United States Stove Company Ashley AW3200E-P Скачать руководство пользователя страница 12

12

© 2023 United States Stove Company

OPERATION INSTRUCTIONS

wax, and similar substances to start a fire in an 

affected wood heater.

Burning these materials may result in the release 

of toxic fumes or render the heater ineffective 

and cause smoke. Deadwood lying on the forest 

floor  should  be  considered  wet  and  requires  full 

seasoning time. Standing deadwood can usually 

be considered to be about 2/3 seasoned. Smaller 

pieces of wood will dry faster. All logs exceeding 

6” in diameter should be split. The wood should 

not be stored directly on the ground. Air should 

circulate through the logs. A 24” to 48” air space 

should be left between each row of logs, which 

should be placed in the sunniest location possible. 

The upper layer of wood should be protected from 

the element but not the sides. A good indicator of 

if the wood is ready to burn is to check the piece 

ends. If cracks are radiating in all directions from 

the center then the wood should be dry enough to 

burn. If your wood sizzles in the fire, even though 

the surface is dry, it may not be fully cured and 

should be seasoned longer.

It  is  EXTREMELY  IMPORTANT  that  you  use  DRY 

WOOD only in your wood stove. The wood should 

have dried for 9 to 15 months, such that the 

humidity content (in weight) is reduced below 

20% of the weight of the log. It is very important to 

keep in mind that even if the wood has been cut 

for one, two, or even more years, it is not necessarily 

dry, if it has been stored in poor conditions. Under 

extreme conditions, it may rot instead of drying. 

This point cannot be overstressed; the vast majority 

of the problems related to the operation of a wood 

stove is caused by the fact that the wood used was 

too damp or had dried in poor conditions. These 

problems can be:
•  ignition problems
• 

creosote build-up causing chimney fires

•  low energy yield
•  blackened windows
•  incomplete log combustion

Do  not  burn  manufactured  logs  made  of  wax 

impregnated sawdust or logs with any chemical 

additives.

TESTING YOUR WOOD

•  When the stove is thoroughly warmed, place one 

piece of split wood (about five inches in diameter) 

parallel to the door on the bed of red embers.

• 

Keep  the  air  control  fully  open  and  close  the 

door. If the wood ignites within 90 seconds from 

the time it was placed in the stove, your wood is 

correctly dried. If ignition takes longer, your wood 

is damp.

•  If your wood hisses and water or vapor escapes 

at the ends of the piece, your wood is soaked 

or freshly cut (green). Do not use this wood in 

your stove. Large amounts of creosote could be 

deposited in your chimney, creating potential 

conditions for a chimney fire.

TAMPER WARNING

This wood heater has a manufacturer-set minimum 

low burn rate that must not be altered. It is against 

federal regulations to alter this setting or otherwise 

operate this wood heater in a manner inconsistent 

with operating instructions in this manual.

EFFICIENCIES

Efficiencies  can  be  based  on  either  the  lower 

heating value (LHV) or the higher heating value 

(HHV) of the fuel. The lower heating value is when 

water leaves the combustion process as a vapor, in 

the case of woodstoves the moisture in the wood 

being burned leaves the stove as a vapor. The higher 

heating value is when water leaves the combustion 

process completely condensed. In the case of 

woodstoves this would assume the exhaust gases 

are room temperature when leaving the system, 

and therefore calculations using this heating value 

consider the heat going up the chimney as lost 

energy.  Therefore,  efficiency  calculated  using  the 

lower heating value of wood will be higher than 

efficiency calculated using the higher heating value. 

The best way to achieve optimum efficiencies is to 

learn the burn characteristic of you appliance and 

burn well-seasoned wood. Higher burn rates are 

not always the best heating burn rates; after a good 

fire is established a lower burn rate may be a better 

option for efficient heating. A lower burn rate slows 

the  flow  of  usable  heat  out  of  the  home  through 

the chimney, and it also consumes less wood.

NOTICE INITIAL BURNS TO CURE PAINT

BECAUSE  OF  HIGH  OPERATING  TEMPERATURES, 

THIS  APPLIANCE  IS  COATED  WITH  A  SPECIAL 

HIGH TEMP PAINT WHICH REQUIRES A SERIES 

OF LOW TO MEDIUM BURNS TO FULLY CURE FOR 

DURABILITY AND A LIFETIME OF SERVICE.

Содержание Ashley AW3200E-P

Страница 1: ...nstallation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your new room heater Failure to follow instructions m...

