6
© 2021 United States Stove Company
IMPROPER INSTALLATION
The use of other components other than stated herein
could cause bodily harm, heater damage, and void your
warranty. The manufacturer will not be held responsible
for damage caused by the malfunction of a stove due to
improper venting or installation.
FLOOR PROTECTION
This heater must have a non-combustible floor protector
(UL1618 ember protection) installed beneath it if the
floor is of combustible material.
US -
Floor protector should be UL listed or equal too,
needs to extend 6” to the front, 6” to each side, 1” to the
rear of the unit. Under and 2” beyond each side of the
cleanout tee if an interior vertical installation.
Canada -
Floor protector should comply with CAN/ULC
standards. Needs to extend 18” to the front, 8” beyond
each side of the unit.
A Back to Stove
U.S.A 1”
26mm
CAN 8” 204 mm
B Side to Stove
U.S.A 6” 153 mm
CAN 8” 204 mm
C Front to Stove
U.S.A 6” 153 mm
CAN 8” 204 mm
D Back to Flue
2”
51 mm
CLEARANCES
Your pellet stove has been tested and listed for installation
in residential, mobile home in accordance with the
clearances given below. For safety reasons, please adhere
to the installation clearances and restrictions. Any
reduction in clearance to combustibles may only be done
by means approved by a regulatory authority.
E Side Wall to Stove
10”
245 mm
F Side Wall to Vent Pipe
11-1/2”
292 mm
G Back Wall to Stove
11-7/8” 302 mm
H Back Wall to Vent Pipe
3”
76 mm
J Ceiling to Floor
84”
2134 mm
K Ceiling to Stove
53-7/8’ 1434 mm
L Side Wall to Stove
7-1/2”
191 mm
M Side Wall to Vent Pipe
11-1/4”
286 mm
N Back Wall to Vent Pipe
7-1/2”
191 mm
INSTALLATION