () are for Canada ONLY.

Содержание CSSU

Страница 1: ...TO ORDER REPAIR PARTS CORRECTLY KEEP IN A SAFE PLACE FOR FUTURE REFERENCE UNITED STATES STOVE COMPANY 227 Industrial Park Road P O Box 151 South Pittsburg TN 37380 423 837 2100 COMPANY U NITED STATES...

Страница 2: ...oval flue outlet and secure with metal screw Connect balance of stove pipe into a class A chimney Ill 3 Ill 3 Ill 3 Ill 3 Ill 3 15 19 5 21 6 36 FLOOR PROTECTOR SIDE VIEW FRONT VIEW STOVE DIMENSIONS FI...

Страница 3: ...our insurance company may be able to recommend a qualified inspector 6 Creosote or soot may build up in the chimney connector and chimney and can cause a house building fire Inspect the chimney connec...

Страница 4: ...connect this unit to a chimney flue serving other appliances 2 After observing the clearances to combustibles locate your floor protector accordingly and carefully place the stove in your selected loc...

Страница 5: ...e ceiling Fig 3 The pipe cannot extend into the chimney flue Fig 5 Seal each connector pipe joint with furnace cement Also seal the pipe at the chimney Use 3 sheet metal screws at each joint to make t...

Страница 6: ...have a chimney fire have your chimney inspected by a qualified person before using again Service Hints Do not expect a heater to draw It is the chimney that creates the draft Smoke spillage into the h...

Страница 7: ...5 89986 89987 89988 89989 89990 89991 89992 89993 89994 DESCRIPTION TOP PLATE UPPER CHAMBER FEED CHAMBER BURN CHAMBER LOWER CHAMBER BASE LEGS ASH DOOR SLIDE DRAFT SLIDE DRAFT KNOB SHAKER GRATE SPRING...

Страница 8: ...N WRITING ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE BACK OF THE HEATER WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION AS SHOWN IN THIS LIST 1 The PA...