Страница 2: ...ngth 18 458 mm Electrical 120VAC 0 55A 60Hz Dimensions DEPTH WIDTH HEIGHT Overall Depth x Width x Height 39 995 mm 24 612 mm 32 1 2 826 mm Combustion Chamber Width x Depth 18 5 16 X 22 1 4 466 mm X 56...

Страница 3: ..._________________________________ If no date of inspection of the existing chimney system __________________________________________________ COMMISSIONING Confirm Hearth Pad Installation as per Instal...

Страница 4: ...the back of the stove with the eight screws providedNOTE This bracket is included and is required for installation of the blower assembly ASH PAN The ash pan is located below the firebox PEDESTAL BAS...

Страница 5: ...D THIS ROOM HEATER SHALL NOT BE INSTALLED IN A FACTORY BUILT FIREPLACE US Stove highly recommends your stove be installed by a qualified NFI US or WETT Canada technician To find the nearest qualified...

Страница 6: ...led space a floor or a ceiling ForCanadianinstallations wherepassagethrough a wall or partition of combustible construction is desired the installation must conform to CAN CSA B365 A flue pipe crossin...

Страница 7: ...ure the unit to the floor In addition to the previously detailed installation requirements the heater must be electrically grounded to the steel chassis of the mobile home transportable building with...

Страница 8: ...cement Round flues are the most efficient The interior diameter of the chimney flue must be identical to the stove smoke exhaust A flue which is too small may cause draft problems while a large flue...

Страница 9: ...A 12 304 8 mm Clearance to Combustible Wall Member Using a minimum thickness 3 5 89 mm brick and a 5 8 15 9 mm minimum wall thickness clay liner construct a wall pass through The clay liner must confo...

Страница 10: ...flue liner METHOD D 2 50 8 mm Clearance to Combustible Wall Member Start with a solid pak listed factory built chimney section at least 12 304 mm long with insulation of 1 25 4 mm or more and an insi...

Страница 11: ...WITH SECONDARY TUBES FIBERBOARD OR INSULATION REMOVED WOOD STOVE UTILIZATION Your heating appliance was designed to burn well seasoned natural wood only no other materials should be burned Any type o...

Страница 12: ...ace one piece of split wood about five inches in diameter parallel to the door on the bed of red embers Keep the air control fully open and close the door If the wood ignites within 90 seconds from th...

Страница 13: ...of small pieces of cordwood NOTE Use smaller pieces of wood during start up and a high burn rate to increase the stove temperature 6 5 lbs Push both air control slides to the fully open position Light...

Страница 14: ...remove it to allow the tube to be removed and replaced BLOWER OPERATION The variable speed blower circulates air warmed by the firebox into the living area to distribute the heat more evenly The blow...

Страница 15: ...3 to 4 inches deep in your firebox or ash pan and when the fire has burned down and cooled remove excess ashes Leave an ash bed approximately 1 inch deep on the firebox bottom to help maintain a hot...

Страница 16: ...stomer service by phone 1 800 750 2723 Ext 5051 or Email parts usstove com Model Information Model Number Serial Number CHIMNEY MAINTENANCE Never wash the glass with a product that may scratch Use a s...

Страница 17: ...f the appliance plus the 200 mm 8 in required on each side of the appliance without a door Where an appliance is installed less than 200 mm 8 in from a wall the ember pad need only extend to the base...

Страница 18: ...NTS WILL VOID THE WARRANTY To order parts Call 1 800 750 2723 Ext 5051 or Email to parts usstove com Key Part Description Qty 1 892268 Heat Shield Left 1 2 892269 Heat Shield Rear 1 3 892267 Heat Shie...

Страница 19: ...r Board Top 2 14 88193 Kao Wool 1 2 1 3 4 5 8 6 7 9 Key Part Description Qty 1 891135 Spring Handle 1 2 892266 Handle Assembly 1 3 40596 Ponderosa Cast Door 1 4 88082 Rope Gasket 3 4 3 5 ft 5 892270 G...

Страница 20: ...Date ______________________ Engineer Name ________________________________ License No _____________________________________ Company ______________________________________ Telephone No _______________...

Страница 21: ...icles Remplac _____________________________ Service de 07 Date _____________________ Nom de l ing nieur ____________________________ N de licence __________________________________ Compagnie _________...

Страница 22: ...1 2 1 3 4 5 8 6 7 9 Cl Partie La Description Qt 1 891135 Poign e ressort 1 2 892266 Assemblage de la poign e 1 3 40596 Porte coul e 1 4 88082 Joint de corde 3 4 po 3 5 pi 5 892270 Verre porte de la ch...

