2
CAUTION:
•
Power source not controlled by furnace main disconnect.
•
Respect all local and national codes when installing this unit.
•
This unit is not to be connected to a chimney flue serving
another appliance.
•
This unit is designed to burn solid hardwood only.
Combustible:
Wood
Flue Pipe Diameter:
6” (153cm)
Flue Pipe Type: (Standard Single Wall or Double Wall):
Black or Blued Steel 2100°F (650°C) Class “A”
Minimum Chimney Height:
12’
Maximum Log Length:
28”
Electrical:
120V, 60Hz, 3.4A per blower
Dimensions
Combustion Chamber:
Width x Depth:
17.4” X 28.3”
Volume:
Cubic Feet:
6.27 cubic feet
Door Opening: Width x Height:
12.625” X 12.5”
Weight (lbs):
509lbs
Specifications
CONGRATULATIONS!
You’ve purchased a heater from North America’s oldest manufacturer of wood burning products.
By heating with wood you’re helping to CONSERVE ENERGY!
Wood is our only Renewable Energy Resource. Please do your part to preserve our wood supply. Plant at least
one tree each year. Future generations will thank you.
This manual describes the installation and operation of the Clayton, 1661E
wood heater. This heater meets the 2016 U.S. Environmental Protection
Agency’s emission limits for wood heaters sold after May 15, 2016. Under
specific EPA test conditions this heater has been shown to deliver heat at a
rate of 33,438 to 77,456 BTU/hr. This heater achieved a particulate emissions
rate of 0.305 lbs/mmBTU when tested to method CSA B415.1-10 (*and an
overall efficiency of 61.9%.) The maximum overall heat output of this heater
was tested to be 104,720 BTU/hr.
This wood heater has a manufacturer-set minimum low burn rate that must not be altered. It is against federal
regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating
instructions in this manual.
The operation of this wood heater in a manner inconsistent with the owner’s manual will void your warranty and
is also against federal regulations.
This heater is designed to burn natural wood only. Higher efficiencies and lower emissions generally result when
burning air dried seasoned hardwoods, as compared to softwoods or to green or freshly cut hardwoods.
This wood heater needs periodic inspection and repair for proper operation. It is against federal regulations to
operate this wood heater in a manner inconsistent with operating instructions in this manual.
0215WH080E
37.79”
26.54”
48”
48.81”
48”
1220 mm
26.54”
675 mm
37.79”
26.54”
48”
48.81”
37.79”
960 mm
48.81”
1240 mm