GAS CONNECTION
NOTICE
CAUTION
IMPORTANT: Loosen the pipe adapter
on the flex tube before installing to the
system piping.
FIGURE 4. Gas Connection
CHECK GAS TYPE: The gas supply must be the same as stated on heater's rating plate. If the gas supply is
different, DO NOT INSTALL the heater. Contact your dealer for the correct model.
8
A qualified gas appliance installer must connect the fireplace to the gas supply.
Consult all local codes.
Use new black iron or steel pipe only. Internally tinned copper tubing can be used
in some areas when permitted by local codes. Only use pipe of 1/2" or greater
diameter to allow full gas volume to heater. Excessive pressure loss will occur if the
pipe is too small.
A manual shutoff valve, union and plugged 1/8" NPT pressure tapping point must be
installed upstream of the heater (FIGURE 4).
A sediment trap must be installed upstream of the heater to prevent moisture and
contaminants from passing through the pipe to the heater controls and burners.
Failure to do so could prevent the heater from operating reliably (FIGURE 4).
W
ARNING
TO HEATER
CONTROL VALVE
STAINLESS
FLEXIBLE TUBE
PIPE
COUPLING
PIPE
MANUAL
SHUTOFF VALVE
TEE JOINT
PIPE NIPPLE
CAP
SEDIMENT TRAP
Connecting directly to an unregulated propane/LPG tank can cause an
explosion.