Страница 23: ...ription Qt 1 892268 Bouclier thermique gauche 1 2 892269 Bouclier thermique arri re 1 3 892267 Bouclier thermique droite 1 4 892278 Garniture sup rieure 1 5 892279 Garniture de foyer 1 6 69912 Tiroir...

Страница 24: ...rte Lorsqu un appareil est install moins de 200 mm 8 po d un mur le tampon de braises ne doit s tendre que jusqu la base du mur Un tampon de braises ne doit pas tre plac sur un tapis moins que le tamp...

Страница 25: ...nt vendus Le verre ne doit tre lav qu froid ENTRETIEN DES JOINT AVERTISSEMENT N UTILISEZ JAMAIS LE PO LE SANS JOINT OU AVEC UN CASS DES DOMMAGES AU PO LE OU L INCENDIE DE LA MAISON PEUVENT EN R SULTER...

Страница 26: ...re POUR VITER LA CONSTRUCTION DE CR OSOTE Br lez toujours du bois sec Cela permet des br lures propres et des temp ratures de chemin e plus lev es donc moins de d p t de cr osote Laissez le contr le d...

Страница 27: ...visible et br lera mal CONDUITS D AIR Les conduits d air assembl s dans cette unit sont con us pour offrir un m lange pr cis d air secondaire et assurer une plus grande efficacit Tout dommage ou d t r...

Страница 28: ...eaux de bois de corde REMARQUE Utilisez de plus petits morceaux de bois pendant le d marrage et un taux de combustion lev pour augmenter la temp rature du po le 6 5 lbs Poussez les deux glissi res de...

Страница 29: ...ises rouges Gardez la commande d air compl tement ouverte et fermez la porte Si le bois s enflamme dans les 90 secondes suivant le moment o il a t plac dans le po le votre bois est correctement s ch S...

Страница 30: ...E PO LE OU N IMPORTE O DANS LES D GAGEMENTS DES SURFACES COMBUSTIBLES SP CIFI ES POUR CET APPAREIL NE JAMAIS FAIRE FONCTIONNER AVEC DES TUBES SECONDAIRES UN CARTON DE FIBRE OU UNE ISOLATION RETIR E UT...

Страница 31: ...t le d acier Conduit de chemin e Conduit de raccordement Le d gagement minimum de la chemin e aux supports en t le d acier et aux mat riaux combu ibles e de 5 cm 2 po 50 8 mm Deux canaux d a ration de...

Страница 32: ...n rev tement en argile d une paisseur minimale de 5 8 po 15 9 mm construisez un passage travers la paroi Le rev tement en argile doit tre conforme l ASTM C315 Sp cification standard des rev tements r...

Страница 33: ...ques d argile r fractaire de tuiles m talliques ou d argile scell es avec du ciment r fractaire Les conduits ronds sont les plus efficaces Le diam tre int rieur du conduit de chemin e doit tre identiq...

Страница 34: ...ONC TRE UN TYPE HT 2100 F UTILISEZ UN AGRESSEUR TINCELLES LE PO LE DOIT TRE FIX LA STRUCTURE DE LA MAISONS MOBILES B TIMENTS PORTATIF UTILISEZ LES DEUX 2 TROUS AU FOND DU PI DESTAL DE LA RADIATEUR POU...

Страница 35: ...de fum e Le raccord de chemin e ne doit pas traverser un grenier ou un espace sur le toit un placard ou un espace dissimul similaire un plancher ou un plafond Pour les installations canadiennes o le...

Страница 36: ...HAUFFAGE NE DOIT PAS TRE INSTALL DANS UN FOYER CONSTRUIT EN USINE Nous recommandons que nos produits de foyer des au Canada par le programme de formation technique en nergie du bois WETT CERTIFI US St...

Страница 37: ...udes Fixez l ensemble l arri re du po le avec les huit vis fournies REMARQUE Le support du ventilateur est inclus dans le cas o un ventilateur est demand pour cette unit CENDRIER Le cendrier est situ...

Страница 38: ...tion du syst me de chemin e existant _________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment aux instructions d installation C...

Страница 39: ...ntr que cet appareil de chauffage fournit de la chaleur des taux allant de 19 778 67 992 Btu h avec 1 3 g h et 71 d efficacit Remarque Les cotes BTU mentionn es ci dessus sont bas es sur le protocole...

Страница 40: ...on dans votre r gion NE JAMAIS UTILISER CE PRODUIT SANS SURVEILLANCE MISE EN GARDE Veuillez lire l int gralit de ce manuel avant d installer ou d utiliser votre nouveau radiateur Le non respect des in...

Отзывы: